RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Electroacupuncture for the Treatment of Calcific Tendonitis. A Pilot Study

        Georgios Papadopoulos,Alexandros Mavrodontidis,Antonia Liarmakopoulou,Petros Tzimas,Georgios Angelidakis,Panagiotis Koulouvaris,Anastasios Petrou 사단법인약침학회 2018 Journal of Acupuncture & Meridian Studies Vol.11 No.2

        Current treatment for calcific tendonitis consists of arm rest, antiinflammatory medications, and corticosteroid injections. If unsuccessful, a lot of clinicians suggest several physiotherapy modalities, such as shockwave therapy and electrotherapy. The purpose of our study was to assess the efficacy of electroacupuncture, as a substitute for failed medical treatment in calcific tendonitis. In a pilot study, we prospectively followed 10 patients treated with electroacupuncture for calcific tendonitis who failed to respond to medical treatment. Its efficacy was assessed by evaluating the level of pain, the Beck Depression Inventory, the range of active elbow mobility, and by repeated radiological evaluation of the course of calcific deposits. All clinical and radiological observations were recorded before and within 6 months after the onset of treatment. After electroacupuncture treatment (2 Hz, 180 mA for 30–60 seconds at GB21, GB34, LI4, LI 14, LI15, TW5, TW14, Chien Chien SI9, SI12, S37, S38), the visual analog score decreased notably, and the range of motion returned to normal. Radiological evaluation demonstrated almost complete absorption of calcific deposits within 6 months, after treatment. We conclude that electroacupuncture relieved skeletal pain, improved the quality of patient's life, and contributed to total regression of the calcific depositions in followed patients. So, electroacupuncture may be a valuable treatment option for calcific tendonitis, when medical treatment fails to relieve symptoms.

      • KCI등재

        Auricular Acupuncture Analgesia in Thoracic Trauma: A Case Report

        Georgios S. Papadopoulos,Petros Tzimas,Antonia Liarmakopoulou,Anastasios M. Petrou 사단법인약침학회 2017 Journal of Acupuncture & Meridian Studies Vol.10 No.1

        We report a case of thoracic trauma (rib fractures with pneumothorax and pulmonary contusions) with severe chest pain leading to ineffective ventilation and oxygenation. The patient presented to our emergency department. The patient had chronic obstructive pulmonary disease and was completely unable to take deep breaths and clear secretions from his bronchial tree. After obtaining informed consent, we applied auricular acupuncture to ameliorate pain and hopefully improve his functional ability to cough and breathe deeply. Within a few minutes, his pain scores diminished considerably, and his ventilation and oxygenation indices improved to safe limits. Auricular acupuncture analgesia lasted for several hours. Parallel to pain reduction, hemodynamic disturbances and anxiety significantly resolved. A second treatment nearly a day later resulted in almost complete resolution of pain that lasted at least 5 days and permitted adequate ventilation, restored oxygenation, and some degree of mobilization (although restricted due to a compression fracture of a lumbar vertebra). Nonopioid and opioid analgesics were sparsely used in low doses during the entire hospitalization period. Hemodynamic alterations and anxiety also decreased, and the patient was soon ready to be discharged.

      • SCIESCOPUSKCI등재

        Experimental investigation on bubble behaviors in a water pool using the venturi scrubbing nozzle

        Choi, Yu Jung,Kam, Dong Hoon,Papadopoulos, Petros,Lind, Terttaliisa,Jeong, Yong Hoon Korean Nuclear Society 2021 Nuclear Engineering and Technology Vol.53 No.6

        The containment filtered venting system (CFVS) filters the atmosphere of the containment building and discharges a part of it to the outside environment to prevent containment overpressure during severe accidents. The Korean CFVS has a tank that filters fission products from the containment atmosphere by pool scrubbing, which is the primary decontamination process; however, prediction of its performance has been done based on researches conducted under mild conditions than those of severe accidents. Bubble behavior in a pool is a key parameter of pool scrubbing. Therefore, the bubble behavior in the pool was analyzed under various injection flow rates observed at the venturi nozzles used in the Korean CFVS using a wire-mesh sensor. Based on the experimental results, void fraction model was modified using the existing correlation, and a new bubble size prediction model was developed. The modified void fraction model agreed well with the obtained experimental data. However, the newly developed bubble size prediction model showed different results to those established in previous studies because the venturi nozzle diameter considered in this study was larger than those in previous studies. Therefore, this is the first model that reflects actual design of a venturi scrubbing nozzle.

      • KCI등재

        Bubbly, Slug and Annular Two-Phase Flow in Tight-Lattice Sub-Channels

        Horst-Michael Prasser,Christian Bolesch,Kerstin Cramer,Daisuke Ito,Petros Papadopoulos,Abhishek Saxena,Robert Zboray 한국원자력학회 2016 Nuclear Engineering and Technology Vol.48 No.4

        An overview is given on the work of the Laboratory of Nuclear Energy Systems at ETH, Zurich (ETHZ) and of the Laboratory of Thermal Hydraulics at Paul Scherrer Institute (PSI), Switzerland on tight-lattice bundles. Two-phase flow in subchannels of a tight triangular lattice was studied experimentally and by computational fluid dynamics simulations. Two adiabatic facilities were used: (1) a vertical channel modeling a pair of neighboring subchannels; and (2) an arrangement of four subchannels with one subchannel in the center. The first geometry was equipped with two electrical film sensors placed on opposing rod surfaces forming the subchannel gap. They recorded 2D liquid film thickness distributions on a domain of 16 × 64 measuring points each, with a time resolution of 10 kHz. In the bubbly and slug flow regime, information on the bubble size, shape, and velocity and the residual liquid film thickness underneath the bubbles were obtained. The second channel was investigated using cold neutron tomography, which allowed the measurement of average liquid film profiles showing the effect of spacer grids with vanes. The results were reproduced by large eddy simulation + volume of fluid. In the outlook, a novel nonadiabatic subchannel experiment is introduced that can be driven to steady-state dryout. A refrigerant is heated by a heavy water circuit, which allows the application of cold neutron tomography

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼