냉매 충진량과 모세관 길이변화에 따른 R410A 적용 가정용 에어컨 성능의 실험적 고찰
조진표(J. P. Cho),오왕규(W. K. Oh),김내현(N. H. Kim),김영수(Y. S. Kim),구명수(M. S. Koo),윤긍식(K. S. Yun),최영훈(Y. H. Choi) 대한기계학회 2001 대한기계학회 춘추학술대회 Vol.2001 No.9
In this study, we evaluated the performance of residential split type air-conditioner using alternative refrigerant R410A. Tested were variations of charging conditions and capillary tubes length. The objective of this study was to quantify the influence of the refrigerant charge and capillary tubes under the steady state operation of a split type air-conditioning system. as the refrigerant charge is increased, both the evaporating and condensing temperature increase gradually, and the cooling capacity, EER, power consumption has optimum refrigerant charge. In case of inner diameter 1.6㎜, length 1000㎜ that a 10% under charge cause 3.5% reduction in the cooling capacity.