RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        Effects of the Lift Valve Opening Area on Water Hammer Pump Performance and Flow Behavior in the Valve Chamber

        Saito, Sumio,Dejima, Keita,Takahashi, Masaaki,Hijikata, Gaku,Iwamura, Takuya Korean Society for Fluid machinery 2012 International journal of fluid machinery and syste Vol.5 No.3

        Water hammer pumps can effectively use the water hammer phenomenon for water pumping. They are capable of providing an effective fluid transport method in regions without a well-developed social infrastructure. The results of experiments examining the effect of the geometric form of water hammer pumps by considering their major dimensions have been reported. However, these conventional studies have not fully evaluated pump performance in terms of pump head and flow rate, common measures of pump performance. The authors have focused on the effects on the pump performance of various geometric form factors in water hammer pumps. The previous study examined how the hydrodynamic characteristics was affected by the inner diameter ratio of the drive and lift pipes and the angle of the drive pipe, basic form factors of water hammer pumps. The previous papers also showed that the behavior of water hammer pump operation could be divided into four characteristic phases. The behavior of temporal changes in valve chamber and air chamber pressures according to the air volume in the air chamber located downstream of the lift valve was also clarified in connection with changes in water hammer pump performance. In addition, the effects on water hammer pump performance of the length of the spring attached to the drain valve and the drain pipe angle, form factors around the drain valve, were examined experimentally. This study focuses on the form of the lift valve, a major component of water hammer pumps, and examines the effects of the size of the lift valve opening area on water hammer pump performance. It also clarifies the behavior of flow in the valve chamber during water hammer pump operation.

      • KCI등재

        Basic Verification of β-D Glucan in Leukocyte-Rich Plasma for the Diagnosis of Deep Mycosis

        Shimoyama Ken,Kan Shigenori,Takahashi Gaku,Morino Gota,Yamada Yasuhiko,Inoue Yoshihiro,Inada Katsuya,Endo Shigeatsu 대한감염학회 2021 Infection and Chemotherapy Vol.53 No.1

        Background: Currently, supplementary serological testing for β-D glucan (BDG) is often selected to diagnose deep mycosis in care covered by the health insurance in Japan. The Wako method used by our center has low sensitivity, and different studies have used different cut-off values due to factors that cause false positives and false negatives. One possible cause of false negatives is the use of platelet-rich plasma (PRP) as the sample material. Because phagocytic white blood cells (WBC) are precipitated by centrifugation and only plasma is measured, it seems unlikely that the actual amount of BDG is being measured when using PRP. Further, a frequent cause of false positives is contamination from blood products and gauze containing BDG. To resolve these issues, the blood cell separator, hydroxyethyl starch, is used to precipitate only the red blood cells to obtain leukocyte-rich plasma (LRP). We hypothesized that it might be possible to improve the diagnostic rate of deep mycosis by measuring the BDG content of plasma containing WBC and fungal components and by comparing the BDG content of PRP and LRP measured simultaneously. Materials and Methods: Healthy human blood, albumin-added blood, wrung-out gauze fluid-added blood, and fungal solution-added blood were prepared, and PRP and LRP were prepared using hydroxyethyl starch. The BDG content of each sample was measured using the Wako method and compared. In addition, PRP and LRP of fungal-added blood were Gramstained and examined under a microscope, and the number of WBCs and phagocytosed fungi was counted visually and compared. Results: Measuring the BDG content of LRP confirmed that there were no false positives with LRP, and in vitro experiments comparing albumin-added false-positive blood to fungal-added blood showed significant differences between PRP and LRP only in the fungal-added blood. Conclusion: Calculating the BDG-ratio (LRP/PRP) by measuring both LRP and PRP may eliminate false positives and false negatives of true deep mycosis and improve the diagnostic rate.

      • KCI등재후보

        Effects of the Lift Valve Opening Area on Water Hammer Pump Performance and Flow Behavior in the Valve Chamber

        Sumio Saito,Keita Dejima,Masaaki Takahashi,Gaku Hijikata,Takuya Iwamura 한국유체기계학회 2012 International journal of fluid machinery and syste Vol.5 No.3

        Water hammer pumps can effectively use the water hammer phenomenon for water pumping. They are capable of providing an effective fluid transport method in regions without a well-developed social infrastructure. The results of experiments examining the effect of the geometric form of water hammer pumps by considering their major dimensions have been reported. However, these conventional studies have not fully evaluated pump performance in terms of pump head and flow rate, common measures of pump performance. The authors have focused on the effects on the pump performance of various geometric form factors in water hammer pumps. The previous study examined how the hydrodynamic characteristics was affected by the inner diameter ratio of the drive and lift pipes and the angle of the drive pipe, basic form factors of water hammer pumps. The previous papers also showed that the behavior of water hammer pump operation could be divided into four characteristic phases. The behavior of temporal changes in valve chamber and air chamber pressures according to the air volume in the air chamber located downstream of the lift valve was also clarified in connection with changes in water hammer pump performance. In addition, the effects on water hammer pump performance of the length of the spring attached to the drain valve and the drain pipe angle, form factors around the drain valve, were examined experimentally. This study focuses on the form of the lift valve, a major component of water hammer pumps, and examines the effects of the size of the lift valve opening area on water hammer pump performance. It also clarifies the behavior of flow in the valve chamber during water hammer pump operation.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼