http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Strengthening of concrete structures with buckling braces and buckling restrained braces
Mazloom, Moosa,Pourhaji, Pardis,Farash, Abbas Moosa,Sanati, Amir Hossein Techno-Press 2018 Structural monitoring and maintenance Vol.5 No.3
The purpose of this article is to strengthen concrete structures using buckling and non-buckling braces. Connection plates are modeled in three shapes including the effect of 1.5t hinge zone length, 2t one and without the zone (1.5t-CP, 2t-CP and WCP). According to the verification performed with ABAQUS software, the connection plates which are superior in ductility and strengthening are found. The results show adding steel braces in concrete moment frames increase the strength and stiffness of the structures up to about 12 and 3 times, respectively. The frame strength increased about 21 and 25 percent with considering the effect of 2t hinge length in connection plates compared to 1.5t-CPs and WCPs. Also the ductility of retrofitted frames with 2t-CP improved 2.06 times more than WCP ones. Thus, 2t-CP sample is the best choice for connecting steel braces to concrete moment frames for retrofitting them. Afterwards, optimum conditions for elemental coating in braces with no buckling are assessed. The length of concrete coatings could be reduced about 30 percent, and buckling did not occur. Therefore, the weight of restraining coating decreased, and its performance improved. It is worth noting that BRBs could be constructed with only steel materials, which have outer steel tubes too. In fact, only the square cross sections of the tube profiles are appropriate for removing the filler concrete, and the rectangular ones are prone to buckle around their weak axis.
Chaudhry, Shehzad Ashraf,Naqvi, Husnain,Shon, Taeshik,Sher, Muhammad,Farash, Mohammad Sabzinejad Springer-Verlag 2015 JOURNAL OF MEDICAL SYSTEMS Vol.39 No.6
<P>Telecare medical information systems (TMIS) provides rapid and convenient health care services remotely. Efficient authentication is a prerequisite to guarantee the security and privacy of patients in TMIS. Authentication is used to verify the legality of the patients and TMIS server during remote access. Very recently Islam et al. (J. Med. Syst. 38(10):135, 2014) proposed a two factor authentication protocol for TMIS using elliptic curve cryptography (ECC) to improve Xu et al.'s (J. Med. Syst. 38(1):9994, 2014) protocol. They claimed their improved protocol to be efficient and provides all security requirements. However our analysis reveals that Islam et al.'s protocol suffers from user impersonation and server impersonation attacks. Furthermore we proposed an enhanced protocol. The proposed protocol while delivering all the virtues of Islam et al.'s protocol resists all known attacks.</P>