This study was concerned with comparing the measured values of labial alveolar bone through the lateral cephalometric radiography and mandibular incisor cross-sectional tomogram between two groups, one group of mandibular prognathism patients who needed an orthognathic surgery as an experimental group and the other group who had normal molar relationships as a control group. The purpose of the study was to find out the predisposing factors of bone resorption and gingival recession before orthodontic treatment. The results were as follows: 1. The cross-sectional area of labial alveolar bony plate in mandibular prognathism was significantly smaller than that of a control group. 2. In mandibular prognathism, the distance between cementoenamel junction and alveolar crest was significantly greater than control group. 3. There were negative correlations between area of labial alveolar bony plate and distance from cementoenanel junction to alveolar crest, and positive correlations between area of labial alveolar bony plate and distance from alveolar crest to root apex. 4. In mandibular prognathism, there were positive correlations between IMPA and thickness of symphysis, and negative correlations between IMPA and the alveolar bony height. The results of the present study suggested the mandibular prognathism patients were vulnerable to the gingival recession due to the small amount of labial alveolar bone around lower incisors.
임병선,이점숙,조승원,양효식,김명화,곽애경 木浦大學校 沿岸環境硏究所 1995 沿岸環境硏究 Vol.12 No.1
The nutrient removal-capacity of four major dominant species distributed in Namchang-chon polluted with livestock wastewater and Samhyang-chon polluted with industrial and domestic wastewater were investigated. Water qualities and soil properties of three polluted sites were a quite different in concentration of nitrogen, SS and Ga. Dominant species in livestock wasetewater were Persicaria thunbergii, Zizania latiforia, Phragmites communis and Oenanthe japanica, those in industrial and domestic were Phragmites communis. Changes of NO₃-N, NH₄-N and P concentrations of culture solution are high in cultivor of Zizania latiforia and Oenanthe japanica. All four species removed NO₃-N most effectively. In experiment used directely polluted water from three areas ; all species from livestock wasetewater uptaked NO₃-N effectively. Phragmites communis from domestic, and Persicaria thunbergii and Oenanthe japanica from industrial and domestic wasetewater removed NH₄-N effectively. All species cultured in industrial waserewater removed P well, and Phragmites communis and Persicaria thunbergii cultured in domestic wastewater removed it moderately.
22.9㎸ 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석
김점식(Jeom-Sik Kim),김도영(Do-Young Kim),박용범(Yong-Beom Park) 대한전기학회 2010 전기학회논문지 P Vol.59 No.2
The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed 50Ω and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9㎸ distribution line in order to present a new 22.9㎸ distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9㎸ distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.
MATLAB을 이용한 접지저항크기에 따른 유도뢰 차폐효과 분석
김점식(Jeom-Sik Kim),김도영(Do-Young Kim),박용범(Yong-Beom Park),권신원(Sin-Won Kwon),권세원(Se-Won KWonl),임성정(Seong-Jeong Lim) 대한전기학회 2010 대한전기학회 학술대회 논문집 Vol.2010 No.11
본 논문에서는 22.9㎸ 배전가공선로에서 배전선로의 구조에 따른 유도뢰 차폐효과를 알아보고자 한다. 이를 위해 가공지선과 중성선을 겸용하는 선로를 제안하고 가공지선과 중성선이 별도 설비되는 현행선로와 그 결과를 비교한다. 실험을 위하여 수치해석을 통해 유도뢰 차폐효과를 계산하고, MATLAB을 이용하여 모의해석 하였으며, Yokoyama의 논문과 비교하여 그 타당성을 입증하였다. 또한 접지저항이 유도뢰 지폐에 미치는 영향을 알아보기 위하여 집지저항 크기 변화에 따른 유도뢰 차폐효과를 분석하고 접지 개소를 변화시켜 접지저항에 따른 영향을 분석하였다.
축소 모의된 22.9 kV-Y 배전선로의 유도 전압에 대한 신뢰성 검증
김점식 ( Jeom Sik Kim ),최충석 ( Chung Seog Choi ) 한국안전학회(구 한국산업안전학회) 2015 한국안전학회지 Vol.30 No.4
The purpose of this paper is to measure the induced voltage of the downscaled and simulated overhead ground wire of a 22.9kV-Y distribution line. This study performed a test of the downscaled and simulated distribution line according to whether it is grounded or not and the value of the ground resistance. In order to verify the reliability of the data measured by the test, the data was analyzed using the Minitab 17 program. It was found that the induced voltage of the downscaled and simulated distribution line is influenced by the value of the ground resistance. It was also found that the ground resistance obtained at a certain point is closely related to whether electric poles are grounded or not. The analysis results of the measured test data with a statistical method showed that the Anderson Darling (AD) was analyzed to be the smallest as 0.188 when the ground resistance of the electric poles had been maintained at 10Ω. In addition, the P value analyzed to be 0.894 which is in the proximity of the theoretical value of 1 and verified the reliability of the test data. It could be seen that the data measured by the downscaled simulation test forms a linear graph. It is thought that if a distribution line is installed in the same manner as the downscaled, simulated distribution line, the mean induced voltage will be reduced and reliability will be increased.