교류 저전압 표준용 교류-직류 변환기의 입력임피던스 평가기술 개발
權聖遠(Sung-Won Kwon),鄭在甲(Jae Kap Jung),李相和(Sang-Hwa Lee),金紋奭(Myungsoo Kim),金漢俊(Han Jun Kim) 대한전기학회 2008 전기학회논문지 Vol.57 No.2
An AC-DC transfer standard(TS) is used for the AC voltage standard in the range of 2 ㎷ to 1000 V below 1 ㎒. Micro-potentiometer(μPot) is used to evaluate the ac-dc transfer difference(ADD) of the TS below 200 ㎷ range. The ADD of the TS were changed by the loading effect caused from the input impedance change of the TS depend on frequency. An input impedance evaluation technique of the TS using μPot has been developed.
權聖遠(Sung-Won Kwon),鄭在甲(Jae-Kap Jung),李相和(Sang-Hwa Lee),金明壽(Myungsoo Kim) 대한전기학회 2006 전기학회논문지C Vol.55 No.6
A accurate potential transformer(PT) with the nominal ratio errors in the wide range of - 9 % to + 11 % has been developed. The developed wide ratio error PT can be used to evaluate the linearity of the PT comparator by comparing both the theoretical values as standard values and experimental values of the PT. The new method has been successfully applied for calibration and correction in the PT comparator including very low ratio error values from ± 0.005 % to ± 0.3 % belonging to industry.
權聖遠(Sung-Won Kwon),鄭在甲(Jae-Kap Jung),李相和(Sang-Hwa Lee),金紋奭(Mun-Seog Kim),金明壽(Myungsoo Kim) 대한전기학회 2006 전기학회논문지C Vol.55 No.6
Standard current transformer(CT) with the nominal ratio errors in the range of - 10 % to + 10 % has been developed. Linearity of the CT ratio error measuring system (CT comparator) has been tested by using wide ratio error standard current transformer(WRE CT). The developed WRE CT can be used to evaluate the linearity of the CT comparator by comparing both the theoretical values and experimental values of the WRE CT. The developed method has been successfully applied for calibration and correction in the CT comparator belonging to industry.
SJTC 및 MJTC를 활용한 교류전압 국가표준의 개발 및 확립
권성원(Sung-Won Kwon),김문석(Mun-Seog Kim),정재갑(Jae Kap Jung),김규태(Kyu Tae Kim) 대한전기학회 2010 대한전기학회 학술대회 논문집 Vol.2010 No.7
교류전압표준은 교류 및 직류 전압에 대등하게 응답하는 열전변환기를 매개표준기로 활용하여 직류전압표준으로부터 유도한다. 교류전압표준기로 활용하기 위하여 4 V 이하의 박막형 다중접합 열전변환기(MJTC)를 설계 제작하고 교류-직류 변환오차를 평가하였으며, 국제비교측정을 통하여 국제적 동등성을 확보하였다. 단일접합 열전변환기(SJTC)를 활용하여 교류전압표준을 1000 V까지 확장하는데, 이들의 교류-직류 변환오차는 4-V MJTC를 기준으로 삼아 step-up 측정으로 결정한다. 여기서는 열전변환기를 활용한 교류전압표준 확립현황과 교류-직류변환 차이 측정시스템 및 측정불확도를 기술하였으며, 측정능력을 나타내는 교류전압표준의 불확도는 주파수 10 ㎐ ~ 1㎒, 전압 100 ㎷ ~ 1 ㎸ 범위에서 (3 ~ 50) ㎶/V으로써 국제적 수준이다.