http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
안민희,최창호,Ahn, Min-Hee,Choi, Chang-Ho 한국태양에너지학회 2007 한국태양에너지학회 논문집 Vol.27 No.3
This paper addresses the indoor air quality when radiant floor heating is applied in large space. Radiant heat exchange between surfaces depends on the orientation and the temperature of the surfaces. Also, the temperature and the radiant characteristic of the wall and the roof that face the floor have great influence on the indoor air environment due to the largeness of the wall and the roof in large spaces. In this study, we simulate a test-cell(25X20X10) using a ies YE And using a CFD(microflo in VE), an indoor air environment was investigated to establish the optimum temperature of floor. At the first time of the heating, high floor temperature is demanded. At the middle of the heating, however, the temperature of the residential space was formed appropriately, although the temperature of the floor was set low.
안민희(Minhee Ahn),양세양(Seiyang Yang),윤재근(Jaegeun Yun) 한국정보과학회 2003 정보과학회 컴퓨팅의 실제 논문지 Vol.9 No.5
최근까지 초고집적 FPGA 혹은 재구성가능 프로세서 들을 이용한 RC(재구성 컴퓨팅) 기술에 대한 많은 연구가 진행되어 왔으며, 최근 들어서는 이와 같은 RC 기술을 응용분야에 실제 적용한 성공적인 상용화 사례들이 보고되고 있다. 본 논문에서는 FPGA의 동적 재구성 기능과 RC 기법을 이용하여 DES 암호화 시스템을 적은 용량의 FPGA에 구현하기 위한 설계와 구현된 DES 암호화 시스템의 시스템 수준 검증 기법을 제안한다. 이를 통하여 동적 재구성 기반의 접근법이 가지는 유용성을 평가할 수 있었는데, 그것은 FPGA의 동적 재구성성을 통하여 임의의 알고리즘의 RC 기법에 의한 하드웨어 구현에 있어서 성능과 가격간의 타협이 매우 효과적으로 이루어 질 수 있다는 것이다. Recently, many researches on RC(Reconfigurable Computing) with highly complex FPGA’s and reconfigurable processors have been reported, and even some attempts for commercialization have been successful. In this paper, we introduce the design methodology for implementing DES crypto algorithm on small-capacity FPGA by using its dynamic reconfigurability and a system-level verification technique. Throughout this design project, we could evaluate the effectiveness of this approach, which is the dynamic reconfigurability of FPGAs makes the efficient trade-off between the performance and the cost robustly viable.
뇌파기반 항스트레스 지수에 의한 직장인의 스트레스 반영도 분석
안민희(Ahn, Min-Hee) 한국산학기술학회 2010 한국산학기술학회논문지 Vol.11 No.10
뇌파는 시시각각 변하는 뇌 상태를 가장 효과적으로 측정하는 수단이다. 뇌는 신진대사의 근간인 호르몬과 직접적인 관계가 있으므로 뇌파와 호르몬간의 영향관계를 규명할 필요가 있다. 본 연구는 뇌파만으로 신진대사와 관 련된 정보의 산출이 가능함을 밝히는 연구를 수행하였다. 주요 연구변수는, 2007년 3월 3일부터 5월 28일까지 측정한, 직장인 여성들의 스트레스 정보인 뇌파 항스트레스 지수와 코티졸 호르몬 농도이다. 이들 간의 영향관계를 밝히고자, 뇌파훈련 전후에 대한 t검증, 상관분석, 회귀분석을 주된 연구방법으로 수행하였으며, 다음과 같은 결과가 도출되었다. 첫째, 뇌파훈련에 의해 변수들의 변화에 대한 유의한 차이가 검증되었다. 둘째, 변수들 간에 상관성이 존재함을 규명 하였다. 마지막으로 회귀분석에서, 변수들 간에 영향력이 있는 것으로 파악되었다. 그러므로 뇌파분석만으로도 호르몬 분석수준의 스트레스 정보를 제공할 수 있다는 결론에 도달하였다. Brainwave can be the most effective means of detecting the state of the brain that changes moment by moment. Since brain has closed relations with hormones which are a foundation of metabolism, it needs to examine closely the mutual relationship between brainwave and hormone. We examined the possibility to find out such information about metabolism by comparing brainwave with cortisol hormone. The major variables are anti-stress quotient of brainwave and cortisol density which give stress information of the working women, to measure from March 3 to May 28, 2007. To find out the relationship between them, we performed such statistical analysis about the before and after of brainwave training as t-test, correlational analysis and regression analysis. We obtained following results: First, considerable changes of variables is shown by brain-wave training. Second, there exist a correlation between variables. Third, according to regression analysis, influence between variables is verified. Thus, we found that stress information of hormone analytical level can be obtined only through brainwave analysis.
안민희(Ahn Min-Hee),최창호(Choi Chang-Ho),이현우(Lee Hyeon-Woo),조민관(Cho Min-Kwan) 한국태양에너지학회 2006 한국태양에너지학회 논문집 Vol.26 No.1
This paper presents an analysis of heating energy for apartment houses in apartment building, paying special attention on the effect of pilotis which is increasing recently. A four-zone model composed of one conditioned and three unconditioned space is developed in this study. IES VE is adopted to estimate heating energy. Especially, we used Apache module for a heating energy calculated. The predicted result shows fairly good agreements with the available measured data and simulation data. Heating energy needed for an apartment located on the pilotis floors is far greater compared with the case of intermediate floors. Insulation thickness of walls, floors and underground structure appears to be a dominant factor affecting heating energy, which leads to needs of revision of the related regulation. It is finally concluded that the location dependent, severe imbalance in heating energy should be improved and reflected in the policy making process and the design standards.