RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        해양과학기지에서 수행한 염분 표류 방지 실험 결과 및 염분 고품질 시계열 자료 생산을 위한 제언

        이재익(Jaeik Lee),이수찬(Suchan Lee),정종민(Jongmin Jeong),민용침(Yongchim Min),정진용(Jin-Yong Jeong),김용선(Yong Sun Kim) 한국연안방재학회 2021 한국연안방재학회지 Vol.8 No.4

        The importance of salinity has been highlighted to cope with climate changes and disaster prevention. The salinity of accuracy up to 0.005 is normally required in an open ocean to understand various oceanic and climatic phenomena; however, the reliability of salinity measured on the coast and open seas around Korea was low due to the lack of a standardized observation system and post-processing of quality verification. Korea Ocean Research Stations (KORS) has been producing salinity time series since 2003 through the Aanderaa conductivity-temperature (CT) 3919 inductive sensors, which have an advantage of on-site maintenance but tend to drift toward a lower conductivity because of biological attachments to the sensor. This study applied copper taping and UV light exposure techniques to the sensors and then compared its salinity measurements with RBR CTD mooring observations and SeaBird19 CTD profiles to assess a biofouling effect on salinity observations. This experiment shows that the salinity from the CT sensor without biofouling prevention starts to drift in a week, particularly for a surface sensor. This biofouling induced the decrease of salinity up to 10 in a month. The copper taping methodology efficiently suppressed the biological attachment but disturbed an electromagnetic field around the sensor, thus resulting in unrealistic salinity values. When UV light was periodically exposed at a distance of about 5 cm away from the CT sensor, relatively stable salinity could be observed without significant drift at least in two months. Besides, the SBE37 CTD, an electrode-type sensor, seems to be relatively free from biofouling but has difficulties in sensor maintenance and a sensor calibration process. Our results underline a double installation of salinity observation equipment with UV light exposure. In addition, the pre-calibration of a CT(D) sensor and post-verification should be included in a standard procedure for high-quality salinity measurement.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼