RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • 고성토 제방의 부지응답해석을 위한 전단강성 평가

        조성호(Sung-Ho Joh),노리나(Norinah Abd Rahman),하사눌(Raja Hassanul) 한국철도학회 2010 한국철도학회 학술발표대회논문집 Vol.2010 No.7

        High rock-fill embankment is relatively flexible, which makes crest of embankment subject to excessive amplification in displacement due to earthquake loading. To overcome problems related with site response in high embankment, it is essential to evaluate shear-wave velocity profile of the embankment with improved accuracy and reliability. In this aspect, an experimental research was performed to answer how to perform surface-wave tests and to analyze measurements at an embankment site with a sloping ground surface. Unlike flat ground surface, sloping ground may hamper and slow down propagation of surface waves due to multiple reflections and refractions in embankment. To figure out this reasoning for the effect of multiple reflections and refractions due to sloping surface, surface wave tests were performed at a reservoir embankment of Chung-Song in North KyeongSang Province. Parameters involved in surface wave tests at non-flat surface, including source directionality, geometry-related constraint and frequency components in source function, were investigated using field measurements.

      • KCI등재

        다중필터링에 의한 PDC-R 기법의 자동화 해석

        조성호(Joh Sung-Ho),노리나(Rahman Norinah Abd),하사눌(Hassanul Raja) 대한토목학회 2010 대한토목학회논문집 C Vol.30 No.3

        지반내 존재하는 자연전위, 돌발성 전기잡음, 60㎐ 전기잡음 등은 전기비저항 시험에 있어서 신뢰성을 저하하는 요인 중의 하나이다. 특히 최근 개발된 저주파 교류를 사용하는 PDC-R(Pseudo DC Resistivity) 시험의 자료해석에 있어서도 해석의 신뢰성을 저하시키는 요인이 되고 있다. 즉 직류기반 전기비저항 시험, 교류기반 전기비저항 시험 모두에 있어서 정도의 차이가 있을 뿐 전기잡음은 전기비저항 기법의 신뢰도에 여전히 영향을 주고 있다. 본 연구에서는 PDC-R 기법의 자료해석에 있어서 전기잡음의 영향을 최소화하여 기법의 신뢰성을 제고할 수 있는 방안을 제시하였다. 또한 이를 구현하는 자동화 알고리듬을 이용하여 PDC-R 기법의 적용성도 개선하도록 하였다. 본 연구에서 제안하는 PDC-R 시험데이터의 자동화 해석 기법은 두 단계로 구성되어 있는데, 그 첫 번째는 다중필터링을 시용하여 입력전류와 동일한 주파수 성분을 추출하는 것이고, 두 번째 단계는 추출된 자료 중에서 안정적 거동의 신호성분만 분류해 내는 작업을 수행하는 것이다. 이러한 자동화 기법은 자연전위, 돌발성 잡음, 60㎐ 전기잡음 등을 포함한 가상의 조화함수를 이용하여 그 정확성과 안정성을 확인하였다. 또한 현장적용을 통하여 제안된 기법의 적용성 및 정확성도 확인할 수 있었다. Electrical noises like self potential, burst noises and 60-㎐ electrical noises are one of the causes to reduce reliability of electrical resistivity survey. Even the PDC-R (Pseudo DC resisitivity) technique, recently developed, is suffering from the problem of low reliability due to electrical noises. That is, both DC-based and AC-based resistivity technique is subject to reliability problem due to electrical noises embedded in urban geotechnical sites. In this research, a new technique to enhance reliability of the PDC-R technique by minimizing influence of electrical noises was proposed. In addition, an automated procedure was also proposed to facilitate data analysis and interpretation of PDC-R measurements. The proposed technique is composed of two steps: 1. to extract information only related with the input current by means of multiple-filter technique, and 2. to undertake a task to sort out signal information only to show stable and reliable characteristics. This automated procedure was verified by a synthetic harmonic wave including DC shift, burst random noises and 60-Hz electrical noises. Also the procedure was applied to site investigation at urban areas for proving its feasibility and accuracy.

      • SCOPUSKCI등재
      • KCI등재

        표면파 기법에 의한 콘크리트 사방댐의 콘크리트 강도 등급 평가

        이창우 ( Chang Woo Lee ),조성호 ( Sung Ho Joh ),박기형 ( Ki Hyung Park ),김민식 ( Min Sik Kim ),윤호중 ( Ho Joong Yoon ),하사눌 ( Raja Hassanul ) 한국임학회 2012 한국산림과학회지 Vol.101 No.3

        산지계곡부의 토석류 유출을 저지하는 콘크리트 사방댐은 콘크리트의 재료 및 시공 불량, 콘크리트의 열화로 인한 내구성 저하, 국부적으로 발생한 균열 등의 이유로 인하여 사방댐의 일부 또는 전체 구조물이 붕괴되어 그 기능을 손실하는 경우가 있다. 본 논문에서는 이러한 콘크리트 사방댐의 구조적 문제점과 안전성을 파악하여 사전 에 대책을 강구하고 효율적인 유지관리를 할 수 있는 방안을 제안하였다. 그 방안은 콘크리트 사방댐 구조물의 콘 크리트 압축강도를 비파괴적으로 평가하여 품질등급을 평가하는 것으로, 등급평가 단계에서 비파괴 콘크리트 압축강 도 평가를 위해 SASW 기법이라고 하는 표면파 기법을 도입하였다. 또한 SASW 기법을 콘크리트 사방댐의 안정성 평가에 활용할 수 있도록 SASW 시험의 현장적용방안, 콘크리트 결함에 따른 자료분석 기법, 평가기준에 대한 제안 등에 대한 연구를 수행하였다. 제안된 기법의 적용성과 신뢰성을 평가하기 위하여, 20년 이상 경과된 노후 콘크리트 사방댐 5곳에 제안된 표면파 기법의 적용방안을 적용하여 보았다. 그 결과 콘크리트 사방댐의 여러 가지 콘크리트 결함에 대해서도 SASW 기법에 의한 품질평가는 신뢰성 있게 수행될 수 있음을 확인할 수 있었고, 본 연구에서 제 안한 품질등급 평가 결과는 사방협회에서 실시한 사방댐 점검결과와 일치하는 결과를 제시하였다. Concrete Soil Erosion Control Dam, which blocks flow of debris flow in torrential stream, are reported to lose expected functions due to structural failure and collapses, caused by poor construction, material deterioration and external impacts, In this paper, an integrity assessment technique for debris barriers was proposed, which allows preliminary detection of problems inherent in debris barriers. The proposed integrity assessment technique is a non-destructive method based on SASW method, one of surface-wave tests. In this paper, a practical procedure and analysis guidelines in applying the SASW technique to debris barrier was proposed and its validity was verified using five decrepit debris barriers older than 20-year old. As a result, the SASW method was validated for the reliable grade evaluation method for concrete soil erosion control dam, and the resulting grades turned out to agree with the results determined by Sabang Associations.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼