게이트 99mTc - MIBI 심근 SPECT의 심근 분절 운동 평가능력
이동수(D . S . Lee),정준기(J . K . Chung),이명철(M . C . Lee),김선욱(S . W . Kim),김상현(S . H . Kim),현인영(I . Y . Hyun),이명묵(M . M . Lee),고창순(C . S. Koh) 대한핵의학회 1995 핵의학 분자영상 Vol.29 No.4
N/A Information about regional wall motion obtained with gated Tc-99m-MIBI SPECT was compared in 23 subjects(4 normals) to echocardiography or contrast left ventriculography. Gated SPECT study using 20-30 mCi Tc-99m-MIBI were aquired for 8 frames/RR interval (aqusition time=40min.) and processed with Cine Mode computer protocol. Regional wall motion was assessed by visual analysis. The concordance with echocardiography was 88% and with contrast ventriculography was 78%. We conclude that gated Tc-99m-MIBI SPECT was effective in assessing the regional wall motion with the information of regional perfusion in one study.