APR1400 원자로냉각재계통 스너버의 비구속기능 상실의 영향 평가
황병천(Byung Chun Hwang),이한걸(Han Gul Lee),전장환(Jang Hwan Jheon),성기광(Ki Kwang Sung),김현민(Hyun Min Kim) 대한기계학회 2016 대한기계학회 춘추학술대회 Vol.2016 No.12
This study assesses the effects of a failure of snubber installed on two Steam Generators(SGs) and four Reactor Coolant Pumps(RCPs) in the APR1400 Reactor Coolant System(RCS) under normal operation(NOP) conditions. The analysis results show that the single snubber failure i.e., lockup, during the normal operation conditions has somewhat severe effects especially on the inlet nozzle of the SG and the outlet nozzle of the RCP. However, the resultant load increases on the RCS will be limited to a certain level since the failed snubber does not act as a restraint any more beyond the snubber load rate, and a stress evaluation reveals that the resultant stress intensities remain below the allowable. Additionally, the analysis results also show that the single snubber failure effects are confined to the component having the failed snubber. Accordingly, the single snubber failure in the RCS will not degrade the structural integrity of the RCS.