http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Ganjali, Mohammad Reza,Norouzi, Parviz,Shirvani Arani, Simindokht,Salavati Niasari, Masoud Korean Chemical Society 2005 Bulletin of the Korean Chemical Society Vol.26 No.11
In this study a novel triiodide ion-selective electrode based on a charge transfer complex of iodine and Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone (ICT), as a membrane carrier was prepared. The electrode has a linear dynamic range between 1.0 ${\times}$ $10^{-2}$ and 5.0 ${\times}$ $10^{-7}$ M, with a Nernstian slope of 58. 99 ${\pm}$ 0.3 mV $decade^{-1}$ and detection limit of 3.0 ${\times}$ $10 ^{-7}$ M. The potentiometric response of the proposed sensor is independent of the pH of the solution in the pH range of 3.0-10.0. The electrode possesses the advantages of short conditioning time, fast response time, and especially, very good selectivity over a large number of common organic and inorganic anions. The electrode can be used for at least 6 months without any considerable divergences in the potentials. It was used as an indicator electrode in potentiometric titration of triiodide ion with thiosulfate.
Ganjali, Mohammad Reza,Norouzi, Parviz,Tamaddon, Atefeh,Husain, Syed Waqif Korean Chemical Society 2006 Bulletin of the Korean Chemical Society Vol.27 No.9
In this work the construction of a novel poly(vinyl chloride) membrane sensor based on 2,2'-dianiline disulfide (DADS) as a neutral carrier, o-nitrophenyloctyl ether (NPOE) as a plasticizer and sodium tetraphenyl borate (NaTPB) as an anionic site with unique selectivity towards Tm(III) ions is reported. The electrode has a linear dynamic range between $1.0\;{\times}\;10^{-6}$ and $1.0\;{\times}\;10^{-2}$ M, with a nice Nernstian slope of 19.5 ${\pm}$ 0.3 mV per decade and a detection limit of $4.0\;{\times}\;10^{-7}$ M at the pH range of 4.8-8.5. It has a very fast response time (<15 s) in the whole concentration range, and can be used for at least 4 weeks without any considerable divergence in the electrode potentials. The proposed sensor revealed comparatively good selectivity with respect to most common metal ions, and especially lanthanide ions. It was used as an indicator electrode in the potentiometric titration of Tm(III) ions with EDTA and in direct determination of concentration of Tm(III) ions in binary mixtures. It was also applied in determination of fluoride ions in mouth wash preparations.
Mohammad Reza Ganjali*,Parviz Norouzi,Atefeh Tamaddon,Syed Waqif Husain 대한화학회 2006 Bulletin of the Korean Chemical Society Vol.27 No.9
In this work the construction of a novel poly(vinyl chloride) membrane sensor based on 2,2'-dianiline disulfide (DADS) as a neutral carrier, o-nitrophenyloctyl ether (NPOE) as a plasticizer and sodium tetraphenyl borate (NaTPB) as an anionic site with unique selectivity towards Tm(III) ions is reported. The electrode has a linear dynamic range between 1.0 10-6 and 1.0 10-2 M, with a nice Nernstian slope of 19.5 0.3 mV per decade and a detection limit of 4.0 10-7 M at the pH range of 4.8-8.5. It has a very fast response time (<15 s) in the whole concentration range, and can be used for at least 4 weeks without any considerable divergence in the electrode potentials. The proposed sensor revealed comparatively good selectivity with respect to most common metal ions, and especially lanthanide ions. It was used as an indicator electrode in the potentiometric titration of Tm(III) ions with EDTA and in direct determination of concentration of Tm(III) ions in binary mixtures. It was also applied in determination of fluoride ions in mouth wash preparations.
Ganjali, Mohammad Reza,Norouzi, Parviz,Yousefian, Nasrin,Faridbod, Farnoush,Adib, Mehdi Korean Chemical Society 2006 Bulletin of the Korean Chemical Society Vol.27 No.10
A La (III) ion-selective membrane sensor has been fabricated from poly vinyl chloride (PVC) matrix membrane, containing 3-hydroxy-N'-(pyridin-2-ylmethylene)-2-naphthohydrazide (HPMN) as a neutral carrier, potassium tetrakis (p-chlorophenyl) borate (KTpClPB) as an anionic excluder and ortho-nitrophenyloctyl ether (NPOE) as a plasticizing solvent mediator. The effects of membrane composition and pH as well as the influence of the anionic additive on the response properties were investigated. The sensor with 30% PVC, 62% solvent mediator, 6% ionophore and 2% anionic additive, shows the best potentiometric response characteristics. It displays a Nernstian behavior (19.2 mV per decade) across the range of $1.0{\times}10^{-2}-1.0{\times}10^{-7}$ M. The detection limit of the electrode is $7.0{\times}10^{-8}$ M ($\sim$10 ng/mL) and the response time is 15 s from $1.0{\times}10^{-2}$ up to $1.0{\times}10^{-4} $M and 30 s in the range of $1.0 {\times}10^{-5}-1.0{\times}10^{-7}$ M. The sensor can be used in the pH values of 3.0-9.0 for about seven weeks. The membrane sensor was used as an indicator electrode in the potentiometric titration of lanthanum ions with EDTA. It was successfully applied to the lanthanum determination in some mouth wash preparations.
La(III) Selective Membrane Sensor Based on a New N-N Schiff's Base
Mohammad Reza Ganjali*,Parisa Matloobi,Maryam Ghorbani,Parviz Norouzi,Masoud Salavati-Niasari 대한화학회 2005 Bulletin of the Korean Chemical Society Vol.26 No.1
Bis(2-methylbenzaldehyde)butane-2,3-dihydrazone(TDSB) was used as new N-N Schiff's base which plays the role of an excellent ion carrier in the construction of a La(III) membrane sensor. The best performance was obtained with a membrane containing, 30% poly(vinyl chloride), 60% benzyl acetate, 6% TDSB and 4% sodium tetraphenyl borate. This sensor reveals a very good selectivity towards La(III) ions over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The proposed electrode exhibits a Nernstian behavior (with slope of 19.8 mV per decade) over a wide concentration range (1.0 × 10−5-1.0 × 10−1 M). The detection limit of the sensor is 7.0 × 10−6 M. It has a very short response time, in the whole concentration range (~5 s), and can be used for at least twelve weeks in the pH range of 3.0-9.4. The proposed sensor was successfully applied as an indicator electrode for the potentiometric titration of a La(III) solution,with EDTA. It was also successfully applied in the determination of fluoride ions in three mouth wash preparations.
Mohammad Reza Ganjali,Parviz Norouzi,Simindokht Shirvani-Arani,Masoud Salavati-Niasari 대한화학회 2005 Bulletin of the Korean Chemical Society Vol.26 No.11
In this study a novel triiodide ion-selective electrode based on a charge transfer complex of iodine and Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone (ICT), as a membrane carrier was prepared. The electrode has a linear dynamic range between 1.0 × 102 and 5.0 × 107 M, with a Nernstian slope of 58. 99 ± 0.3 mV decade1 and detection limit of 3.0 × 107 M. The potentiometric response of the proposed sensor is independent of the pH of the solution in the pH range of 3.0-10.0. The electrode possesses the advantages of short conditioning time, fast response time, and especially, very good selectivity over a large number of common organic and inorganic anions. The electrode can be used for at least 6 months without any considerable divergences in the potentials. It was used as an indicator electrode in potentiometric titration of triiodide ion with thiosulfate.
Zn2+ PVC-based Membrane Sensor Based on 3-[(2-Furylmethylene)amino]-2-thioxo-1,3-thiazolidin-4-one
Mohammad Reza Ganjali*,Hassan Ali Zamani,Parviz Norouzi,Mehdi Adib,Morteza Rezapour,Mohammad Aceedy 대한화학회 2005 Bulletin of the Korean Chemical Society Vol.26 No.4
The 3-[(2-furylmethylene)amino]-2-thioxo-1,3-thiazolidin-4-one (FTT) was used as an excellent ionophore in construction of a Zn2+ PVC-based membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 62% nitrobenzen (NB), 3% FTT and 5% sodium tetraphenyl borate (TBP). This membrane sensor shows very good selectivity and sensitivity towards Zn2+ over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The membrane sensor revealed a great enhancement in selectivity coefficients for Zn2+ ions, in comparison to the previously reported Zn2+ membrane sensors. Theoretical studies also showed the selective interaction of TFF and Zn2+ ions. The proposed membrane sensor exhibits a Nernstian behavior (with slope of 29.3 ± 0.3 mV per decade) over a wide concentration range (1.0´106-1.0´102) with a detection limit of 8.5´107 M (52 ng mL1). It shows relatively fast response time, in the whole concentration range (< 20 s), and can be used for at least 10 weeks in a pH range of 3.0-7.0. The proposed membrane sensor was successfully used in direct determination of Zn2+ ions in wastewater of industrial zinc electroplating companies, and also as an indicator electrode in titration with EDTA.
Mohammad Reza Ganjali*,Parviz Norouzi,Nasrin Yousefian,Farnoush Faridbod,Mehdi Adib 대한화학회 2006 Bulletin of the Korean Chemical Society Vol.27 No.10
A La (III) ion-selective membrane sensor has been fabricated from poly vinyl chloride (PVC) matrix membrane, containing 3-hydroxy-N'-(pyridin-2-ylmethylene)-2-naphthohydrazide (HPMN) as a neutral carrier, potassium tetrakis (p-chlorophenyl) borate (KTpClPB) as an anionic excluder and ortho-nitrophenyloctyl ether (NPOE) as a plasticizing solvent mediator. The effects of membrane composition and pH as well as the influence of the anionic additive on the response properties were investigated. The sensor with 30% PVC, 62% solvent mediator, 6% ionophore and 2% anionic additive, shows the best potentiometric response characteristics. It displays a Nernstian behavior (19.2 mV per decade) across the range of 1.0 ´ 10-2 - 1.0 ´ 10-7 M. The detection limit of the electrode is 7.0 ´ 10-8 M (~10 ng/mL) and the response time is 15 s from 1.0 ´ 10-2 up to 1.0 ´ 10-4 M and 30 s in the range of 1.0 ´ 10-5-1.0 ´ 10-7 M. The sensor can be used in the pH values of 3.0-9.0 for about seven weeks. The membrane sensor was used as an indicator electrode in the potentiometric titration of lanthanum ions with EDTA. It was successfully applied to the lanthanum determination in some mouth wash preparations.