        Identifying SDC-Causing Instructions Based on Random Forests Algorithm

        ( Liping Liu ),( Linlin Ci ),( Wei Liu ),( Hui Yang ) 한국인터넷정보학회 2019 KSII Transactions on Internet and Information Syst Vol.13 No.3

        Silent Data Corruptions (SDCs) is a serious reliability issue in many domains of computer system. The identification and protection of the program instructions that cause SDCs is one of the research hotspots in computer reliability field at present. A lot of solutions have already been proposed to solve this problem. However, many of them are hard to be applied widely due to time-consuming and expensive costs. This paper proposes an intelligent approach named SDCPredictor to identify the instructions that cause SDCs. SDCPredictor identifies SDC-causing Instructions depending on analyzing the static and dynamic features of instructions rather than fault injections. The experimental results demonstrate that SDCPredictor is highly accurate in predicting the SDCs proneness. It can achieve higher fault coverage than previous similar techniques in a moderate time cost.

      • KCI등재

        Control Flow Checking at Virtual Edges

        ( Liping Liu ),( Linlin Ci ),( Wei Liu ),( Hui Yang ) 한국인터넷정보학회 2017 KSII Transactions on Internet and Information Syst Vol.11 No.1

        Dynamically checking the integrity of software at run-time is always a hot and difficult spot for trusted computing. Control-flow integrity is a basic and important safety property of software integrity. Many classic and emerging security attacks who introduce illegal control-flow to applications can cause unpredictable behaviors of computer-based systems. In this paper, we present a software-based approach to checking violation of control flow integrity at run-time. This paper proposes a high-performance and low-overhead software control flow checking solution, control flow checking at virtual edges (CFCVE). CFCVE assigns a unique signature to each basic block and then inserts a virtual vertex into each edge at compile time. This together with insertion of signature updating instructions and checking instructions into corresponding vertexes and virtual vertexes. Control flow faults can be detected by comparing the run-time signature with the saved one at compile time. Our experimental results show that CFCVE incurs only 10.61% performance overhead on average for several C benchmark programs and the average undetected error rate is only 9.29%. Compared with previous techniques, CFCVE has the characteristics of both high fault coverage and low memory and performance overhead.

      • KCI등재

        Optimisation of Readout Performance of Phase-Change Probe Memory in Terms of Capping Layer and Probe Tip

        Lei Wang,C. David Wright,Mustafa. M. Aziz,Ci Hui Yang,Guo Wei Yang 대한금속·재료학회 2014 ELECTRONIC MATERIALS LETTERS Vol.10 No.6

        The capping layer and the probe tip that serve as the protective layer and the recording tool, respectively, for phase-change probe memory play an important role on the writing performance of phase-change probe memory, thus receiving considerable attention. On the other hand, their influence on the readout performance of phasechange probe memory has rarely been reported before. A three-dimensional parametric study based on the Laplace equation was therefore conducted to investigate the effect of the capping layer and the probe tip on the resulting reading contrast for the two cases of reading a crystalline bit from an amorphous matrix and reading an amorphous bit from a crystalline matrix. The results indicated that a capping layer with a thickness of 2 nm and an electrical conductivity of 50 Ω−1m−1 is able to provide an appropriate reading contrast for both the cases, while satisfying the previous writing requirement, particularly with the assistance of a platinum silicide probe tip.