RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCIESCOPUSKCI등재

        An Optimal Random Carrier Pulse Width Modulation Technique Based on a Genetic Algorithm

        Xu, Jie,Nie, Zi-Ling,Zhu, Jun-Jie The Korean Institute of Power Electronics 2017 JOURNAL OF POWER ELECTRONICS Vol.17 No.2

        Since the carrier sequence is not reproducible in a period of the random carrier pulse width modulation (RCPWM) and a higher harmonic spectrum amplitude is likely to affect the quality of the power supply. In addition, electromagnetic interference (EMI) and mechanical vibration will appear. To solve these problems, this paper has proposed an optimal RCPWM based on a genetic algorithm (GA). In the optimal modulation, the range of the random carrier frequency is taken as a constraint and the reciprocal of the maximum harmonic spectrum amplitude is used as a fitness function to decrease the EMI and mechanical vibration caused by the harmonics concentrated at the carrier frequency and its multiples. Since the problems of the hardware make it difficult to use in practical engineering, this paper has presented a hardware system. Simulations and experiments show that the RCPWM is effective. Studies show that the harmonic spectrum is distributed more uniformly in the frequency domain and that there is no obvious peak in the wave spectra. The proposed method is of great value to research on RCPWM and integrated power systems (IPS).

      • KCI등재

        An Optimal Random Carrier Pulse Width Modulation Technique Based on a Genetic Algorithm

        Jie Xu,Zi-Ling Nie,Jun-Jie Zhu 전력전자학회 2017 JOURNAL OF POWER ELECTRONICS Vol.17 No.2

        Since the carrier sequence is not reproducible in a period of the random carrier pulse width modulation (RCPWM) and a higher harmonic spectrum amplitude is likely to affect the quality of the power supply. In addition, electromagnetic interference (EMI) and mechanical vibration will appear. To solve these problems, this paper has proposed an optimal RCPWM based on a genetic algorithm (GA). In the optimal modulation, the range of the random carrier frequency is taken as a constraint and the reciprocal of the maximum harmonic spectrum amplitude is used as a fitness function to decrease the EMI and mechanical vibration caused by the harmonics concentrated at the carrier frequency and its multiples. Since the problems of the hardware make it difficult to use in practical engineering, this paper has presented a hardware system. Simulations and experiments show that the RCPWM is effective. Studies show that the harmonic spectrum is distributed more uniformly in the frequency domain and that there is no obvious peak in the wave spectra. The proposed method is of great value to research on RCPWM and integrated power systems (IPS).

      • SCIESCOPUSKCI등재

        Mode Switching Smooth Control of Transient Process of Grid-Connected 400 ㎐ Solid-State Power Supply System

        Jun-Jie Zhu,Zi-Ling Nie,Yin-Feng Zhang,Yi Han 전력전자학회 2016 JOURNAL OF POWER ELECTRONICS Vol.16 No.6

        The mode-switching control of transient process is important to grid-connected 400 ㎐ solid-state power supply systems. Therefore, this paper analyzes the principle of on-grid and islanding operation of the system with or without local loads in the grid-connected process and provides a theoretical study of the effect of different switching sequences on the mode-switching transient process. The conclusion is that the mode switch (MS) must be turned on before the solid-state switch (STS) in the on-grid process and that STS must be turned off before the MS in the off-grid process. A strategy of mode-switching smooth control for transient process of the system is proposed, including its concrete steps. The strategy utilizes the average distribution of peak currents and the smooth adjustment of peak currents and phases to achieve a no-shock grid connection. The simulation and experimental results show that the theoretical analysis is correct and that the method is effective.

      • SCIESCOPUSKCI등재

        Mode Switching Smooth Control of Transient Process of Grid-Connected 400 Hz Solid-State Power Supply System

        Zhu, Jun-Jie,Nie, Zi-Ling,Zhang, Yin-Feng,Han, Yi The Korean Institute of Power Electronics 2016 JOURNAL OF POWER ELECTRONICS Vol.16 No.6

        The mode-switching control of transient process is important to grid-connected 400 Hz solid-state power supply systems. Therefore, this paper analyzes the principle of on-grid and islanding operation of the system with or without local loads in the grid-connected process and provides a theoretical study of the effect of different switching sequences on the mode-switching transient process. The conclusion is that the mode switch (MS) must be turned on before the solid-state switch (STS) in the on-grid process and that STS must be turned off before the MS in the off-grid process. A strategy of mode-switching smooth control for transient process of the system is proposed, including its concrete steps. The strategy utilizes the average distribution of peak currents and the smooth adjustment of peak currents and phases to achieve a no-shock grid connection. The simulation and experimental results show that the theoretical analysis is correct and that the method is effective.

      • KCI등재

        Efficiency Optimization of the Active Auxiliary Network in the Phase-Shifted Full-Bridge DC/DC Converter

        Cao Mei-He,Nie Zi-Ling,Ai Sheng,Xu Jie 대한전기학회 2024 Journal of Electrical Engineering & Technology Vol.19 No.3

        Phase-shifted full-bridge DC/DC converter is widely used in the medium and high power DC/DC conversion, and its efciency is an important index to evaluate the performance of the converter. Phase-shifted full-bridge circuit can easily realize the zero voltage switching (ZVS) of the power devices, but there are also problems such as duty-cycle loss and lagging bridge arms that make it difcult to achieve a wide range of ZVS. The application of active auxiliary network can efectively solve the above problems, but it introduces additional loss. This paper analyzes the phase-shifted full-bridge DC/DC converter with active auxiliary network, the duty cycle-loss suppression and the additional circuit loss, optimizes the circuit parameters to reduce the loss and improve the overall efciency of the converter, verifes the theoretical analysis through experiments. Finally, the efciency advantages of the study for high current output applications are clarifed.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼