이상국(S. G. Lee),박중혁(J. H Park),Y. B. Kim 한국동력기계공학회 2006 한국동력기계공학회 학술대회 논문집 Vol.- No.-
The purpose of this study is to verify availability of the acoustic emission in-situ diagnosis method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized high temperature steam flowed through gate valve(1st stage reheater valve) and glove valve/main steam dump valve) on the normal size of 4 and 8". The valve internal leak diagnosis system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, signal level analysis and RMS(root mean square) analysis of acoustic signal emitted from the valve operating condition internal leak.