RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Experimental Evaluation of Accelerated T1rho Relaxation Quantification in Human Liver Using Limited Spin-Lock Times

        Feng Zhao,Min Deng,Jing Yuan,Gao-Jun Teng,Anil T Ahuja,Yi-Xiang J. Wang 대한영상의학회 2012 Korean Journal of Radiology Vol.13 No.6

        Objective: It was reported lately that to obtain consistent liver T1rho measurement, at 3T MRI using six spin-lock times (SLTs), is feasible. In this study, the feasibility of using three or two SLT points to measure liver T1rho relaxation time was explored. Materials and Methods: Seventeen healthy volunteers underwent 36 examinations. Three representative axial slices were selected to cut through the upper, middle, and lower liver. A rotary echo spin-lock pulse was implemented in a 2D fast field echo sequence. Spin-lock frequency was 500 Hz and the spin-lock times of 1, 10, 20, 30, 40, and 50 milliseconds (ms) were used for T1rho mapping. T1rho maps were constructed by using all 6 SLT points, three SLT points of 1, 20, and 50 ms, or two SLTs of 1 and 50 ms, respectively. Intra-class correlation coefficient (ICC) and Bland and Altman plot were used to assess the measurement agreement. Results: Two examinations were excluded, due to motion artifact at the SLT of 50 ms. With the remaining 34 examinations, the ICC for 6-SLT vs. 3-SLT T1rho measurements was 0.922, while the ICC for 6-SLT vs. 2-SLT T1rho measurement was 0.756. The Bland and Altman analysis showed a mean difference of 0.19 (95% limits of agreement: -1.34, 1.73) for 6-SLT vs. 3-SLT T1rho measurement, and the mean difference of 0.89 (95% limits of agreement: -1.67, 3.45) for 6-SLT vs. 2-SLT T1rho measurement. The scan re-scan reproducibility ICC (n = 11 subjects) was 0.755, 0.727, and 0.528 for 6-SLT measurement, 3-SLT measurement, and 2-SLT measurement, respectively. Conclusion: Adopting 3 SLTs of 1, 20, and 50 ms can be an acceptable alternative for the liver T1rho measurement, while 2 SLTs of 1 and 50 ms do not provide reliable measurement. Objective: It was reported lately that to obtain consistent liver T1rho measurement, at 3T MRI using six spin-lock times (SLTs), is feasible. In this study, the feasibility of using three or two SLT points to measure liver T1rho relaxation time was explored. Materials and Methods: Seventeen healthy volunteers underwent 36 examinations. Three representative axial slices were selected to cut through the upper, middle, and lower liver. A rotary echo spin-lock pulse was implemented in a 2D fast field echo sequence. Spin-lock frequency was 500 Hz and the spin-lock times of 1, 10, 20, 30, 40, and 50 milliseconds (ms) were used for T1rho mapping. T1rho maps were constructed by using all 6 SLT points, three SLT points of 1, 20, and 50 ms, or two SLTs of 1 and 50 ms, respectively. Intra-class correlation coefficient (ICC) and Bland and Altman plot were used to assess the measurement agreement. Results: Two examinations were excluded, due to motion artifact at the SLT of 50 ms. With the remaining 34 examinations, the ICC for 6-SLT vs. 3-SLT T1rho measurements was 0.922, while the ICC for 6-SLT vs. 2-SLT T1rho measurement was 0.756. The Bland and Altman analysis showed a mean difference of 0.19 (95% limits of agreement: -1.34, 1.73) for 6-SLT vs. 3-SLT T1rho measurement, and the mean difference of 0.89 (95% limits of agreement: -1.67, 3.45) for 6-SLT vs. 2-SLT T1rho measurement. The scan re-scan reproducibility ICC (n = 11 subjects) was 0.755, 0.727, and 0.528 for 6-SLT measurement, 3-SLT measurement, and 2-SLT measurement, respectively. Conclusion: Adopting 3 SLTs of 1, 20, and 50 ms can be an acceptable alternative for the liver T1rho measurement, while 2 SLTs of 1 and 50 ms do not provide reliable measurement.

      • c-Cbl-Mediated Neddylation Antagonizes Ubiquitination and Degradation of the TGF-β Type II Receptor

        Zuo, W.,Huang, F.,Chiang, Y.,Li, M.,Du, J.,Ding, Y.,Zhang, T.,Lee, H.,Jeong, L.,Chen, Y.,Deng, H.,Feng, X.H.,Luo, S.,Gao, C.,Chen, Y.G. Cell Press 2013 Molecular cell Vol.49 No.3

        Transforming growth factor β (TGF-β) is a potent antiproliferative factor in multiple types of cells. Deregulation of TGF-β signaling is associated with the development of many cancers, including leukemia, though the molecular mechanisms are largely unclear. Here, we show that Casitas B-lineage lymphoma (c-Cbl), a known proto-oncogene encoding an ubiquitin E3 ligase, promotes TGF-β signaling by neddylating and stabilizing the type II receptor (TβRII). Knockout of c-Cbl decreases the TβRII protein level and desensitizes hematopoietic stem or progenitor cells to TGF-β stimulation, while c-Cbl overexpression stabilizes TβRII and sensitizes leukemia cells to TGF-β. c-Cbl conjugates neural precursor cell-expressed, developmentally downregulated 8 (NEDD8), a ubiquitin-like protein, to TβRII at Lys556 and Lys567. Neddylation of TβRII promotes its endocytosis to EEA1-positive early endosomes while preventing its endocytosis to caveolin-positive compartments, therefore inhibiting TβRII ubiquitination and degradation. We have also identified a neddylation-activity-defective c-Cbl mutation from leukemia patients, implying a link between aberrant TβRII neddylation and leukemia development.

      • Coronary Atherosclerosis T<sub>1</sub>-Weighed Characterization With Integrated Anatomical Reference

        Xie, Y.,Kim, Y.J.,Pang, J.,Kim, J.S.,Yang, Q.,Wei, J.,Nguyen, C.T.,Deng, Z.,Choi, B.W.,Fan, Z.,Bairey Merz, C.N.,Shah, P.K.,Berman, D.S.,Chang, H.J.,Li, D. Elsevier Science B.V. Amsterdam 2017 JACC CARDIOVASCULAR IMAGING Vol.10 No.6

        Objectives: The aim of this work is the development of coronary atherosclerosis T<SUB>1</SUB>-weighted characterization with integrated anatomical reference (CATCH) technique and the validation by comparison with high-risk plaque features (HRPF) observed on intracoronary optical coherence tomography (OCT) and invasive coronary angiography. Background: T<SUB>1</SUB>-weighted cardiac magnetic resonance with or without contrast media has been used for characterizing coronary atherosclerosis showing promising prognostic value. Several limitations include: 1) coverage is limited to proximal coronary segments; 2) spatial resolution is low and often anisotropic; and 3) a separate magnetic resonance angiography acquisition is needed to localize lesions. Methods: CATCH acquired dark-blood T<SUB>1</SUB>-weighted images and bright-blood anatomical reference images in an interleaved fashion. Retrospective motion correction with 100% respiratory gating efficiency was achieved. Reference control subjects (n = 13) completed both pre- and post-contrast scans. Stable angina patients (n = 30) completed pre-contrast scans, among whom 26 eligible patients also completed post-contrast scans. After cardiac magnetic resonance, eligible patients (n = 22) underwent invasive coronary angiography and OCT for the interrogation of coronary atherosclerosis. OCT images were assessed and scored for HRPF (lipid-richness, macrophages, cholesterol crystals, and microvessels) by 2 experienced analysts blinded to magnetic resonance results. Results: Per-subject analysis showed none of the 13 reference control subjects had coronary hyperintensive plaques (CHIP) in either pre-contrast or post-contrast CATCH. Five patients had CHIP on pre-contrast CATCH and 5 patients had CHIP on post-contrast CATCH. Patients with CHIP had greater lipid abnormality than those without. Per-segment analysis showed elevated pre- and post-contrast plaque to myocardium signal ratio in the lesions with HRPF versus those without. Positive correlation was observed between plaque to myocardium signal ratio and OCT HRPF scoring. CHIP on pre-contrast CATCH were associated with significantly higher stenosis level than non-CHIP on invasive coronary angiography. Conclusions: CATCH provided accelerated whole heart coronary plaque characterization with simultaneously acquired anatomical reference. CHIP detected by CATCH showed positive association with high-risk plaque features on invasive imaging studies.

      • SCOPUSKCI등재

        Growth hormone and receptor gene mutations in Chinese Banna miniature pig

        Deng, J.Z.,Hao, L.L.,Li, M.T.,Lang, S.,Zeng, Y.Z.,Liu, S.C.,Zhang, Y.L. The Korean Society for Integrative Biology 2011 Animal cells and systems Vol.15 No.4

        The Banna miniature pig (BNMP) is a representative miniature pig breed in China. Even though BNMP dwarfism is obvious, its underlying causative mutations remain unknown. In this study, the BNMP and Large White pig (LWP) serum growth hormone (GH) and insulin-like growth factor (IGF-1) levels were detected by ELISA and compared. BNMP serum IGF-1 levels were significantly lower than LWP levels (P<0.05). The miniature condition may arise from mutations in the GH and GH receptor (GHR) genes. Therefore, GH and GHR cDNA from the BNMP were cloned into a pMD18-T vector by RT-PCR using the total RNA obtained from the BNMP's pituitary and liver tissues. Sequencing results indicated that the open reading frame of the BNMP GH gene is composed of a 26-residue signal peptide and a 191-residue mature peptide. The coding sequence of the BNMP GHR gene contained 639 amino acids, including a signal peptide that is 18 amino acids long. Two amino acid substitutions, A09V and R22Q, were found in the signal peptide of the GH gene. Additionally, the S104P mutation was found in the BNMP's mature GH protein. Four mutations in the cytoplasmic domain of GHR may influence the downstream signal transduction of GHR, which needs further experimental evidence.

      • KCI등재

        Growth hormone and receptor gene mutations in Chinese Banna miniature pig

        J.Z. Deng,L.L. Hao,M.T. Li,S. Lang,Y.Z. Zeng,S.C. Liu,Y.L. Zhang 한국통합생물학회 2011 Animal cells and systems Vol.15 No.4

        The Banna miniature pig (BNMP) is a representative miniature pig breed in China. Even though BNMP dwarfism is obvious, its underlying causative mutations remain unknown. In this study, the BNMP and Large White pig (LWP)serum growth hormone (GH) and insulin-like growth factor (IGF-1) levels were detected by ELISA and compared. BNMP serum IGF-1 levels were significantly lower than LWP levels (P<0.05). The miniature condition may arise from mutations in the GH and GH receptor (GHR) genes. Therefore, GH and GHR cDNA from the BNMP were cloned into a pMD18-T vector by RT-PCR using the total RNA obtained from the BNMP’s pituitary and liver tissues. Sequencing results indicated that the open reading frame of the BNMP GH gene is composed of a 26-residue signal peptide and a 191-residue mature peptide. The coding sequence of the BNMP GHR gene contained 639 amino acids, including a signal peptide that is 18 amino acids long. Two amino acid substitutions, A09V and R22Q, were found in the signal peptide of the GH gene. Additionally, the S104P mutation was found in the BNMP’s mature GH protein. Four mutations in the cytoplasmic domain of GHR may influence the downstream signal transduction of GHR, which needs further experimental evidence.

      • KCI등재

        대기중의 휘발성 유기물 제거용 분리막

        Deng S.,Lang K.,Wang J.,Tremblay A.,Matsuura T. 한국막학회 1997 멤브레인 Vol.7 No.1

        Porous asymmetric membranes were prepared from polyetherimide polymer by the phase-inversion technique under different conditions. The performance of the membranes was tested for the removal of acetone vapour from nitrogen. A membrane which showed a high acetone permeability and a high selectivity was chosen and tested further for the separation of different organic vapours from nitrogen. The molecular structure of organic vapours and the selectivity were correlated. A strong correlation was also found between the chromatographic retention time of the organic vapour and the selectivity. These experimental results led to the conclusion that the sorption is the factor governing the separation of volatile organic compounds from nitrogen. A membrane was also prepared by coating the surface of a porous polyetherimide membrane with silicone rubber. The performance of membranes with and without silicone rubber coating was compared.

      • The properties of dry-spun carbon nanotube fibers and their interfacial shear strength in an epoxy composite

        Deng, F.,Lu, W.,Zhao, H.,Zhu, Y.,Kim, B.S.,Chou, T.W. Pergamon Press ; Elsevier Science Ltd 2011 Carbon Vol.49 No.5

        Continuous fibers composed of carbon nanotubes have been adopted as reinforcements for polymeric composites. This paper presents several fundamental studies relevant to the mechanical behavior of CNT fibers, including fiber tensile behavior; in situ SEM observation of fiber deformation mechanisms; and fiber modulus, ultimate strength and fracture strain measurements. A modified Weibull strength distribution model that takes into account the flaw density variation with fiber diameter has been adopted for the statistical strength analysis. The interfacial shear strength between the carbon nanotube fiber and the epoxy matrix has been measured using fragmentation tests of single-fiber composites.

      • KCI등재

        Membrane for the Removal of Volatile Organic Compounds from Air

        Deng, S.,Lang, K.,Wang, J.,Tremblay, A.,Matsuura, T. The Membrane Society of Korea 1997 멤브레인 Vol.7 No.1

        Porous asymmetric membranes were prepared from polyetherimide polymer by the phase-inversion technique under different conditions. The performance of the membranes was tested for the removal of acetone vapour from nitrogen. A membrane which showed a high acetone permeability and a high selectivity was chosen and tested further for the separation of different organic vapours from nitrogen. The molecular structure of organic vapours and the selectivity were correlated. A strong correlation was also found between the chromatographic retention time of the organic vapour and the selectivity. These experimental results led to the conclusion that the sorption is the factor governing the separation of volatile organic compounds from nitrogen. A membrane was also prepared by coating the surface of a porous polyetherimide membrane with silicone rubber. The performance of membranes with and without silicone rubber coating was compared.

      • KCI등재

        Effect of the Ratio of Non-fibrous Carbohydrates to Neutral Detergent Fiber and Protein Structure on Intake, Digestibility, Rumen Fermentation, and Nitrogen Metabolism in Lambs

        T. Ma,Y. Tu,N.F. Zhang,K.D. Deng,Q.Y. Diao 아세아·태평양축산학회 2015 Animal Bioscience Vol.28 No.10

        This study aimed to investigate the effect of the ratio of non-fibrous carbohydrates to neutral detergent fibre (NFC/NDF) and undegraded dietary protein (UDP) on rumen fermentation and nitrogen metabolism in lambs. Four Dorper×thin-tailed Han crossbred lambs, averaging 62.3±1.9 kg of body weight and 10 mo of age, were randomly assigned to four dietary treatments of combinations of two levels of NFC/NDF (1.0 and 1.7) and two levels of UDP (35% and 50% of crude protein [CP]). Duodenal nutrient flows were measured with dual markers of Yb and Co, and microbial N (MN) synthesis was estimated using 15N. High UDP decreased organic matter (OM) intake (p = 0.002) and CP intake (p = 0.005). Ruminal pH (p<0.001), ammonia nitrogen (NH3-N; p = 0.008), and total volatile fatty acids (p<0.001) were affected by dietary NFC/NDF. The ruminal concentration of NH3-N was also affected by UDP (p<0.001). The duodenal flow of total MN (p = 0.007) was greater for lambs fed the high NFC/NDF diet. The amount of metabolisable N increased with increasing dietary NFC:NDF (p = 0.02) or UDP (p = 0.04). In conclusion, the diets with high NFC/NDF (1.7) and UDP (50% of CP) improved metabolisable N supply to lambs.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼