RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Influence of receiver bandwidth on MRI artifacts caused by orthodontic brackets composed of different alloys

        Abdala-Junior Reinaldo,No-Cortes Juliana,Arita Emiko Saito,Ackerman Jerome L.,da Silva Renan Lúcio Berbel,Kim Jun Ho,Cortes Arthur Rodriguez Gonzalez 대한영상치의학회 2021 Imaging Science in Dentistry Vol.51 No.4

        Purpose: The aim of this in vitro study was to assess the role of bandwidth on the area of magnetic resonance imaging (MRI) artifacts caused by orthodontic appliances composed of different alloys, using different pulse sequences in 1.5 T and 3.0 T magnetic fields. Materials and Methods: Different phantoms containing orthodontic brackets (ceramic, ceramic bracket with a stainless-steel slot, and stainless steel) were immersed in agar gel and imaged in 1.5 T and 3.0 T MRI scanners. Pairs of gradient-echo (GE), spin-echo (SE), and ultrashort echo time (UTE) pulse sequences were used differing in bandwidth only. The area of artifacts from orthodontic devices was automatically estimated from pixel value thresholds within a region of interest (ROI). Mean values for similar pulse sequences differing in bandwidth were compared at 1.5 T and 3.0 T using analysis of variance. Results: The comparison of groups revealed a significant inverse association between bandwidth values and artifact areas of the stainless-steel bracket and the self-ligating ceramic bracket with a stainless-steel slot (P<0.05). The areas of artifacts from the ceramic bracket were the smallest, but were not reduced significantly in pulse sequences with higher bandwidth values (P<0.05). Significant differences were also observed between 1.5 T and 3.0 T MRI using SE and UTE, but not using GE 2-dimensional or 3-dimensional pulse sequences. Conclusion: Higher receiver bandwidth might be indicated to prevent artifacts from orthodontic appliances in 1.5 T and 3.0 T MRI using SE and UTE pulse sequences.

      • SCOPUSKCI등재

        Influence of receiver bandwidth on MRI artifacts caused by orthodontic brackets composed of different alloys

        Abdala-Junior, Reinaldo,No-Cortes, Juliana,Arita, Emiko Saito,Ackerman, Jerome L.,da Silva, Renan Lucio Berbel,Kim, Jun Ho,Cortes, Arthur Rodriguez Gonzalez Korean Academy of Oral and Maxillofacial Radiology 2021 Imaging Science in Dentistry Vol.51 No.-

        Purpose: The aim of this in vitro study was to assess the role of bandwidth on the area of magnetic resonance imaging (MRI) artifacts caused by orthodontic appliances composed of different alloys, using different pulse sequences in 1.5 T and 3.0 T magnetic fields. Materials and Methods: Different phantoms containing orthodontic brackets (ceramic, ceramic bracket with a stainless-steel slot, and stainless steel) were immersed in agar gel and imaged in 1.5 T and 3.0 T MRI scanners. Pairs of gradient-echo (GE), spin-echo (SE), and ultrashort echo time (UTE) pulse sequences were used differing in bandwidth only. The area of artifacts from orthodontic devices was automatically estimated from pixel value thresholds within a region of interest (ROI). Mean values for similar pulse sequences differing in bandwidth were compared at 1.5 T and 3.0 T using analysis of variance. Results: The comparison of groups revealed a significant inverse association between bandwidth values and artifact areas of the stainless-steel bracket and the self-ligating ceramic bracket with a stainless-steel slot(P<0.05). The areas of artifacts from the ceramic bracket were the smallest, but were not reduced significantly in pulse sequences with higher bandwidth values(P<0.05). Significant differences were also observed between 1.5 T and 3.0 T MRI using SE and UTE, but not using GE 2-dimensional or 3-dimensional pulse sequences. Conclusion: Higher receiver bandwidth might be indicated to prevent artifacts from orthodontic appliances in 1.5 T and 3.0 T MRI using SE and UTE pulse sequences.

      • SCOPUSKCI등재

        Comparison of the diagnostic performance of panoramic and occlusal radiographs in detecting submandibular sialoliths

        Kim, Jun Ho,Aoki, Eduardo Massaharu,Cortes, Arthur Rodriguez Gonzalez,Abdala-Junior, Reinaldo,Asaumi, Junichi,Arita, Emiko Saito Korean Academy of Oral and Maxillofacial Radiology 2016 Imaging Science in Dentistry Vol.46 No.2

        Purpose: The aim of this study was to assess and compare the diagnostic performance of panoramic and occlusal radiographs in detecting submandibular sialoliths. Materials and Methods: A total of 40 patients (20 cases and 20 controls) were included in this retrospective study. Cases were defined as subjects with a submandibular sialolith confirmed by computed tomography (CT), whereas controls did not have any submandibular calcifications. Three observers with different expertise levels assessed panoramic and occlusal radiographs of all subjects for the presence of sialoliths. Intraobserver and interobserver agreement were assessed using the kappa test. Sensitivity, specificity, accuracy, positive and negative predictive values, and the diagnostic odds ratio of panoramic and occlusal radiographs in screening for submandibular sialoliths were calculated for each observer. Results: The sensitivity and specificity values for occlusal and panoramic radiographs all ranged from 80% to 100%. The lowest values of sensitivity and specificity observed among the observers were 82.6% and 80%, respectively (P=0.001). Intraobserver and interobserver agreement were higher for occlusal radiographs than for panoramic radiographs, although panoramic radiographs demonstrated a higher overall accuracy. Conclusion: Both panoramic and occlusal radiographic techniques displayed satisfactory diagnostic performance and should be considered before using a CT scan to detect submandibular sialoliths.

      • SCOPUSKCI등재

        Correlation between magnetic resonance imaging and cone-beam computed tomography for maxillary sinus graft assessment

        Laurino, Fernando Antonio Reis,Choi, Isabela Goulart Gil,Kim, Jun Ho,Gialain, Ivan Onone,Ferraco, Renato,Haetinger, Rainer Guilherme,Pinhata-Baptista, Otavio Henrique,Abdala-Junior, Reinaldo,Costa, Cl Korean Academy of Oral and Maxillofacial Radiology 2020 Imaging Science in Dentistry Vol.50 No.2

        Purpose: Little is known regarding the accuracy of clinical magnetic resonance imaging (MRI) protocols with acceptable scan times in sinus graft assessment. The aim of this study was to evaluate the correlations between MRI and cone-beam computed tomographic (CBCT) measurements of maxillary sinus grafts using 2 different clinical MRI imaging protocols. Materials and Methods: A total of 15 patients who underwent unilateral sinus lift surgery with biphasic calcium phosphate were included in this study. CBCT, T1-weighted MRI, and T2-weighted MRI scans were taken 6 months after sinus lift surgery. Linear measurements of the maximum height and buccolingual width in coronal images, as well as the maximum anteroposterior depth in sagittal images, were performed by 2 trained observers using CBCT and MRI Digital Imaging and Communication in Medicine files. Micro-computed tomography (micro-CT) was also performed to confirm the presence of bone tissue in the grafted area. Correlations between MRI and CBCT measurements were assessed with the Pearson test. Results: Significant correlations between CBCT and MRI were found for sinus graft height (T1-weighted, r=0.711 and P<0.05; T2-weighted, r=0.713 and P<0.05), buccolingual width (T1-weighted, r=0.892 and P<0.05; T2-weighted, r=0.956 and P<0.05), and anteroposterior depth (T1-weighted, r=0.731 and P<0.05; T2-weighted, r=0.873 and P<0.05). The presence of bone tissue in the grafted areas was confirmed via micro-CT. Conclusion: Both MRI pulse sequences tested can be used for sinus graft measurements, as strong correlations with CBCT were found. However, correlations between T2-weighted MRI and CBCT were slightly higher than those between T1-weighted MRI and CBCT.

      • KCI등재

        Correlation between magnetic resonance imaging and cone-beam computed tomography for maxillary sinus graft assessment

        Fernando Antonio Reis Laurino,Isabela Goulart Gil Choi,Jun Ho Kim,Ivan Onone Gialain,Renato Ferraço,Rainer Guilherme Haetinger,Otavio Henrique Pinhata-Baptista,Reinaldo Abdala-Junior,Claudio Costa,Art 대한영상치의학회 2020 Imaging Science in Dentistry Vol.50 No.2

        Purpose: Little is known regarding the accuracy of clinical magnetic resonance imaging (MRI) protocols with acceptable scan times in sinus graft assessment. The aim of this study was to evaluate the correlations between MRI and cone-beam computed tomographic (CBCT) measurements of maxillary sinus grafts using 2 different clinical MRI imaging protocols. Materials and Methods: A total of 15 patients who underwent unilateral sinus lift surgery with biphasic calcium phosphate were included in this study. CBCT, T1-weighted MRI, and T2-weighted MRI scans were taken 6 months after sinus lift surgery. Linear measurements of the maximum height and buccolingual width in coronal images, as well as the maximum anteroposterior depth in sagittal images, were performed by 2 trained observers using CBCT and MRI Digital Imaging and Communication in Medicine files. Microcomputed tomography (micro-CT) was also performed to confirm the presence of bone tissue in the grafted area. Correlations between MRI and CBCT measurements were assessed with the Pearson test. Results: Significant correlations between CBCT and MRI were found for sinus graft height (T1-weighted, r=0.711 and P<0.05; T2-weighted, r=0.713 and P<0.05), buccolingual width (T1-weighted, r=0.892 and P<0.05; T2-weighted, r=0.956 and P<0.05), and anteroposterior depth (T1-weighted, r=0.731 and P<0.05; T2-weighted, r=0.873 and P<0.05). The presence of bone tissue in the grafted areas was confirmed via micro-CT. Conclusion: Both MRI pulse sequences tested can be used for sinus graft measurements, as strong correlations with CBCT were found. However, correlations between T2-weighted MRI and CBCT were slightly higher than those between T1-weighted MRI and CBCT.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼