http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
박동관,장익태,Park, Dong-Kwan,Chang, Ik-Tai 대한치과보철학회 1986 대한치과보철학회지 Vol.24 No.1
An in vitro study was performed to evaluate adaptation of custom direct, custom indirect, and prefabricated post system on 15 extracted upper central incisors. 15 specimens were prepared and equally devided into 3 groups under random sampling. Each group of 5 cast posts was made with custom direct, custom indirect, and prefabricated post core method. Gap between inner wall of the dentin and outer wall of the cast post was measured on electron microphotographic prints at x500 magnification. The result were as follows ; 1. No significant difference of adaptation at cervical portion was found between each method. 2. Prefabricated post core method had poor adaptation compared with other methods. 3. Even distribution of adaptation was found in custom direct method between each portion. 4. Prefabricated post core method showed remarkable difference in adaptation between each portion.
Holographic interferometry를 이용한 열중합 애크릴릭 레진의 변형에 관한 연구
박동관,장익태,김광남,Park, Dong-Kwan,Chang, Ik-Tae,Kim, Kwang-Nam 대한치과보철학회 1995 대한치과보철학회지 Vol.33 No.1
Since heat curing acrylic resins undergo unavoidable dimensional changes following polymerization, adaptation can be altered. Until recently, although numerous studies on the dimensional changes of denture base were based on a microscopic technic that measures the relative displacement of a limited reference points on the denture base, but there have been few studies on the distortions of resins using holographic interferometry. Purpose of this study was to determine and compare the dimensional changes and fringe patterns of 4 heat curing acrylic resins, and observe the distortions of acrylic resin denture base by temperature change with the aid of the holographic interferometry. Holographic interferograms were taken on the resin specimens and acrylic resin denture base with the 10mW He-Ne laser and double exposure method. Comparison and analysis of fringe pattern on the recorded object surface was performed. The following results were obtained. 1. The dimensional changes for the high impact resin Lucitone 199 were statistically the greatest of all resins, and the rapid heat curing resin Premium super 20 were the least. 2. The most polymerization shrinkage of all materials occured in initial period of measurements, at this time the difference of polymerization shrinkage properties between resins was founded. 3. The stress distribution of specimens was seen by various type of fringe pattern which had directionality. 4. The polymerization shrinkage of resins was greatly influenced by temperature change. 5. The partial deformations of resin denture base were observed in 70 C and 90 C water.