http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
연료분무 및 연소 1 : 밸브리프트 변화에 따른 연소실내 흡기유동 및 연료분포에 대한 수치 해석적 연구
전영수 ( Y S Jeon ),송미지 ( M J Song ),이성욱 ( S W Lee ),김경배 ( K B Kim ) 한국액체미립화학회 2013 한국액체미립화학회 학술강연회 논문집 Vol.2013 No.-
While variable valve actuation or variable valve lift (VVL) is used increasingly in spark ignition (SI) engines to improve the volumetric efficiency or to reduce the pumping losses, it is necessary to understand the impact of variable valve lift and timing on the in-cylinder gas motions and mixing processes. In this paper, characteristics of the in-cylinder flow and fuel distribution for various valve lifts(4, 6, 8, 10mm) were simulated in a GDI engine. It is expected that the investigation will be helpful in understanding and improving GDI combustion when a VVL system is used. The CFD results showed that a increased valve lift could significantly enhance the mixture and in-cylinder tumble motion because of the accelerated air flow. Also, it can be found that the fuel distribution is more affected by earlier injection (during intake process) than that of later injection (end of compression). These may contribute to an improvement in the air-fuel mixing but also to an optimization of intake and exhaust system.
EMTDC를 이용한 D-STATCOM의 전압제어 효과분석
전영수(Y.S. Jeon),박상호(S.H. Park),김수열(S.Y. Kim),이재욱(J.W. Lee),곽노홍(N.H. Kwak),추진부(J.B Choo) 전력전자학회 2004 전력전자학술대회 논문집 Vol.- No.-
고도화 정보화시대의 도래로 수용가측의 전력품질에 대한 관심이 나날이 높아지고 있고, 전원 품질에 의한 경제적 피해가 늘어나면서 중요 부하 및 계통을 보호하기 위한 전력품질 보상기기 개발에 대한 연구가 활발히 진행되고 있다. 대표적인 전력품질 향상기기로는 D-STATCOM, DVR, SSTS 등이 있다.
김수열(S.Y Kim),윤종수(J.S Yoon),장병훈(B.H Chang),전영수(Y.S Jeon),백두현(D.H Baek),이세일(S.I. Lee) 전력전자학회 2005 전력전자학술대회 논문집 Vol.- No.-
한국전력공사에서는 전압원 인버터형 FACTS 기기인 UPFC를 전남 강진군 강진변전소에 설치(2003. 5. 23준공) 운전하였다. 강진 UPFC는 한전과 (주)효성이 공동으로 투자하고, 지멘스와의 기술제휴를 통해 개발하였으며, 40MVA 병렬인버터, 40MVA 직렬인버터로 구성되어 총 80MVA 용량이다. 준공이후 2년여에 걸친 운전으로, 강진 UPFC의 고장정지는 현저히 줄었다. 본 논문에서는 강진 UPFC의 주요 이벤트, 고장해소 및 설비의 신뢰성 향상을 위한 대응 조치들에 대해 정리하였다.
A Study on the Application of the DVR System using EMTDC Simulation
최영도(Y. D. Choy),곽노홍(N. H. Kwak),전영수(Y. S. Jeon),전동훈(D. H. Jeon) 전력전자학회 2008 전력전자학술대회 논문집 Vol.- No.-
Recently, the interest on power quality has been hot issue because the equipments cause voltage disturbance and become more sensitive to the voltage disturbance. The DVR(Dynamic Voltage Restorer) is one of the Custom Power Device that can compensate the voltage. DVR operates as a series connected compensator whose output voltage can be controlled system voltage. And the magnitude of compensation voltage is limited by the characteristics of system and load. Compensation capability of DVR was simulated by EMTDC under several condition. This paper analyzed effect of DVR's compensation at power quality test center which has SSFG(Sag, swell, and Flicker Generator, CPDs(SSTS, DVR, DSTATCOM), and loads.
김수열(S.Y. Kim),이원교(W.K. Lee),장병훈(B.H. Chang),전영수(Y.S. Jeon),이세일(S.I. Lee),배정현(J.H. Bae) 전력전자학회 2006 전력전자학술대회 논문집 Vol.- No.-
한전 전력연구원은 1990년대부터 FACTS(유연송전시스템 : Flexible AC Transmission System)을 연구해 온 이래 80MVA UPFC(종합조류제어기 : Unified Power Flow Controller)를 2003. 5월 신강진전력소관내 강진변전소에 준공하였다. 효성과 지멘스의 기술제휴를 통해 개발된 강진변전소 UPFC를 통해 FACTS 엔지니어링, 제어 알고리즘 및 유지보수 기술이 확보되었다. 초창기 안정화운전 기간동안 제어핵심기술과 일부예비품의 미확보가 가용율(Availability)에 큰 영향을 미쳤으나, 현재 강진 UPFC는 안정적으로 운전되고 있다. 본 논문에서는 그 동안의 강진 UPFC의 고장내용을 종합분석하고, 가용율을 정리하였다