RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        Evaluation of the Protective Effect of an Ophthalmic Viscosurgical Device on the Ocular Surface in Dry Eye Patients during Cataract Surgery

        Do Yeh Yoon,Joo Hyun Kim,Hyun Sun Jeon,Hee Eun Jeon,Sang Beom Han,Joon Young Hyon 대한안과학회 2019 Korean Journal of Ophthalmology Vol.33 No.5

        Purpose: To evaluate the protective effect of applying an ophthalmic viscosurgical device (OVD) to the ocular surface during cataract surgery and its ability to prevent dry eye syndrome. Methods: Twenty-four patients aged 50 to 75 years who underwent cataract surgery at Seoul National University Bundang Hospital and agreed to participate in the study were included and divided into two groups: a study group who underwent cataract surgery after application of an OVD to the ocular surface, and a control group who underwent cataract surgery without application of an OVD. DisCoVisc was used as the OVD in the study group, while other factors including surgical techniques and administration of anesthetic agents were performed in both groups in the same manner. Indicators of dry eye syndrome including ocular staining score, tear break-up time, and tear osmolality were analyzed. Ocular surface disease index and a visual analog scale were analyzed for dry eye symptoms, and the amount of balanced salt solution used during surface irrigation and operation time were also analyzed. Results: Significant improvement in the tear break-up time, corneal ocular staining score, and ocular surface disease index score in the study group compared with the control group one week after operation (by the Mann-Whitney test). Use of OVD was associated with longer operating time. Conclusions: OVD applied to the ocular surface during cataract surgery had a protective effect on the ocular surface one week after surgery.

      • KCI등재

        Comparison of Ocular Biometry and Refractive Outcomes Using IOL Master 500, IOL Master 700, and Lenstar LS900

        Jae Shin Song,Do Yeh Yoon,Joon Young Hyon,Hyun Sun Jeon 대한안과학회 2020 Korean Journal of Ophthalmology Vol.34 No.2

        Purpose: To evaluate the agreement in ocular biometry outcomes measured by three different devices, the IOL Master 500, IOL Master 700, and Lenstar LS900, and compare the refractive outcomes after cataract surgery obtained using those three devices. Methods: Medical records of 178 eyes of 89 patients who underwent ocular biometry with the three devices were retrospectively reviewed, and 124 eyes met the inclusion criteria. Paired comparisons were performed for axial length (AL), mean keratometry (Km), and anterior chamber depth and quantified their agreement using Bland-Altman plots. Subgroup analyses were done according to the AL and the Km. Refractive outcomes were compared with respect to absolute prediction errors after cataract surgery in 54 eyes. Results: Among 124 eyes, 12, 3, and 5 eyes failed to be measured of AL by IOL Master 500, IOL Master 700 and Lenstar LS900, respectively. The AL measured by Lenstar LS900 was longer than that measured by IOL Master 500 and IOL Master 700 (p < 0.001, p = 0.002, respectively). Subgroup analysis revealed that these results were statistically significant only in long eyes (AL >25.5 mm). Km measured using the IOL Master 500 was steeper than that measured with the IOL Master 700 or Lenstar LS900 (p = 0.001, p < 0.001, respectively). anterior chamber depth measured by IOL Master 500 was shallower than that measured by IOL Master 700 or Lenstar LS900 (p < 0.001, p < 0.001, respectively). Ocular biometry measurements by the three devices showed high agreement with narrow 95% limits of agreement. Absolute prediction errors from the 3 devices showed no statistically significant differences after cataract surgery. Conclusions: The IOL Master 700 and Lenstar LS900 demonstrated superior acquisition rates of biometric measurements compared with the IOL Master 500. Ocular biometry using the 3 different devices showed high agreement, although statistically significant differences were observed; however, since there was no difference in predicting the refractive outcomes, those differences are clinically negligible.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼