http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Gabriel Barreto Antonino,Ana Paula de Lima Ferreira,Eduardo Jose Nepomuceno Montenegro,Alberto Galvão de Moura Filho,Arthur Felipe Freire da Silva,Maria das Graças Rodrigues de Araújo 사단법인약침학회 2020 Journal of Acupuncture & Meridian Studies Vol.13 No.5
The present study aims to propose a protocol to verify the efficacy and acute effects of traditional Chinese acupuncture, dry needling, and the rest in peripheral acute fatigue (PAF) induced by intermittent isometric contractions of the nondominant biceps brachii (BB) of nonphysically active men in a randomized, single-blind clinical trial assessed with surface electromyography, contraction time in seconds, infrared thermal imaging, and visual analog scale applied to the PAF. These instruments will evaluate the median frequency, endurance time, temperature (°C), and perceived fatigue in BB of the volunteers. The measurements will be collected in four moments (Test 0, 01, 02, and 03) divided between the beginning and the end of two sets of exercises (Exercises 01 and 02) of intermittent isometric contractions. Trial identifier: NCT03448120 in www.clinicaltrials.gov.
Ribeiro Emanuelle Olympia Silva,Gosselink Rik,Moura Lizandra Eveline da Silva,Correia Raissa Farias,Leite Wagner Souza,Araújo Maria das Graças Rodrigues de,Andrade Armele Dornelas de,Brandão Daniella 대한중환자의학회 2022 Acute and Critical Care Vol.37 No.4
Background: Respiratory muscle strength in patients with an artificial airway is commonly assessed as the maximal inspiratory pressure (MIP) and is measured using analogue or digital manometers. Recently, new electronic loading devices have been proposed to measure respiratory muscle strength. This study evaluates the agreement between the MIPs measured by a digital manometer and those according to an electronic loading device in patients being weaned from mechanical ventilation.Methods: In this prospective study, the standard MIP was obtained using a protocol adapted from Marini, in which repetitive inspiratory efforts were performed against an occluded airway with a one-way valve and were recorded with a digital manometer for 40 seconds (MIPDM). The MIP measured using the electronic loading device (MIPELD) was obtained from repetitively tapered flow resistive inspirations sustained for at least 2 seconds during a 40-second test. The agreement between the results was verified by a Bland-Altman analysis.Results: A total of 39 subjects (17 men, 55.4±17.7 years) was enrolled. Although a strong correlation between MIPDM and MIPELD (R=0.73, P<0.001) was observed, the Bland-Altman analysis showed a high bias of –47.4 (standard deviation, 22.3 cm H2O; 95% confidence interval, –54.7 to –40.2 cm H2O).Conclusions: The protocol of repetitively tapering flow resistive inspirations to measure the MIP with the electronic loading device is not in agreement with the standard protocol using one-way valve inspiratory occlusion when applied in poorly cooperative patients being weaned from mechanical ventilation.