RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Stent versus Balloon Dilation for the Treatment of Dominant Strictures in Primary Sclerosing Cholangitis: A Systematic Review and Meta-Analysis

        Marina Tucci Gammaro Baldavira Ferreira,Igor Braga Ribeiro,Diogo Turiani Hourneaux de Moura,Thomas R. McCarty,Alberto Machado da Ponte Neto,Galileu Ferreira Ayala Farias,Antônio Afonso de Miranda Neto 대한소화기내시경학회 2021 Clinical Endoscopy Vol.54 No.6

        Background/Aims: The endoscopic management of primary sclerosing cholangitis (PSC)-associated dominant strictures remainschallenging. This systematic review and meta-analysis aimed to compare balloon dilation and stent placement in the treatment ofdominant strictures among PSC patients. Methods: Literature searches on MEDLINE, EMBASE, Cochrane CENTRAL and Lilacs/Bireme were performed for studiespublished until December 2020. Measured outcomes included clinical efficacy, stricture recurrence, cumulative recurrencefree rate,transplant rate, 5-year survival rate, and adverse events (i.e., pancreatitis, cholangitis, bleeding, perforation and death). Results: A total of 5 studies (n=467) were included. Based on pooled analyses, there were no differences in clinical efficacy (riskdifference [RD], -0.13; 95% confidence interval [CI], -0.58 to 0.33; I2=93%) or transplant rates (RD, -0.09; 95% CI, -0.19 to 0.01;I2=0%); however, the risk of occurrence of adverse events was lower with balloon dilatation than with stent placement (RD,-0.34; 95% CI, -0.45 to -0.23; I2=61%). Among the types of adverse events reported, only the rates of cholangitis/bacteremia weresignificantly lower in balloon dilation patients (RD, -0.19; 95% CI, -0.25 to -0.13; I2=51%). Conclusions: Compared to balloon dilation, stent placement for dominant strictures in PSC appeared to have higher complicationrates without significant differences in efficacy.

      • KCI등재

        Endoscopic Ultrasound Fine-Needle Aspiration versus Fine-Needle Biopsy for Lymph Node Diagnosis: A Large Multicenter Comparative Analysis

        Diogo Turiani Hourneaux de Moura,Thomas R. McCarty,Pichamol Jirapinyo,Igor Braga Ribeiro,Galileu Ferreira Ayala Farias,Marvin Ryou,Linda S. Lee,Christopher C. Thompson 대한소화기내시경학회 2020 Clinical Endoscopy Vol.53 No.5

        Background/Aims: Endoscopic ultrasound fine-needle aspiration (EUS-FNA) is preferred for sampling of lymph nodes (LNs) adjacentto the gastrointestinal wall; however, fine-needle biopsy (FNB) may provide improved diagnostic outcomes. This study aimed toevaluate the comparative effcacy and safety of FNA versus FNB for LN sampling. Methods: This was a multicenter retrospective study of prospectively collected data to evaluate outcomes of EUS-FNA and EUS-FNBfor LN sampling. Characteristics analyzed included sensitivity, specificity, accuracy, the number of needle passes, diagnostic adequacyof rapid on-site evaluation (ROSE), cell-block analysis, and adverse events. Results: A total of 209 patients underwent EUS-guided LN sampling. The mean lesion size was 16.22±8.03 mm, with similar sensitivityand accuracy between FNA and FNB ([67.21% vs. 75.00%, respectively, p=0.216] and [78.80% vs. 83.17%, respectively, p=0.423]). Thespecificity of FNB was better than that of FNA (100.00% vs. 93.62%, p=0.01). The number of passes required for diagnosis was notdifferent. Abdominal and peri-hepatic LN location demonstrated FNB to have a higher sensitivity (81.08% vs. 64.71%, p=0.031 and80.95% vs. 58.33%, p=0.023) and accuracy (88.14% vs. 75.29%, p=0.053 and 88.89% vs. 70.49%, p=0.038), respectively. ROSE was asignificant predictor for accuracy (odds ratio, 5.16; 95% confidence interval, 1.15–23.08; p=0.032). No adverse events were reported ineither cohort. Conclusions: Both EUS-FNA and EUS-FNB are safe for the diagnosis of LNs. EUS-FNB is preferred for abdominal LN sampling. EUS-FNA+ROSE was similar to EUS-FNB alone, showing better diagnosis for EUS-FNB than traditional FNA. While ROSE remained asignificant predictor for accuracy, due to its poor availability in most centers, its use may be limited to cases with previous inconclusivediagnoses.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼