RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • DAF 내의 마이크로버블 확산에 관한 실험적 연구

        오신일(Shin-Il Oh),박상희(Sang-Hee Park),오용훈(Yong-Hoon Oh) 대한설비공학회 2015 대한설비공학회 학술발표대회논문집 Vol.2015 No.11

        The purpose of this study is to investigate the diffusion range of micro-bubble in DAF and the generation of micro-bubble in Orifice nozzle. To investigate the diffusion range of bubbles in DAF and the generation of micro-bubble by the orifice nozzle, the orifice nozzle diameter( =2∼7mm) and heigh of Baffle(h)/Water Level(H) h/H=0.82, 0.875, 0.93 were changed. The total flow rate flowing into the system showed an increased sharply as increasing of orifice nozzle diameter. But the recycle flow rate and the air inlet flow rate showed a decreased as increasing of nozzle diameter. Changing the nozzle diameter and the baffle height visualized the diffusion range of micro-bubble in a DAF. The diffusion range of micro-bubbles at Separation zone showed an increased as increasing of orificeOrifi nozzle diameter and as decreasing of h/H. Also, the Stratified flow and White water blanket at Separation zone were formed at over nozzle diameter 4mm.

      • KCI등재

        재순환 유동 공기 자가흡입에 의한 마이크로버블 발생 오리피스 노즐 시스템에 대한 실험적 연구

        오신일(Shin-il Oh),박상희(Sang-Hee Park) 한국기계가공학회 2018 한국기계가공학회지 Vol.17 No.1

        An experimental study was performed on the orifice nozzle system that generates micro-bubbles by air self-suction using a venturi nozzle. This study experimentally investigates the amount of air sucked into the venturi nozzle and the number of micro-bubbles generated by the orifice nozzle system in Cases 1 and 2. The experimental conditions were varied by changing the diameter of the orifice nozzle (d=2∼7 ㎜) and the number of holes of the perforated plate nozzle (n = 2-12). In Case 1, the air self-suction was more than 2 LPM at d ≤ 4 ㎜. When d = 4 ㎜, the total number of bubbles was 29,777, and it was confirmed that micro-bubbles occupied approximately 65% of the total number of bubbles. In Case 2, the air self-suction was maintained constant at approximately 2.5 LPM regardless of the number (n) of holes. The total amount of bubbles increased when n increased but remained constant at approximately 44,000 when n ≥ 7 EA. It was also confirmed that more than 80% of all bubbles were micro-bubbles when n ≥ 10 EA. Thus, the number of micro-bubbles increased by approximately 15% compared to the experimental result of Case 1, which was optimized with d = 4 ㎜.

      • 파형판 열교환기를 이용한 백연저감 시스템에 대한 실험적 연구

        오용훈(Yong-Hoon Oh),박상희(Sang-Hee Park),오신일(Shin-Il Oh),조길환(Gil-Hwan Cho) 대한설비공학회 2015 대한설비공학회 학술발표대회논문집 Vol.2015 No.11

        This experiment was a study of white plume reduction in range of a high temperature. To investigate the white plume reduction in system, the exhaust air velocity(2, 3, 4m/s), the outdoor air intake velocity(0.5, 1, 1.5m/s) and the water velocity(0.2, 0.4, 0.6m/s) were changed. The system is composed of corrugated plate heat exchanger, Air to Air heat exchanger, Air to Water heat exchanger and mixing chamber. White plume effect was better depending on system operation condition. At whole experimental results, even if temperature and humidity exist under saturation line has occurred the white plume when difference in air temperature between outdoor air is great. But it is showed that white plume is happening in no less than 35℃. Reduction effect of white plume showed that appeared in sequence of case 1, 2, 3, 4 according to the system operating conditions.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼