Controlling Ejection State of a Pneumatic Micro-droplet Generator Through Machine Vision Methods
Fei Wang,Yiwei Wang,Weijie Bao,Hui Zhang,Jiangeng Li,Zhihai Wang 한국정밀공학회 2020 International Journal of Precision Engineering and Vol.21 No.4
Pneumatic micro-droplet ejection is a printing technique that has potential applications in many fi elds, especially in thefi eld of bio-printing. The ejection is via a solenoid valve being briefl y turned on, so that high pressure gas enters the liquidreservoir, forming a gas pressure pulse, forcing the liquid out through a tiny nozzle to form a micro-droplet. For bio-printingapplications, the bio-inks are typically non-standard. The diffi culties are not only that the initial working parameters arediffi cult to set, but also the working conditions change over time in many cases. In order to maintain a stable single-dropejection state, a machine vision based ejection monitoring was designed to obtain the number, positions and sizes of thedroplets for each ejection, and a feedback control is realized by adjusting the “ON” time of the solenoid valve or the gaspressure at the front end of the solenoid valve.