        Voltage Distortion Suppression for Off-grid Inverters with an Improved Load Current Feedforward Control

        Geng, Yiwen,Zhang, Xue,Li, Xiaoqiang,Wang, Kai,Yuan, Xibo The Korean Institute of Power Electronics 2017 JOURNAL OF POWER ELECTRONICS Vol.17 No.3

        The output voltage of an off-grid inverter is influenced by load current, and the voltage harmonics especially the 5th and 7th are increased with nonlinear loads. In this paper, to attenuate the output voltage harmonics of off-grid inverters with nonlinear loads nearby, a load current feedforward is proposed. It is introduced to a voltage control loop based on the Positive and Negative Sequence Harmonic Regulator (PNSHR) compensation to modify the output impedance at selective frequencies. The parameters of the PNSHR are revised with the output impedance of the off-grid inverter, which minimizes the output impedance of the off-grid inverter. Experimental results verify the proposed method, showing that the output voltage harmonics caused by nonlinear loads can be effectively suppressed.

      • SCIESCOPUSKCI등재

        A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters

        Geng, Yiwen,Qi, Yawen,Zheng, Pengfei,Guo, Fei,Gao, Xiang The Korean Institute of Power Electronics 2018 JOURNAL OF POWER ELECTRONICS Vol.18 No.5

        Proportional capacitor-current-feedback active damping (AD) is a common damping method for the resonance of LCL-type grid-connected inverters. Proportional capacitor-current-feedback AD behaves as a virtual resistor in parallel with the capacitor. However, the existence of delay in the actual control system causes impedance in the virtual resistor. Impedance is manifested as negative resistance when the resonance frequency exceeds one-sixth of the sampling frequency ($f_s/6$). As a result, the damping effect disappears. To extend the system damping region, this study proposes a virtual resistor-inductor-capacitor (RLC) AD method. The method is implemented by feeding the filter capacitor current passing through a band-pass filter, which functions as a virtual RLC in parallel with the filter capacitor to achieve positive resistance in a wide resonance frequency range. A combination of Nyquist theory and system close-loop pole-zero diagrams is used for damping parameter design to obtain optimal damping parameters. An experiment is performed with a 10 kW grid-connected inverter. The effectiveness of the proposed AD method and the system's robustness against grid impedance variation are demonstrated.

      • KCI등재

        A Virtual RLC Active Damping Method for LCL-Type Grid-Connected Inverters

        Yiwen Geng,Yawen Qi,Pengfei Zheng,Fei Guo,Xiang Gao 전력전자학회 2018 JOURNAL OF POWER ELECTRONICS Vol.18 No.5

        Proportional capacitor–current–feedback active damping (AD) is a common damping method for the resonance of LCL-type grid-connected inverters. Proportional capacitor–current–feedback AD behaves as a virtual resistor in parallel with the capacitor. However, the existence of delay in the actual control system causes impedance in the virtual resistor. Impedance is manifested as negative resistance when the resonance frequency exceeds one-sixth of the sampling frequency (fs/6). As a result, the damping effect disappears. To extend the system damping region, this study proposes a virtual resistor–inductor–capacitor (RLC) AD method. The method is implemented by feeding the filter capacitor current passing through a band-pass filter, which functions as a virtual RLC in parallel with the filter capacitor to achieve positive resistance in a wide resonance frequency range. A combination of Nyquist theory and system close-loop pole-zero diagrams is used for damping parameter design to obtain optimal damping parameters. An experiment is performed with a 10 kW grid-connected inverter. The effectiveness of the proposed AD method and the system’s robustness against grid impedance variation are demonstrated.