RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Lymph node yield in node-negative patients predicts cancer specific survival following radical cystectomy for transitional cell carcinoma

        Jack Crozier,Nathan Papa,Marlon Perera,Michael Stewart,Jeremy Goad,Shomik Sengupta,Damien Bolton,Nathan Lawrentschuk 대한비뇨의학회 2017 Investigative and Clinical Urology Vol.58 No.6

        Purpose: To determine the oncological implications of increased nodal dissection in node-negative bladder cancer during radical cystectomy in a contemporary Australian series. Materials and Methods: We performed a multicenter retrospective study, including more than 40 surgeons across 5 sites over a 10-year period. We identified 353 patients with primary bladder cancer undergoing radical cystectomy. Extent of lymphadenectomy was defined as follows; limited pelvic lymph node dissection (PLND) (perivesical, pelvic, and obturator), standard PLND (internal and external iliac) and extended PLND (common iliac). Multivariable cox proportional hazards and logistic regression models were used to determine LNY effect on cancer-specific survival. Results: Over the study period, the extent of dissection and lymph node yield increased considerably. In node-negative patients, lymph node yield (LNY) conferred a significantly improved cancer-specific survival. Compared to cases where LNY of 1 to 5 nodes were taken, the hazard ratio (HR) for 6 to 15 nodes harvested was 0.78 (95% confidence interval [CI], 0.43–1.39) and for greater than 15 nodes the HR was 0.31 (95% CI, 0.17–0.57), adjusted for age, sex, T stage, margin status, and year of surgery. The predicted probability of cancer-specific death within 2 years of cystectomy was 16% (95% CI, 13%–19%) with 10 nodes harvested, falling to 5.5% (95% CI, 0%–12%) with 30 nodes taken. Increasing harvest in all PLND templates conferred a survival benefit. Conclusions: The findings of the current study highlight the improved oncological outcomes with increased LNY, irrespective of the dissection template. Further prospective research is needed to aid LND data interpretation.

      • KCI등재

        The use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy

        Michael Chao,Huong Ho,Daryl Lim Joon,Yee Chan,Sandra Spencer,Michael Ng,Jason Wasiak,Nathan Lawrentschuk,Kevin McMillan,Shomik Sengupta,Alwin Tan,George Koufogiannis,Margaret Cokelek,Farshad Foroudi,T 대한방사선종양학회 2019 Radiation Oncology Journal Vol.37 No.1

        Purpose: The aim of this retrospective study was to investigate the use of a radiopaque tissue fiducial marker (TFM) in the treatment of prostate cancer patients who undergo post-prostatectomy radiotherapy (PPRT). TFM safety, its role and benefit in quantifying the set-up uncertainties in patients undergoing PPRT image-guided radiotherapy were assessed. Materials and Methods: A total of 45 consecutive PPRT patients underwent transperineal implantation of TFM at the level of vesicourethral anastomosis in the retrovesical tissue prior to intensity-modulated radiotherapy. Prostate bed motion was calculated by measuring the position of the TFM relative to the pelvic bony anatomy on daily cone-beam computed tomography. The stability and visibility of the TFM were assessed in the initial 10 patients. Results: No postoperative complications were recorded. A total of 3,500 images were analysed. The calculated prostate bed motion for bony landmark matching relative to TFM were 2.25 mm in the left-right, 5.89 mm in the superior-inferior, and 6.59 mm in the anterior-posterior directions. A significant 36% reduction in the mean volume of rectum receiving 70 Gy (rV70) was achieved for a uniform planning target volume (PTV) margin of 7 mm compared with the Australian and New Zealand Faculty of Radiation Oncology Genito-Urinary Group recommended PTV margin of 10 mm. Conclusion: The use of TFM was safe and can potentially eliminate set-up errors associated with bony landmark matching, thereby allowing for tighter PTV margins and a consequent favourable reduction in dose delivered to the bladder and rectum, with potential improvements in toxicities.

      • SCOPUSKCI등재

        The use of tissue fiducial markers in improving the accuracy of post-prostatectomy radiotherapy

        Chao, Michael,Ho, Huong,Joon, Daryl Lim,Chan, Yee,Spencer, Sandra,Ng, Michael,Wasiak, Jason,Lawrentschuk, Nathan,McMillan, Kevin,Sengupta, Shomik,Tan, Alwin,Koufogiannis, George,Cokelek, Margaret,Foro The Korean Society for Radiation Oncology 2019 Radiation Oncology Journal Vol.37 No.1

        Purpose: The aim of this retrospective study was to investigate the use of a radiopaque tissue fiducial marker (TFM) in the treatment of prostate cancer patients who undergo post-prostatectomy radiotherapy (PPRT). TFM safety, its role and benefit in quantifying the set-up uncertainties in patients undergoing PPRT image-guided radiotherapy were assessed. Materials and Methods: A total of 45 consecutive PPRT patients underwent transperineal implantation of TFM at the level of vesicourethral anastomosis in the retrovesical tissue prior to intensity-modulated radiotherapy. Prostate bed motion was calculated by measuring the position of the TFM relative to the pelvic bony anatomy on daily cone-beam computed tomography. The stability and visibility of the TFM were assessed in the initial 10 patients. Results: No postoperative complications were recorded. A total of 3,500 images were analysed. The calculated prostate bed motion for bony landmark matching relative to TFM were 2.25 mm in the left-right, 5.89 mm in the superior-inferior, and 6.59 mm in the anterior-posterior directions. A significant 36% reduction in the mean volume of rectum receiving 70 Gy (rV<sub>70</sub>) was achieved for a uniform planning target volume (PTV) margin of 7 mm compared with the Australian and New Zealand Faculty of Radiation Oncology Genito-Urinary Group recommended PTV margin of 10 mm. Conclusion: The use of TFM was safe and can potentially eliminate set-up errors associated with bony landmark matching, thereby allowing for tighter PTV margins and a consequent favourable reduction in dose delivered to the bladder and rectum, with potential improvements in toxicities.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼