http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Tan, Fa-Bing,Wang, Chao,Dai, Hong-Wei,Fan, Yu-Bo,Song, Jin-Lin The Korean Academy of Prosthodonitics 2018 The Journal of Advanced Prosthodontics Vol.10 No.1
PURPOSE. The study aimed to identify the accuracy and reproducibility of preparations made by gypsum materials of various colors using quantitative and semi-quantitative three-dimensional (3D) approach. MATERIALS AND METHODS. A titanium maxillary first molar preparation was created as reference dataset (REF). Silicone impressions were duplicated from REF and randomized into 6 groups (n=8). Gypsum preparations were formed and grouped according to the color of gypsum materials, and light-scanned to obtain prepared datasets (PRE). Then, in terms of accuracy, PRE were superimposed on REF using the best-fit-algorithm and PRE underwent intragroup pairwise best-fit alignment for assessing reproducibility. Root mean square deviation (RMSD) and degrees of similarity (DS) were computed and analyzed with SPSS 20.0 statistical software (${\alpha}=.05$). RESULTS. In terms of accuracy, PREs in 3D directions were increased in the 6 color groups (from 19.38 to $20.88{\mu}m$), of which the marginal and internal variations ranged $51.36-58.26{\mu}m$ and $18.33-20.04{\mu}m$, respectively. On the other hand, RMSD value and DS-scores did not show significant differences among groups. Regarding reproducibility, both RMSD and DS-scores showed statistically significant differences among groups, while RMSD values of the 6 color groups were less than $5{\mu}m$, of which blue color group was the smallest ($3.27{\pm}0.24{\mu}m$) and white color group was the largest ($4.24{\pm}0.36{\mu}m$). These results were consistent with the DS data. CONCLUSION. The 3D volume of the PREs was predisposed towards an increase during digitalization, which was unaffected by gypsum color. Furthermore, the reproducibility of digitalizing scanning differed negligibly among different gypsum colors, especially in comparison to clinically observed discrepancies.
Fa-YanMeng,Bing-Li Jiang,Cui-Wu Lin,Li Wang,Xiao-He Tan 대한화학회 2011 Bulletin of the Korean Chemical Society Vol.32 No.3
Two new benzimidazolyl-containing complexes have been synthesized by reactions of Cu^II salts and 1,2-bis(benzimidazolyl)benzene (H_2bbbz) with two different dicarboxylate ligands.When phthalate acid (H2pt) was employed as secondary ligand, a 0Dmolecular complex Cu(H_2bbbz)(pt)·(H_2pt) (1)was furnished and when the secondary ligand was instead by a linear bridging ligand of terephthalic acid (H_2tp) a 1D zipper-like coordination polymer [Cu(H_2bbbz)(tp)·2(C_2H_5OH)·H_2O]n (2) was obtained, suggesting the structure-direction effect of the secondary dicarbxylate ligand. The preliminary investigation on the spectral properties of the complexes was also presented.
Meng, Fa-Yan,Jiang, Bing-Li,Lin, Cui-Wu,Wang, Li,Tan, Xiao-He Korean Chemical Society 2011 Bulletin of the Korean Chemical Society Vol.32 No.3
Two new benzimidazolyl-containing complexes have been synthesized by reactions of $Cu^{II}$ salts and 1,2-bis(benzimidazolyl) benzene ($H_2bbbz$) with two different dicarboxylate ligands. When phthalate acid ($H_2pt$) was employed as secondary ligand, a 0D molecular complex Cu$(H_2bbbz)(pt){\cdot}(H_2pt)$ (1)was furnished and when the secondary ligand was instead by a linear bridging ligand of terephthalic acid ($H_2tp$) a 1D zipper-like coordination polymer $[Cu(H_2bbbz)(tp){\cdot}2(C_2H_5OH){\cdot}H_2O]_n$ (2) was obtained, suggesting the structure-direction effect of the secondary dicarbxylate ligand. The preliminary investigation on the spectral properties of the complexes was also presented.
Na Yu,Hong-Wei Dai,Fa-Bing Tan,Jin-Lin Song,Chao-Yi Ma,Xue-Lu Tong 대한치과보철학회 2021 The Journal of Advanced Prosthodontics Vol.13 No.5
PURPOSE. To evaluate the impact of five different tooth preparation designs on the marginal and internal fit discrepancies of cobalt-chromium (CoCr) crowns produced by computer-aided designing (CAD) and selective laser melting (SLM) processes. MATERIALS AND METHODS. Five preparation data were constructed, after which design crowns were obtained. Actual crowns were fabricated using an SLM process. After the data of actual crowns were obtained with structural light scanning, intaglio surfaces of the design crown and actual crown were virtually superimposed on the preparation. The fit-discrepancies were displayed with colors, while the root means square was calculated and analyzed with one-way analysis of variance (ANOVA), Tukey’s test or Kruskal-Wallis test (α = .05). RESULTS. The marginal or internal color-coded images in the five design groups were not identical. The shoulder-lip and sharp line angle groups in the CAD or SLM process had larger marginal or internal fit discrepancies compared to other groups (P < .05). In the CAD process, the mean marginal and internal fit discrepancies were 10.0 to 24.2 μm and 29.6 to 31.4 μm, respectively. After the CAD and SLM processes, the mean marginal and internal fit discrepancies were 18.4 to 40.9 μm and 39.1 to 47.1 μm, respectively. The SLM process itself resulted in a positive increase of the marginal (6.0 - 16.7 μm) and internal (9.0 - 15.7 μm) fit discrepancies. CONCLUSION. The CAD and SLM processes affected the fit of CoCr crowns and varied based on the preparation designs. Typically, the shoulder-lip and sharp line angle designs had a more significant effect on crown fit. However, the differences between the design groups were relatively small, especially when compared to fit discrepancies observed clinically.