http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Youk, Ji-Ho,Jo, Won-Ho The Korean Fiber Society 2001 Fibers and polymers Vol.2 No.2
The effects of rate of phase separation to ester interchange reactions and the repulsive pair interaction energy on the phase behavior in a phase-separated immiscible polyester blend are investigated using a Monte Carlo simulation method. The time evolution of structure factor and the degree of randomness are monitored as a function of homogenization time. When the phase separation is dominant over ester interchange reactions, the domain size slowly increases with homogenization time. However, when the pair interaction becomes less repulsive, the domain size does not significantly change with homogenization time. On the other hand, when ester interchange reactions are dominant over the phase separation, the homogenization proceeds without a change in the domain size. The higher the extent of phase separation, the lower the increasing rate of the DR. However, when the phase separation is sufficiently dominant, the effect of the extent of phase separation on the increasing rate of the degree of randomness become less significant.
전자선 조사를 통한 편광필름용 아크릴계 고분자의 가교화 반응에 대한 연구
육지호(Ji Ho Youk),박정진(Jung Jin Park),최홍준(Hong June Choi),고환순(Hwan Soon Ko),정은환(Eun Hwan Jeong) 한국고분자학회 2012 폴리머 Vol.36 No.3
전자선 조사 방법을 이용하여 편광필름용 아크릴계 고분자를 가교화시킨 후 이의 점착 특성을 평가하였다. 아크릴 공중합체는 n-butylacrylate(BA), 2-hydroxyethyl methacrylate(HEMA), acrylic acid(AA)를 기본 단량체로 하여 다양한 조성으로 중합하였다. 아크릴 공중합체를 25 μm 두께로 PET 이형필름에 코팅한 후 편광필름에 합지 하고 그 위에 전자선을 조사하여 아크릴 공중합체의 가교화 반응을 진행하였다. 모든 아크릴 공중합체는 조사선량 50 kGy에서 93% 이상의 높은 젤분율을 보였으며, 아크릴 공중합체에 도입된 HEMA 단위가 많을수록 높은 가교밀 도를 보였다. BA/HEMA/AA(89.5/10/0.5 w/w/w)의 단량체 공급비로 중합된 아크릴 공중합체에 50 kGy로 전자선 을 조사하여 얻어진 아크릴 점착제가 가장 우수한 박리력, 내크리프성, 내구신뢰성, 내열빛샘 특성을 보였다. 전자 선 조사를 이용한 편광필름용 아크릴계 점착제의 제조 방법을 적용하면 액정 표시장치용 편광필름의 생산성 및 작 업성을 크게 개선할 것으로 기대된다. New pressure sensitive adhesives (PSAs) for polarizer film were prepared by electron beam (e-beam) radiation to acrylic copolymers, and their adhesive properties were investigated. The acrylic copolymers were synthesized by free radical polymerization of n-butylacrylate (BA), 2-hydroxyethyl methacrylate (HEMA), and acrylic acid (AA). The acrylic copolymers were coated on PET release films to a thickness of 25 μm, laminated to polarizer films, and then radiated with e-beam at room temperature. Gel fractions of all the acrylic copolymers after e-beam radiation at 50 kGy were higher than 93%, and their crosslinking densities were increased with increasing the content of HEMA units. PSA prepared by e-beam radiation of acrylic copolymer synthesized with a feed ratio of BA/ HEMA/AA=89.5/10/0.5 (w/w/w) at a dose of 50 kGy exhibited the best adhesion performances in terms of peel strength, creep resistance, durability and reliability, and light leakage. It is expected that the preparation method of PSAs via e-beam irradiation will improve the producibility and workability of polarizer film for liquid crystal display.
Youk, Shin-Young,Lee, Jee-Ho,Park, Ji-Man,Heo, Seong-Joo,Roh, Hyun-Ki,Park, Eun-Jin,Shin, Im Hee The Korean Academy of Prosthodonitics 2014 The Journal of Advanced Prosthodontics Vol.6 No.5
PURPOSE. This study aims to investigate the degree of subjective pain and the satisfaction of patients who have undergone an implant treatment using a computer-guided template. MATERIALS AND METHODS. A survey was conducted for 135 patients who have undergone implant surgery with and without the use of the computerguided template during the period of 2012 and 2013 in university hospitals, dental hospitals and dental clinics that practiced implant surgery using the computer-guided template. Likert scale and VAS score were used in the survey questions, and the independent t-test and One-Way ANOVA were performed (${\alpha}=.05$). RESULTS. The route that the subjects were introduced to the computer-guided implant surgery using a surgical template was mostly advices by dentists, and the most common reason for which they chose to undergo such surgery was that it was accurate and safe. Most of them gave an answer that they were willing to recommend it to others. The patients who have undergone the computer-guided implant surgery felt less pain during the operation and showed higher satisfaction than those who have undergone conventional implant surgery. Among the patients who have undergone computer-guided implant surgery, those who also had prior experience of surgery without a computer-guided template expressed higher satisfaction with the former (P<.05). CONCLUSION. In this study, it could be seen that the patients who have undergone computer-guided implant surgery employing a surgical template felt less pain and had higher satisfaction than those with the conventional one, and the dentist's description could provide the confidence about the safety of surgery.