http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
성병호(Byung-Ho Sung),최지훈(Jee-Hoon Choi),유성렬(Seong-Ryul Ryu),김철주(Chul-Ju Kim) 대한설비공학회 2006 대한설비공학회 학술발표대회논문집 Vol.2006 No.11
The present study was conducted to test whether a secondary wick could keep the liquid flow from vapor intrusion into the liquid line, resulting the failure of liquid flow into the evaporator when it occurred the liquid compensator dry out for an LHP without a secondary wick. Experimentally it was seen that a secondary wick could resolve the operational failure due to the liquid chamber dry out within the limit of its maximum capillary pressure. Calculating the allowable temperature rise of the liquid compensator wall above the liquid line temperature showed that it decreased exponentially with liquid line temperature, ranging from 19 ℃ to 4 ℃ when the liquid temperature increased from 20 ℃ to 60℃.