http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
족삼리(足三里)와 위유(胃兪)의 경혈배합(經穴配合)과 병용자극(竝用刺戟)이 정상(正常) 백서(白鼠) 위기능(胃機能)에 미치는 영향(影響)
윤민영,김경식,황우준,이건목,이옥자,김홍훈,윤정안,유윤조,박종운,조남근,Yun, Min-young,Kim, Kyung-sik,Hwang, Woo-jun,Lee, Geon-mok,Lee, Ok-ja,Kim, Hong-hoon,Yun, Jung-an,Yu, Yun-cho,Park, Jong-un,Cho, Nam-geun 대한침구의학회 2004 대한침구의학회지 Vol.21 No.5
It is well known that both of acupuncture and moxibustion are effective for treatment of human disease. For years, they have been utilizing a electro-acupuncture (EA) and moxibustion in attempt to manage gastric symptom. However, the data of combined EA and moxibustion on clinical effectiveness is conflicting and the action of combineAd acupoints is not well known. BL21 and ST36 which belong to bladder Meridian and stomach meridian are acupuncture points frequently used for healing gastrointestinal disease in oriental medicine. The present study was conducted to see the effects produced by combined electro-acupuncture(EA) and moxibustion using BL21 and ST36 on serum gastrin level in rats. In experiment, male Spraque-Dawley rats(body wt 140-160g) were selected. EA (2 Hz, intensity ; 10 times muscle twitch threshold) was applied for 30 minutes to ST36 under halothane anesthesia. Moxibustion($1.6{\pm}0.3 mg$, 5 times of a day) was applied during 3 days to BL21 under halothane anesthesia. Synergy effects of combined EA and moxibustion might be in according to stimulated method and used acupoints. The change of serum gastrin levels produced by combined EA and moxibustion is shown after vagotomy. These data suggested that many factors, such as the selection of acupoints, the stimulated EA methods, are capable of affecting combined EA and moxibustion effects and those effects may be not related with nervous system.
윤민영,박경수,왕국명,김선재,길경석,Yun, Min-Young,Park, Kyoung-Soo,Wang, Guoming,Kim, Sun-Jae,Kil, Gyung-Suk 한국전기전자재료학회 2016 전기전자재료학회논문지 Vol.29 No.2
This paper dealt with the propagation characteristics of acoustic signal in insulation oil for the purpose of improving the reliability of AE (acoustic emission) method used for condition monitoring of oil-immersed transformers. A discharge source was placed in insulation oil and AE sensors ($f_c$ :140 kHz) were attached on the oil tank to study the changes of velocity and propagation path with the depth and distance. The average velocity was 1,436 m/s and the velocity decreased with the increase of depth from the oil surface to 430 mm. The propagation paths were classified into three sections by the shortest reflection path of the detected signal. The minimum distinguishable distance in each section was 70 mm. It was also verified that PD (partial discharge) with a magnitude over than 500 pC can be detected by the AE sensors.