http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Kosy Jonathan D.,Walmsley Katie,Sharma Akash D.,Gordon Elizabeth A.,Heddon Sadie V.,Anaspure Rahul,Schranz Peter J.,Mandalia Vipul I. 대한슬관절학회 2020 대한슬관절학회지 Vol.32 No.-
Background: Graft malposition is a risk factor for failure of anterior cruciate ligament reconstruction. A 70° arthroscope improves visualisation of the medial wall of the lateral femoral condyle without switching portals. We investigated whether the use of this arthroscope affected the accuracy and precision of femoral tunnel placement. Methods: Fifty consecutive adult patients were recruited. Following one withdrawal and two exclusions, 47 patients (30 in group 1 (70° arthroscope), 17 in group 2 (30° arthroscope)) underwent three-dimensional computed tomography imaging using a grid-based system to measure tunnel position. Results: No difference was found in the accuracy or precision of tunnels (mean position: group 1 = 33.3 ± 6.0% deep–shallow, 27.2 ± 5.2% high–low; group 2 = 31.7 ± 6.9% deep–shallow, 29.0 ± 6.2% high–low; not significant). A post-hoc power analysis suggests a study of 106 patients would be required. Conclusions: This pilot study suggests that tunnel position is not affected by the arthroscope used. An appropriately powered study could investigate this finding alongside other potential benefits of using a 70° arthroscope for this procedure.