RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재후보

        Evaluation of accuracy of different elastomeric materials in open tray implant level technique for single tooth impressions

        Sekar Abinaya,Mariappan Saravanakumar,Krishnan Chitra Shankar,Sampathkumar Jayakrishnakumar,Ramakrishnan Hariharan,Mahadevan Vallabh,Sivaprakasam Azhagarasan Nagarasampatti 대한치과이식(임프란트)학회 2022 The Korean Academy of Implant Dentistry Vol.41 No.4

        Purpose: This study compared the accuracy of different elastomeric impression materials with open tray implant level impression technique in a single-tooth replacement. Materials and Methods: A reference model representing a single implant with an adjacent simulated natural tooth was fabricated. Open tray implant level impressions were made with vinylpolysiloxane (light body ExpressXT, PentaputtyPentamix2, 3MESPE, Seinfield, Germany) (Group I, n=10) and polyether (medium body Impregnum Penta, Pentamix 2, 3MESPE, Seinfield, Germany), (Group II, n=10) and implant crowns were fabricated on each master cast from their respective impressions by CNC milling and connected to the reference model with 35 Ncm torque. The accuracy of the fit was evaluated by measuring the interface gap between the implant crown and the implant replica at the mesial and distal points and by measuring the proximal gap between the implant crown and the simulated natural tooth at the buccal and the palatal points by scanning electron microscopy for each test sample. The mean values were obtained and statistically analyzed using a Mann-Whitney test. Results: The interface gap observed at the mesial point was significantly higher than the distal point. The proximal gap observed at the palatal point was significantly higher than the buccal point for both Group I and Group II. A comparison of the groups showed that the interface gap at the mesial point and the proximal gap at the buccal and palatal points obtained from polyether impression material were lower than those observed with vinylpolysiloxane group, but the difference was not significant. However, the interface gap observed at the distal point was higher with the polyether group than with the vinylpolysiloxane group, but the difference was not significant. Conclusions: Polyether and vinylpolysiloxane can be used to produce open tray implant impressions for a single missing tooth.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼