RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCIESCOPUSKCI등재
      • SCOPUSKCI등재

        Surface Transition by Solvent Washing Effects and Biological Properties of Metal Treated Activated Carbons

        Oh, Won-Chun Korean Chemical Society 2004 Bulletin of the Korean Chemical Society Vol.25 No.5

        Metal treated activated carbons are prepared using various metals. Adsorption behaviors, morphologies, as well as antibacterial effects of metal treated samples are compared before and after solvent washing. Adsorption isotherms are used to characterize the porous structure of metal treated activated carbons before and after the solvent washing with acetone or ethyl alcohol. From these data, it is noticed that the changes in physicochemical properties of metal treated activated carbons depend on the solvents employed. Similar results are observed from BET data obtained from nitrogen adsorption isotherms. From scanning electron microscopy (SEM) studies, the changes in shape and size of metal particles are observed after the samples are washed with solvents. These changes result in different blocking effects, which, in turn, affect the adsorption behavior of metal treated activated carbons. X-ray diffraction (XRD) patterns of the samples treated with different metals are different each other. High intense sharp peaks attributed to metals are observed from silver treated samples, while the peaks are not observed from copper treated samples. To compare thermodynamic behavior of metal treated activated carbons washed with different type of solvents, differential scanning calorimetric (DSC) analysis is carried out. The analysis shows similar endothermic curves for all of the samples. Finally, antibacterial effects of metal treated activated carbon against Escherichia coli are discussed. Comparing the effects among the metals employed, highest effects are obtained from Cd, while lowest effects are obtained from Cu. Antibacterial activity becomes higher with the increase of the amount of metals treated, Optimum concentrations of metals to treat activated carbons, obtained from a shake flask test, are known to be 0.4, 0.1, and 0.6 moles for Ag, Cd, and Cu, respectively.

      • SCOPUSKCI등재

        Silver Loading Effect for the Activated Carbon Fibers Pre-treated with Acid

        Oh, Won-Chun,Yum, Min-Hyung Korean Chemical Society 2004 Bulletin of the Korean Chemical Society Vol.25 No.8

        The adsorption isotherms of N2 onto the metallic silver treated activated carbon fiber samples after acid treatment are Type I with a small amount of capillary condensation hysteresis. Increasing amount of acid treatment leads to a decrease in SBETs and external surface area. But, micropore volume and average pore diameter are presented in constant regular values with increasing amount of sulfuric acid treatment. SEM observes the surface morphology and crystal grown state of metal on the fiber surface. The results of EDX of Ag-activated carbon fiber pre-treated with acid show the spectra corresponding to almost all samples rich in silver with increasing the amount of acid treated. The FT-IR spectra of Ag-activated carbon fiber show that the acid pre-treatment is consequently associated with the homogeneous dispersion of metal with the increased surface acidity of the activated carbon fiber. The type and quality of oxygen groups are determined with Boehm titration method. From the those results, a positive influence of the acidic groups on the carbon fiber surface by acid treatment is also demonstrated by an increase in the contents of metallic silver with increasing of acidic groups.

      • SCOPUSKCI등재
      • SCIEKCI등재

        Validation of Human HazChem Array Using VOC Exposure in HL-60 Cells

        Oh, Moon-Ju,Kim, Seung-Jun,Kim, Jun-Sub,Kim, Ji-Hoon,Park, Hye-Won,Kim, Youn-Jung,Ryu, Jae-Chun,Hwang, Seung-Yong The Korean Society of Toxicogenomics and Toxicopro 2008 Molecular & cellular toxicology Vol.4 No.1

        Volatile Organic Compounds (VOCs) have been shown to cause nervous system disorders through skin contact or respiration, and also cause foul odors even at low densities in most cases. Also, as a compound itself, VOCs are directly harmful to the environment and to the human body, and may participate in photochemical reactions in air to create secondary pollutants. In this study, HL-60 cells were treated with volatile organic compounds, including ethylbenzene and trichloroethylene, at a value of $IC_50$. Then, the in house-prepared Human HazChem arrayer was utilized in order to compare the gene expression between the two VOCs. After hybridization, 8 upregulated genes and 8 downregulated genes were discovered in the HazChem array. The upregulated genes were identified as SG15, TNFSF10, PRNP, ME1, NCOA4, SRXN1, TXNRD1, and XBP1. The downregulated genes were identified as MME, NRF1, PRARBP, CALCA, CRP, BAX, C7 or f40, and FGFR1. Such results were highly correlated with the quantitative RT-PCR results. The majority of the 16 genes were related with the characteristics of VOCs, including respiratory mechanism, apoptosis, and carcinogenesis-associated genes. Our data showed that our human HazChem array can be used to monitor hazardous materials via gene expression profiling.

      • SCIESCOPUSKCI등재

        Surface Properties of HCl Modified Ag-ACFs

        Oh, Won-Chun,Ko, Young-Shin Korean Carbon Society 2005 Carbon Letters Vol.6 No.4

        Silver impregnated activated carbon fibers were post-modified using hydrochloric acid. Adsorption behaviors, SEM morphologies, and functional groups for the silver impregnated ACFs were compared with those of post-modified ACFs. Adsorption isotherms were used to characterize $S_{BET}$, the pore structure and volume of silver-activated carbon fibers (ACFs) before and after acid post-treatment. In order to the reveal the causes of the differences surface states after the samples were washed with hydrochloric acid, outer surface and pore structure were investigated by SEM. And the type and quality of various functional groups were studied from FT-IR spectra and Boehm titration method. Finally, the quantitative properties in silver contents were also examined by EDX spectra.

      • KCI등재

        Adsorption properties and metal growth aspects on the surface of activated carbon monolith electrochemically deposited with Ag

        Oh, Won-Chun,Lim, Chang-Sung The Korea Association of Crystal Growth 2004 韓國結晶成長學會誌 Vol.14 No.2

        The electrochemical adsorption of the Ag ions from aqueous solution on pelletized activated carbon monolith was investigated over wide range of operation time. The adsorption capacities of pelletized activated carbon monolith are associated with their internal porosity and are related properties such as surface area, pore size distribution. The chemical industry generates wastewater that contains toxic matters like heavy metals in small concentrations so that their economic recovery is not feasible. But, the method using activated carbon monolith can be used to withdrawal of heavy metals in waste water. After the electrochemical treatment, the quantitative properties in Ag ion solutions are also examined by pH concentration and studied elemental analysis by ICP-Atomic Emission Spectrometer and Energy Disperse X-ray (EDX) spectra. It is consider that the pH is very important factor at the reason of water pollutant with increasing acidity in industrial field. The result of quantitative analysis using Inductively Coupled Plasma-Atomic Emission Spectrometer of metal after electrochemical reaction in Ag ions solution depending on time are shown that the amount of Ag ions deposited was decreased with growth of Ag particles on the carbon surfaces as increasing electrochemically treated time. And, surface morphologies are investigated by scanning electron microscopy (SEM) to explain the changes in adsorption properties.

      • SCIESCOPUSKCI등재

        Deintercalation and Thermal Stability of Na-graphite Intercalation Compounds

        Oh, Won-Chun Korean Carbon Society 2001 Carbon Letters Vol.2 No.1

        Na alloyed graphite intercalation compounds with stage 1 and 2 were synthesized using the high temperature and pressure technique. Thermal stability and staging transitions of the compounds were investigated depending on heating rates. The thermal stability and temperature dependence of the deintercalation compounds were characterized using differential scanning calorimeter (DSC) analyzer. Enthalpy of formations were confirmed at temperatures between 25 and $500^{\circ}C$, depending on the various heating rates. The structure ions and interlayer spaces of the graphite were identified by X-ray diffraction (XRD). Diffractograms of stages with non-integral (00l) values were obtained in the thermal decomposition process, and stacking disorder defects and random stage modes were observed. The average value of the interlayer C-C bond lengths were found approximately $2.12{\AA}$ and $1.23{\AA}$ from the diffractions. Based on the stage transition, the degree of the deintercalaton has a inverse-linear relationship against the heating rate.

      • SCOPUSKCI등재
      • SCOPUSSCIEKCI등재

        Incidence and Risk Factors of Acute Postoperative Delirium in Geriatric Neurosurgical Patients

        Oh, Yoon-Sik,Kim, Dong-Won,Chun, Hyoung-Joon,Yi, Hyeong-Joong The Korean Neurosurgical Society 2008 Journal of Korean neurosurgical society Vol.43 No.3

        Objective: Postoperative delirium (POD) is characterized by an acute change in cognitive function and can result in longer hospital stays, higher morbidity rates, and more frequent discharges to long-term care facilities. In this study, we investigated the incidence and risk factors of POD in 224 patients older than 70 years of age, who had undergone a neurosurgical operation in the last two years. Methods: Data related to preoperative factors (male gender, >70 years, previous dementia or delirium, alcohol abuse, serum levels of sodium, potassium and glucose, and co-morbidities), perioperative factors (type of surgery and anesthesia, and duration of surgery) and postoperative data (length of stay in recovery room, severity of pain and use of opioid analgesics) were retrospectively collected and statistically analyzed. Results: POD appeared in 48 patients (21.4%) by postoperative day 3. When we excluded 26 patients with previous dementia or delirium, 17 spontaneously recovered by postoperative day 14, while 5 patients recovered by postoperative 2 months with medication, among 22 patients with newly developed POD. The univariate risk factors for POD included previously dementic or delirious patients, abnormal preoperative serum glucose level, pre-existent diabetes, the use of local anesthesia for the operation, longer operation time (>3.2 hr) or recovery room stay (>90 mini, and severe pain (VAS>6.8) requiring opioid treatment (p<0.05). Backward regression analysis revealed that previously dementic patients with diabetes, the operation being performed under local anesthesia, and severe postoperative pain treated with opioids were independent risk factors for POD. Conclusion: Our study shows that control of blood glucose levels and management of pain during local anesthesia and in the immediate postoperative period can reduce unexpected POD and help preventing unexpected medicolegal problems and economic burdens.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼