RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        Splenic T1-Mapping for Predicting Adenosine Stress Adequacy in Cardiac Magnetic Resonance Myocardial Perfusion Imaging: A Validation and Reproducibility Study

        Wan Fiona Fong-ying,Yeung Catherine Ming-mun,Yam Pak-ki,Ng Pan Pan,Chow Boris Chun Kei,Chiang Jeanie Betsy,Lee Jonan Chun-yin,Cheung Kenneth Kai-yat,Ng Ming-yen 아시아심장혈관영상의학회 2022 Cardiovascular Imaging Asia Vol.6 No.3

        Objective:Splenic switch-off (SSO) sign has been utilized as a surrogate marker of adequate stress but can only be assessed after first-pass perfusion imaging. A study previously reported that drop in T1spleen ≥30 ms during adenosine infusion predicts presence of SSO, but this finding has not been externally validated. This study aimed to prospectively validate whether drop in T1spleen ≥30 ms is a reliable marker of SSO and hence adequate stress, and to assess reproducibility of T1spleen measurements. Materials and Methods: Data of fifty consecutive patients undergoing stress cardiac magnetic resonance were prospectively collected. Native T1-maps were acquired at rest and at 2.5 min after adenosine infusion in short axis slices, followed by perfusion images at 3 min. To measure T1spleen pre- and post-adenosine infusion, regions of interest were manually placed to include most splenic tissue. Adenosine stress adequacy was evaluated by visual SSO assessment and semi-quantitative splenic perfusion analysis. Results:A significant association was found between a drop in T1spleen of ≥30 ms and SSO response (p<0.001). There was excellent correlation between SSO response and semiquantitative perfusion change in spleen (rho=0.847, p<0.001). Inter-observer and intra-observer agreement for measurement of ΔT1spleen values were excellent, with intra-class correlation coefficients of 0.987 and 0.995, respectively. By receiver-operating characteristic analysis, the optimal cut-off value of ΔT1spleen for predicting presence of SSO was -28 ms, with area under the curve=0.76 (p=0.002). Conclusion:Splenic T1-mapping is accurate and reproducible for predicting SSO, potentially allowing optimization of adenosine dosage for adequate stress.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼