http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
흉부 팬텀 CR 영상의 화질평가 및 피폭선량 경감에 관한 연구
김흥태,권수일,박일영,정환,Kim, Heung-Tae,Gwon, Su-Il,Park, Il-Yeong,Jeong, Hwan 대한디지털의료영상학회 1998 대한디지털의료영상학회논문지 Vol.4 No.1
With this experiment we have conclusion as follows. $\cdot$ Total FCR-9501 are 8 units. $\cdot$ All hospitals under study are conducting the high kvp radiographing with 115-120kvp and 4$\sim$10mAs. $\cdot$ The mean value of the chest exposure was 0.524$\sim$0.301mGy. $\cdot$ The percentage of the absorber finding from phantom was more the 85% with a range of 100$\sim$136 kvp. $\cdot$ The mean dose from phantom was 0.990mGy with 124 kvp and 16 mAs. $\cdot$ There is no difference in the amount of information due to the change of kvp and mAs, but some coarseness of images can be seen in the magnified images. $\cdot$ The resolving power was about 1.5/mm. $\cdot$ The increase and decrease of 10$\sim$30 kvp from common kvp has not influenced on the amount of information. $\cdot$ The exposure could be reduced by 0.170$\sim$0.570mGy.
CR장치와 일반 촬영 장치에서 피폭선량 측정과 촬영조건표 작성에 관한 연구
김흥태,권수일,권달관,김화곤,Kim, Heung-Tae,Gwon, Su-Il,Gwon, Dal-Gwan,Kim, Hwa-Gon 대한디지털의료영상학회 1997 대한디지털의료영상학회논문지 Vol.3 No.1
We tried to find any factor to reduce the exposure dose with ST-VA type generator which has the higher exposure dose. The guideline recommended by the provisions of IAEA regulation is being used at the time of radiation exposure and almost of those equipments used for this study had less amount of doses than those in the guideline. The FCR may be possible to decrease a certain amount of dose with effective applications of it's automatic image compensation utilities and the verifying function in PACS. Next time, it is required to add a great number of hospitals for wide range of studios and measurements, and make standard exposure Control table which will bing in practice, material decrease of dose volumes when radiation exposure.
Flusilazole의 훈증 효과에 의한 양파검은곰팡이병균(Aspergillus niger)의 포자 형성 억제
김흥태,박세원,최경자,김진철,조광연,Kim, Heung-Tae,Park, Se-Won,Choi, Gyung-Ja,Kim, Jin-Cheol,Cho, Kwang-Yun 한국식물병리학회 2002 식물병연구 Vol.8 No.2
1998년 전남 신안군의 양파 상온 저장고에서 발생한 검은색의 곰팡이는 검은곰팡이병을 일으키는 Aspergillusniger로 동정되었다. A. niger AnYD-1은 3$0^{\circ}C$에서 균사생장, 포자발아 그리고 양파에 대한 병원성이 가장 양호하였다. PDA 배지 상에서 실시한 in vitro의 실험에서 flusilazole과 hexaconazole은 A. niger AnYD-1의 균사 생장 억제 효과는 적었지만, 병원균에 살균제를 직접 처리하지 않고 증기 상태로 처리하였을 때 포자의 형성을 강하게 억제하는 특이적 인 훈증효과를 보였다. Flusilazole과 hexaconazole의 훈증의 효과는 사용하는 용매, 처리 농도와 배양 온도에 따라서 차이가 있었다. Dimethylsulfoxide와 dimethylformamide를 용매로 사용하였을 때 가장 높은 효과가 나타났으며, 고온에서 배양할수록 포자형성 억제 효과가 크게 나타났다. In 1998, a pathogen isolated from infected onions was identified as Aspergillus niger. At 3$0^{\circ}C$, A. niger AnYD-1 showed the best mycelial growth, spore germination, and high pathogenicity to onions. In spite of the weak inhibitory effect of flusilazole and hexaconazole on the mycelial growth on PDA, they showed the specific inhibitory activity against the formation of spores in the vapour phase. With flusilazole and hexaconazole, the effects of the solvent, the applied concentration and the incubating temperature on the activities inhibiting the spore formation were confirmed. Their inhibitory effect on the spore formation in vapour phase was excellent by solving them with dimethylsulfoxide and dimethylformamide among tested solvents, and applying them at high temperature such as 30~35$^{\circ}C$.
김흥태,이영신,박영문,Kim, Heung-Tae,Lee, Young-Shin,Park, Young-Moon 한국전산구조공학회 2011 한국전산구조공학회논문집 Vol.24 No.3
본 논문에서는 유한요소모델을 사용하여 원자력 발전용 해수여과장치에 대한 동적 내진해석을 수행하였다. 장치의 검증을 위해서 운전기준지진(Operating Basis Earthquake, OBE)과 안전정지지진(Safe Shutdown Earthquake, SSE)이 설계하중으로 작용하였을 때 부재에 미치는 영향을 평가하였다. 해석대상은 유한요소법을 사용하여 수학적 모델링을 완성하였고, 층응답스펙트럼(Floor Response Spectrum, FRS)에 따른 지진하중과 사하중 등을 적용하여 해석을 수행하였다. 해석된 해수여과장치의 최대변위는 OBE 조건에서 2.5mm이고, SSE 조건에서 최대변위는 4.6mm이다. 최대응력은 OBE 조건에서 24MPa, SSE 조건에서 44MPa이며, 이 값은 재료의 항복강도의 각각 18%, 27% 수준이다. 이에 따라 지진하중 조건에 따른 해수여과장치의 구조적 안전성이 제시되었다. In this study, the seismic analysis of traveling sea water screen for nuclear power plant was performed using finite element model. For qualification of traveling sea water screen, the response spectrum analysis was performed using the given operating basis earthquake(OBE) and safe shutdown earthquake(SSE) floor response spectrum. Dynamic analysis of water sea traveling screen was performed using finite element method. The analytical maximum displacements of traveling sea water screen were 2.5 mm under OBE condition and 4.6 mm under SSE condition. The maximum stresses of traveling sea water screen were 24 MPa under OBE condition and 44 MPa under SSE condition, that this results were 18 %, 27% of yield strength of material. Thus, it can shown that the structural integrity of traveling sea water screen has a stable structure for seismic load conditions.