RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        Metallic Stent Placement in Hemodialysis Graft Patients after Insufficient Balloon Dilation

        Huei-Lung Liang,Huay-Ben Pan,Yih-Huie Lin,Chiung-Yu Chen,Hsiao-Min Chung,Tung-Ho Wu,Kang-Ju Chou,Pin-Hong Lai,Chien-Fang Yang 대한영상의학회 2006 Korean Journal of Radiology Vol.7 No.2

        Objective: We wanted to report our experience of metallic stent placement after insufficient balloon dilation in graft hemodialysis patients. Materials and Methods: Twenty-three patients (13 loop grafts in the forearm and 10 straight grafts in the upper arm) underwent metallic stent placement due to insufficient flow after urokinase thrombolysis and balloon dilation. The indications for metallic stent deployment included 1) recoil and/or kinked venous stenosis in 21 patients (venous anastomosis: 17 patients, peripheral outflow vein: four patients); and 2) major vascular rupture in two patients. Metallic stents 8 10mm in diameter and 40 80 mm in length were used. Of them, eight stents were deployed across the elbow crease. Access patency was determined by clinical follow-up and the overall rates were calculated by Kaplan-Meier survival analysis. Results: No procedure-related complications (stent fracture or central migration) were encountered except for a delayed Wallstent shortening/migration at the venous anastomosis, which resulted in early access failure. The overall primary and secondary patency rates ( standard error) of all the vascular accesses in our 23 patients at 3, 6, 12 and 24 months were 69% 9 and 88% 6, 41% 10 and 88% 6, 30% 10 and 77% 10, and 12% 8 and 61% 13, respectively. For the forearm and upper-arm grafts, the primary and secondary patency rates were 51% 16 and 86% 13 vs 45% 15 and 73% 13 at 6 months, and 25% 15 and 71% 17 vs 23% 17 and 73% 13 at 12 months (p = .346 and .224), respectively. Conclusion: Metallic stent placement is a safe and effective means for treating peripheral venous lesions in dialysis graft patients after insufficient balloon dilation. No statistically difference in the patency rates between the forearm and upper-arm patient groups was seen.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼