http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
An Unusual Cause of Hemoptysis: Congenital Absence of the Right Pulmonary Artery in a Young Male
Chan Victor Siang Hua,Ma Wai Han,Ho Wai Yin,Chan Carmen Wing Sze,Cheung Stephen Chi Wai,Lam Wendy Wai Man 아시아심장혈관영상의학회 2019 Cardiovascular Imaging Asia Vol.3 No.1
Unilateral absent pulmonary artery (UAPA) is rare and can occur in association with cardiovascular anomalies or in isolation. Herein, we describe a case of isolated UAPA in a 14-yearold male patient who presented with hemoptysis secondary to abnormal hypertrophy of collateral vasculature. The patient was successfully treated by endovascular embolization with polyvinyl alcohol particles.
Bernard Yan,Hans Tu,Christina Lam,Corey Swift,Ma Sze Ho,Vincent C.T. Mok,Yi Sui,David Sharpe,Darshan Ghia,Jim Jannes,Stephen Davis,Xinfeng Liu,Ben Freedman 대한뇌졸중학회 2020 Journal of stroke Vol.22 No.3
Background and Purpose Paroxysmal atrial fibrillation (PAF) underlying acute stroke frequently evades detection by standard practice, considered to be a combination of routine electrocardiogram (ECG) monitoring, and 24-hour Holter recordings. We hypothesized that nurse-led in-hospital intermittent monitoring approach would increase PAF detection rate. Methods We recruited patients hospitalised for stroke/transient ischemic attack, without history of atrial fibrillation (AF), in a prospective multi-centre observational study. Patients were monitored using a smartphone-enabled handheld ECG (iECG) during routine nursing observations, and underwent 24-hour Holter monitoring according to local practice. The primary outcome was comparison of AF detection by nurse-led iECG versus Holter monitoring in patients who received both tests: secondary outcome was oral anticoagulant commencement at 3-month following PAF detection. Results One thousand and seventy-nine patients underwent iECG monitoring: 294 had iECG and Holter monitoring. AF was detected in 25/294 (8.5%) by iECG, and 8/294 (2.8%) by 24-hour Holter recordings (P<0.001). Median duration from stroke onset to AF detection for iECG was 3 days (interquartile range [IQR], 2 to 6) compared with 7 days (IQR, 6 to 10) for Holter recordings (P=0.02). Of 25 patients with AF detected by iECG, 11 were commenced on oral anticoagulant, compared to 5/8 for Holter. AF was detected in 8.8% (69/785 patients) who underwent iECG recordings only (P=0.8 vs. those who had both iECG and 24-hour Holter). Conclusions Nurse-led in-hospital iECG surveillance after stroke is feasible and effective and detects more PAF earlier and more frequently than routine 24-hour Holter recordings. Screening with iECG could be incorporated into routine post-stroke nursing observations to increase diagnosis of PAF, and facilitate institution of guideline-recommended anticoagulation.