http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
엑스선 그레이 스케일 리소그래피를 활용한 반원형 단면의 서브 마이크로 선 패턴의 바이오멤스 플랫폼 응용
김강현 ( Kanghyun Kim ),김종현 ( Jong Hyun Kim ),남효영 ( Hyoryung Nam ),김수현 ( Suhyeon Kim ),임근배 ( Geunbae Lim ) 한국센서학회 2021 센서학회지 Vol.30 No.3
As the rising attention to the medical and healthcare issue, Bio-MEMS (Micro electro mechanical systems) platform such as bio sensor, cell culture system, and microfluidics device has been studied extensively. Bio-MEMS platform mostly has high resolution structure made by biocompatible material such as polydimethylsiloxane (PDMS). In addition, three dimension structure has been applied to the bio-MEMS. Lithography can be used to fabricate complex structure by multiple process, however, non-rectangular cross section can be implemented by introducing optical apparatus to lithography technic. X-ray lithography can be used even for sub-micron scale. Here in, we demonstrated lines with round shape cross section using the tilted gold absorber which was deposited on the oblique structure as the X-ray mask. This structure was used as a mold for PDMS. Molded PDMS was applied to the cell culture platform. Moreover, molded PDMS was bonded to flat PDMS to utilize to the sub-micro channel. This work has potential to the large area bio-MEMS.
파장가변형 레이저 흡수 분광법을 이용한 대기압에서의 N₂O 농도 실시간 측정에 관한 연구
김강현(Kanghyun Kim),박지연(Jiyeon Park),김홍집(Hongjip Kim),이창엽(Changyeop Lee),박대근(Daegeun Park),김대해(Daehae Kim) 한국에너지기후변화학회 2021 한국에너지기후변화학회 학술대회 Vol.2021 No.11
지구온난화를 야기하는 가스 중 이산화탄소(CO₂)를 제외한 가스(Non-CO₂ greenhouse gas)는 메탄(CH₄), 아산화질소(N₂O), 불화 가스 류(PFCs, HFCs, SF6, NF₃) 등이 있다. Non-CO₂ gas의 경우, CO₂보다 실질적인 배출량은 적지만, 지구온난화지수가 높아 지구온난화에 큰 영향을 끼치고 있는 가스들로 저감기술을 통해 오히려 더 큰 효과를 볼 수 있는 가스들이다. N₂O는 지구온난화지수(Global Warming Potential, GWP) 310이며, 국내 온실가스 배출량의 2.6%를 차지하는 가스다. 우리나라 반도체/디스플레이 기술은 세계적으로 인정받고 지속적인 성장세를 이어가고 있지만, 동시에 환경오염 등의 문제점 또한 야기하고 있다. 특히 반도체 산업에서는 N₂O를 증착공정(Deposition process) 등 다양한 공정에서 사용하며, 공정에서 배출되는 가스는 스크러버(Scrubber)를 통해 저감시킨다. 이때 N₂O의 농도를 효과적으로 저감시키기 위해서는 실시간 측정을 통해 스크러버를 제어하는 기술이 필요하다. 파장가변형 레이저 흡수 분광법(Tunable Diode Laser Absorption Spectroscopy, TDLAS)은 실시간으로 정량적인 농도 및 온도 측정이 가능한 비접촉식 측정법으로, 실시간 측정을 통해 스크러버의 성능을 향상시킬 수 있다. 본 연구에서는 상압에서 TDLAS를 이용하여 N₂O를 측정하기 위해, 비교적으로 선강도가 강하고 다른 가스들의 간섭이 없는 중적외선 영역대의 파장 8.31㎛ Laser를 이용하여 실시간으로 측정 및 분석하였다.
KIM, Kanghyun,BU, Youngmin,JEONG, Seungil,LIM, Jongpil,KWON, Youngan,CHA, Dong Seok,KIM, Jinmo,JEON, Sora,EUN, Jaesoon,JEON, Hoon Japan Society for Bioscience, Biotechnology, and A 2006 Bioscience, Biotechnology, and Biochemistry Vol.70 No.8
<P><I>Abies koreana</I> Wilson (<I>A. koreana</I>) is a shrub or broadly pyramidal evergreen tree endemic in the mountainous regions of South Korea. We obtained the essential oil (EO) from alpine needle leaves of <I>A. koreana</I> by the supercritical fluid extraction (SFE) method. EO was analyzed by gas chromatography–mass spectrometry (GC–MS), and 68 compounds were identified constituting 95.66% of the oil. The major components were elemol (11.17%), terpinen-4-ol (9.77%), sabinene (8.86%), 10(15)-cadien-4-ol (7.16%), α-terpineol (6.13%), α-pinene (6.07%) and γ-terpinene (4.71%). To investigate the memory-enhancing effects, we conducted a passive avoidance test using a scopolamine (1 mg/kg, ip)-induced amnesia mouse model. A peritoneal injection of EO from <I>A. koreana</I> (100 mg/kg) showed a memory enhancing effect of 72.7% compared with the control. These results suggest that EO of <I>A. koreana</I> may be a useful therapeutic agent against such amnesia-inducing diseases as Alzheimer and vascular dementia.</P>
Influence of electrical contacts on the 1/<i>f</i> noise in individual multi-walled carbon nanotubes
Kim, Kanghyun,Jang, Doyoung,Lee, Kangho,Kang, Haeyong,Yu, Byung Yong,Lee, Jung Il,Kim, Gyu Tae IOP Pub 2010 Nanotechnology Vol.21 No.33
<P>Low-frequency noise of individual MWNTs was investigated with different metal electrodes. Irrespective of the ohmic or non-ohmic voltage–current characteristics, a strong dependence of the noise on the metal contacts was observed. The good electrical contacts with Pd or Pt electrodes enable a quasi-ballistic transport with a bigger exponent in the relation of <img SRC='http://ej.iop.org/images/0957-4484/21/33/335702/nano353381ieqn1.gif' ALIGN='MIDDLE' ALT='S_I \propto R^{4.8} '/>, similar to 2D metallic film or graphene. On the other hand, the noise in the case of Cr or Ti electrodes is almost linear with the resistance of the nanotubes, which may be an index of the influence of the contacts in the CNTs. </P>