RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        Assessing Reliability and Validity of an Instrument for Measuring Resilience Safety Culture in Sociotechnical Systems

        Shirali, Gholamabbas,Shekari, Mohammad,Angali, Kambiz Ahmadi Occupational Safety and Health Research Institute 2018 Safety and health at work Vol.9 No.3

        Background: Safety culture, acting as the oil necessary in an efficient safety management system, has its own weaknesses in the current conceptualization and utilization in practice. As a new approach, resilience safety culture (RSC) has been proposed to reduce these weaknesses and improve safety culture; however, it requires a valid and reliable instrument to be measured. This study aimed at evaluating the reliability and validity of such an instrument in measuring the RSC in sociotechnical systems. Methods: The researchers designed an instrument based on resilience engineering principles and safety culture as the first instrument to measure the RSC. The RSC instrument was distributed among 354 staff members from 12 units of an anonymous petrochemical plant through hand delivery. Content validity, confirmatory, and exploratory factor analysis were used to examine the construct validity, and Cronbach alpha and test-retest were employed to examine the reliability of the instrument. Results: The results of the content validity index and content validity ratio were calculated as 0.97 and 0.83, respectively. The explanatory factor analysis showed 14 factors with 68.29% total variance and 0.88 Kaiser-Meyer-Olkin index. The results were also confirmed with confirmatory factor analysis (relative Chi-square = 2453.49, Root Mean Square Error of Approximation = 0.04). The reliability of the RSC instrument, as measured by internal consistency, was found to be satisfactory (Cronbach ${\alpha}=0.94$). The results of test-retest reliability was r = 0.85, p < 0.001. Conclusion: The results of the study suggest that the measure shows acceptable validity and reliability.

      • KCI등재

        Assessing Reliability and Validity of an Instrument for Measuring Resilience Safety Culture in Sociotechnical Systems

        Gholamabbas Shirali,Mohammad Shekari,Kambiz Ahmadi Angali 한국산업안전보건공단 산업안전보건연구원 2018 Safety and health at work Vol.9 No.3

        Background: Safety culture, acting as the oil necessary in an efficient safety management system, has its own weaknesses in the current conceptualization and utilization in practice. As a new approach, resilience safety culture (RSC) has been proposed to reduce these weaknesses and improve safety culture; however, it requires a valid and reliable instrument to be measured. This study aimed at evaluating the reliability and validity of such an instrument in measuring the RSC in sociotechnical systems. Methods: The researchers designed an instrument based on resilience engineering principles and safety culture as the first instrument to measure the RSC. The RSC instrument was distributed among 354 staff members from 12 units of an anonymous petrochemical plant through hand delivery. Content validity, confirmatory, and exploratory factor analysis were used to examine the construct validity, and Cronbach alpha and test-retest were employed to examine the reliability of the instrument. Results: The results of the content validity index and content validity ratio were calculated as 0.97 and 0.83, respectively. The explanatory factor analysis showed 14 factors with 68.29% total variance and 0.88 Kaiser-Meyer-Olkin index. The results were also confirmed with confirmatory factor analysis (relative Chi-square = 2453.49, Root Mean Square Error of Approximation = 0.04). The reliability of the RSC instrument, as measured by internal consistency, was found to be satisfactory (Cronbach a = 0.94). The results of test-retest reliability was r ¼ 0.85, p < 0.001. Conclusion: The results of the study suggest that the measure shows acceptable validity and reliability.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼