        Application of O-RADS US combined with MV-Flow to diagnose ovarian-adnexal tumors

        Linlin Ruan,Hui Liu,Hong Xiang,Yongkang Ni,Yuling Feng,Huili Zhou,Mengtong Qi 대한초음파의학회 2024 ULTRASONOGRAPHY Vol.43 No.1

        Purpose: This study aimed to explore the application of Ovarian-Adnexal Reporting and Data System Ultrasound (O-RADS US) combined with MV-Flow (Samsung Medison Co., Ltd.) to diagnose ovarian-adnexal masses.Methods: A total of 112 ovarian-adnexal masses (81 benign and 31 malignant) from 105 consecutive patients were analyzed. The O-RADS US and vascular index from MV-Flow (VI<sup>MV</sup>) were measured and compared with the reference standard. O-RADS US and MV-Flow were tested for consistency.Results: Receiver operating characteristic curves were drawn for O-RADS US, MV-Flow, and their combination. The combined methods had the largest area under the curve (0.955), followed by O-RADS US (0.929) and MV-Flow (0.923). A mass was considered malignant when the O-RADS US classification was 5 and VI<sup>MV</sup> was ≥7.15. With this definition, MV-Flow had the highest sensitivity (87.10%), with consistent findings for the combined diagnostic methods and O-RADS US (83.87%). The specificity of the combined diagnostic methods (93.83%) was higher than that of MV-Flow (91.36%). O-RADS US had the lowest specificity (90.12%). The combined diagnostic methods had the highest coincidence rate (91.07%), and MV-Flow (90.18%) had a significantly higher coincidence rate than O-RADS US (88.39%). Both O-RADS US and MV-Flow showed good consistency among different physicians (former kappa, 0.974; latter intraclass correlation coefficient [ICC], 0.986). MV-Flow had a high consistency for the same physician (ICC, 1).Conclusion: O-RADS US and MV-Flow exhibited good diagnostic efficacy, and their combined diagnostic efficacy was higher than that of each individually. O-RADS US and MV-Flow can improve the diagnosis of benign and malignant ovarian-adnexal masses. Purpose: This study aimed to explore the application of Ovarian-Adnexal Reporting and Data System Ultrasound (O-RADS US) combined with MV-Flow (Samsung Medison Co., Ltd.) to diagnose ovarian-adnexal masses. Methods: A total of 112 ovarian-adnexal masses (81 benign and 31 malignant) from 105 consecutive patients were analyzed. The O-RADS US and vascular index from MV-Flow (VIMV) were measured and compared with the reference standard. O-RADS US and MV-Flow were tested for consistency. Results: Receiver operating characteristic curves were drawn for O-RADS US, MV-Flow, and their combination. The combined methods had the largest area under the curve (0.955), followed by O-RADS US (0.929) and MV-Flow (0.923). A mass was considered malignant when the O-RADS US classification was 5 and VIMV was ≥7.15. With this definition, MV-Flow had the highest sensitivity (87.10%), with consistent findings for the combined diagnostic methods and O-RADS US (83.87%). The specificity of the combined diagnostic methods (93.83%) was higher than that of MV-Flow (91.36%). O-RADS US had the lowest specificity (90.12%). The combined diagnostic methods had the highest coincidence rate (91.07%), and MV-Flow (90.18%) had a significantly higher coincidence rate than O-RADS US (88.39%). Both O-RADS US and MV-Flow showed good consistency among different physicians (former kappa, 0.974; latter intraclass correlation coefficient [ICC], 0.986). MV-Flow had a high consistency for the same physician (ICC, 1). Conclusion: O-RADS US and MV-Flow exhibited good diagnostic efficacy, and their combined diagnostic efficacy was higher than that of each individually. O-RADS US and MV-Flow can improve the diagnosis of benign and malignant ovarian-adnexal masses.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼