Francesca De Cagna,Laura Fusar-Poli,Stefano Damiani,Matteo Rocchetti,Gianluca Giovanna,Alessia Mori,Pierluigi Politi,Natascia Brondino 대한정신약물학회 2019 CLINICAL PSYCHOPHARMACOLOGY AND NEUROSCIENCE Vol.17 No.1
Several studies have demonstrated the neuromodulating function of oxytocin (OT) in response to anxiogenic stimuli as well as its potential role in the pathogenesis of depression. Consequently, intranasal OT (IN-OT) has been proposed as a potential treatment of anxiety and depressive disorders. The present systematic review aimed to summarize the randomized controlled trials (RCTs) evaluating the effect of IN-OT on anxiety and depressive symptoms. Overall, 15 studies were included, involving patients with social anxiety disorders (7 studies), arachnophobia (1), major depression (3) or post-natal depression (4), and mainly evaluating single-dose administrations of IN-OT. Results showed no significant effects on core symptomatology. Five crossover studies included functional magnetic resonance imaging investigation: one trial showed reduced amygdala hyper-reactivity after IN-OT in subjects with anxiety, while another one showed enhanced connectivity between amygdala and bilateral insula and middle cingulate gyrus after IN-OT in patients but not in healthy controls. More studies are needed to confirm these results. In conclusion, up to date, evidence regarding the potential utility of IN-OT in treating anxiety and depression is still inconclusive. Further RCTs with larger samples and long-term administration of IN-OT are needed to better elucidate its potential efficacy alone or in association with standard care.
Accuracy and reliability of stitched cone-beam computed tomography images
Egbert, Nicholas,Cagna, David R.,Ahuja, Swati,Wicks, Russell A. Korean Academy of Oral and Maxillofacial Radiology 2015 Imaging Science in Dentistry Vol.45 No.1
Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.
Accuracy and reliability of stitched cone-beam computed tomography images
Nicholas Egbert,David R. Cagna,Swati Ahuja,Russell A. Wicks 대한영상치의학회 2015 Imaging Science in Dentistry Vol.45 No.1
Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer’s imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.