RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        자외선/H<sub>2</sub>O<sub>2</sub> 처리시 남조류 기인 유기물 특성이 수산화 라디칼 반응성 및 운전조건에 미치는 영향

        남숙현 ( Sookhyun Nam ),이주원 ( Juwon Lee ),김은주 ( Eunju Kim ),황태문 ( Tae-mun Hwang ) 한국수처리학회 2020 한국수처리학회지 Vol.28 No.4

        This study interrogates the influence of algal organic matter on hydroxyl radial (ㆍOH) scavenging factors. The ㆍOH scavenging factor represents the rate at which ㆍOH is scavenged by background substances in aqueous solutions, which is key to the design and operation of UV/H<sub>2</sub>O<sub>2</sub> processes for water treatment. Extracellular organic matter (EOM) and intracellular organic matter (IOM) were extracted from cyanobacteria acquired from lake water. Synthetic water was manufactured by using either EOM or IOM, and the resulting hydroxyl radical scavenging factors were measured and compared. The organic properties of the EOM and IOM were analyzed by using liquid chromatography organic carbon detection (LC-OCD) and fluorescence excitation-emission matrices (F-FEM). Analyses revealed that EOM samples exhibited strong peaks associated with tryptophan-like, fulvic-like, and humic-like (excitation/emission 250-260/380-480) substances. By comparison, the tryptophan-like peak was dominant in IOM samples. Six components were observed in LC-OCD chromatograms, with neutrals being the highest component of both of EOM and IOM, yet EOM also had high humics and LMW acids. This study proposes a predictive model that estimates the optimal UV and H2O2 doses necessary to maximize the removal of target compounds. Removal of 90% of the target compound (D90) required 6.8 mg/L of hydrogen peroxide at 1200 mJ/㎠. When comparing theoretical prediction with experimental values, the difference in the elimination rate was less than 10%.

      • UV 소독에서 E.coli 모니터링을 위한 ATP 적용

        남숙현 ( Nam Sookhyun ),이주원 ( Lee Joowon ),구재욱 ( Koo Jae-wuk ),김은주 ( Kim Eunju ),황태문 ( Hwang Tae-mun ) 한국물환경학회 2020 한국물환경학회·대한상하수도학회 공동 춘계학술발표회 Vol.2020 No.-

        먹는물의 미생물 감시를 위해 현재 사용되고 있는 표준 방법(Heterotrophic plate counts, HPC)은 배양을 기본으로 하여 많은 시간과 노력이 필요하며, 1~2일이 지나야 결과를 확인할 수 있다. 이는 결과가 나오기 전에 미생물에 오염된 물을 먹을 수도 있다. 따라서 최근에는 미생물을 신속하게 측정 가능한 방법들이 개발되고 있으며, 그 중 하나가 ATP(Total adenosine triphosphate) 측정방법이다. ATP 장점은 분석 시간이 짧아 결과를 수분 내에 얻을 수 있다는 것이다. ATP는 DNA(Deoxyribo-nucleic acid)과 같은 모든 살아있는 유기체의 특징이다. 세포 용해를 통해 세포에서 ATP를 추출한 후, 루시퍼라아제 효소 및 그 기질인 루시페린으로 어세이(Assay)해서, 생물발광 양을 측정한다. ATP 검출은 생명공학적인 방법에 의해 생성된 효소를 이용한 효소 측정을 포함한다. 미생물 활성의 정확한 측정을 위해서는 세포 내(Intra-cellular) ATP와 세포 외(Extra-cellular) 세포 사이의 차이가 필요하며, ATP 측정법은 이 두 가지가 가능하다. 본 연구에서는 E.coli를 대상으로 UV 소독시 불활성화된 E.coli 개체수를 분석하기 위해 ATP 측정법을 적용해보았다. 본 연구에서 E.coli(ATCC 15597)를 사용하였다. 실험에 사용한 자외선 장치는 실험실 규모의 Collimated Beam (저압수은램프, 11 W, Philips Co., Netherlands)으로 파장은 253.7 nm이다. 자외선 조사시 시료는 유리 페트리디쉬에 담아 사용했으며, 자외선 광량(mW/㎠)은 UVX Radiometer(UV254 detector, UVP Co., USA)로 측정하였다. 빛이 수직으로 내려오게 조절하였고, 마그네틱 바를 사용하여 교반하였다. 반응기와 램프 사이의 거리는 5 ㎝로 조정하였다. E.coli 개체수는 HPC로 하였다. ATP는 Clean-TraceTM ATP test(3M, USA)로 측정하여 비교하였다. E.coli 초기농도는 1.2×105 CFU/mL로 하였다. 온도 25 ℃, pH 7.0 조건에서 테스트하였다. ATP 측정방법으로 미생물 불활성도(Inactivation)를 테스트하였다. E.coli를 대상으로 자외선 조사시 E.coli 불활성화를 HPC 방법와 ATP 방법으로 비교 분석한 결과 자외선 강도를 4 mJ/㎠, 6 mJ/㎠, 23 mJ/㎠ 및 34 mJ/㎠로 증가시킴에 따라 E.coli 개체수는 5 log까지 감소하였으나, ATP는 명확하게 감소되는 결과를 나타내지 못하는 것으로 나타났다.

      • 자외선/염소 및 자외선/H<sub>2</sub>O<sub>2</sub>에서 Microcystin-LR 제거 특성

        남숙현 ( Nam Sookhyun ),이주원 ( Lee Joowon ),구재욱 ( Koo Jae-wuk ),김은주 ( Kim Eunju ),황태문 ( Hwang Tae-mun ) 한국물환경학회 2020 한국물환경학회·대한상하수도학회 공동 춘계학술발표회 Vol.2020 No.-

        조류 및 조류독소물질은 수처리 공정운영에서 웨어(Weir)의 오염, 유입스크린의 폐색, 조류매트의 생산, 플럭(Floc)의 침전방해, EOM(Extracellular organic matter)또는 조류에 의한 필터의 폐색, 염소요구량 증가, 응집제 요구량 증가, pH의 변화, 소독부산물의 증가, 맛, 냄새 물질과 남조독성물질의 방출 등 다양한 문제를 발생시킨다. 이러한 조류 독소를 제거하기 위해서는 보다 효과적인 기술이 필요하며, 그 가운데 자외선을 활용한 고도산화공정(Advanced oxidation process, AOP)이 고려되고 있다. 본 연구에서는 국내 정수장의 실제 처리수에 자외선/염소 및 자외선/H<sub>2</sub>O<sub>2</sub>를 적용하여 사용되는 Microcystin-LR(MC-LR)의 제거특성을 상호 비교하였다. 시료는 국내 N 정수장 모래여과수를 대상으로 하였으며, MC-LR(Cfm Oskar Tropitzsch GmbH, Germany)은 100 ㎍/L로 제조하여 사용하였다. 염소는 5 % 차아염소산나트륨(Sigma-Aldrich, USA)으로, 1000 ㎎/L으로 제조하여 사용하였다. pH 조정은 Buffer 용액(Sigma-Aldrich, USA)으로 조정하였다. 본 연구에 사용한 실험실 규모의 자외선 조사장치(Collimated Beam)를 나타낸 것이다. 자외선 램프는 저압수은램프(11 W, Philips co., Netherlands, 253.7 ㎚)를 사용하였다. 자외선 조사시 시료는 유리 페트리디쉬(Petri-dish)에 담아 사용했다. 시료에 pH를 조정하여 MC-LR 표준시약을 100 ㎍/L 농도로 주입하였다. 자외선/염소와 자외선/H<sub>2</sub>O<sub>2</sub>에는 자외선 조사량 0, 200, 400, 600 및 800 mJ/㎠에 염소 및 과산화수소 농도를 0.3, 0.6, 0.9, 1.2 ㎎/L로 주입하여 비교 분석하였다. MC-LR의 농도는 액체크로마토그래프(Surveyor, Thermo, USA)로 측정하였다. 검출기는 PDA 238 ㎚를 사용하였으며, 칼럼은 ZORBAX Extend-C18 4.6×150 ㎜, 5 ㎛를 사용하였다. 이동상 A는 아세토니트릴, 이동상 B는 0.05 % 트리클로로아세틱에시드(Trichloroacetic acid, TFA)를 사용하였다. 유량은 1 mL/min로 하고, 주입량은 100 μL로 하였다. 검출한계는 5 ㎍/L이다. 실험 결과 자외선/염소에서 pH 7.0 조건에서 MC-LR의 90 % 제거를 위해 필요한 CT 값은 128 ㎎/L·min으로 나타났고, 90 % 제거를 위해서는 자외선 조사량이 1,000 mJ/㎠ 이상이 필요한 것으로 나타났다. 자외선/H<sub>2</sub>O<sub>2</sub>에서 pH 7.0 조건의 경우 90 % 제거를 위해 필요한 자외선 조사량은 650 mJ/㎠으로 나타났고, 과산화수소 주입량은 0.3 ㎎/L로 나타났다.

      • KCI등재

        정수공정에서 유기물 모니터링을 위한 Fluorescence EEM의 적용

        남숙현 ( Sookhyun Nam ),이주원 ( Juwon Lee ),김은주 ( Eunju Kim ),구재욱 ( Jaewuk Koo ),황태문 ( Tae-mun Hwang ) 한국수처리학회 2020 한국수처리학회지 Vol.28 No.3

        Natural organic matter (NOM) is a substance that affects performance in the water treatment process that is crucial to understand. NOM can have different composition according to environmental changes. In this study, we applied the fluorescence excitation emission matrices-parallel factor analysis (FEEM-PARAFAC) method for characterizing dissolved organic matter (DOM). This method provides valuable insight into the chemical composition of DOM and the effects of various treatment processes in engineered systems. This study was conducted on raw water, coagulation/sedimentation, sand filtration, and activated carbon in N water treatment. The correlation between the component and the process was derived by PARAFAC with 100 fluorescence spectra. Using this method, components correlated with the DOM removal for water process were derived. It was determined, C1 (E<sub>x</sub>/E<sub>m</sub> = 250(350)/450) is the main component to monitor the removal rates of DOM in the flocculation/sedimentation process, the C1/C2 fraction (E<sub>x</sub>/E<sub>m</sub> = 250(325)/400) is the main component in the sand filter process, and C2 (E<sub>x</sub>/E<sub>m</sub> = 250(325)/400) is the main component in the activated carbon process. It has been found to be a suitable tool to track the change of organic matter quantity and quality in water treatment processes.

      • KCI등재

        자외선/염소 및 자외선/과산화수소 기술에 의한 Microcystin-LR 처리 특성 비교

        남숙현 ( Sookhyun Nam ),이주원 ( Joowun Lee ),김은주 ( Eunju Kim ),구재욱 ( Jaewuk Koo ),황태문 ( Tae-mun Hwang ) 한국수처리학회 2022 한국수처리학회지 Vol.30 No.5

        Microcystin-LR (MC-LR), the most widely known toxin produced in cyanobacteria, is problematic because of its toxicity. This study was carried out to evaluate the capability of ultraviolet photolysis of chlorine(UV/Cl<sub>2</sub>) and ultraviolet photolysis of hydrogen peroxide(UV/H<sub>2</sub>O<sub>2</sub>). Results showed that direct photolysis with 254 nm UV irradiation achieved substantial toxin removal. In particular, in UV/Cl<sub>2</sub> oxidation treatment, the removal rate of MC-LR was improved through various radical reactions that were similar to UV/H<sub>2</sub>O<sub>2</sub>. In the UV/chlorine process at the pH of 7.0, UV irradiation amount of100 mJ/cm<sup>2</sup> and chlorine concentration of 0.3 mg/L, the MC-LR removal rate was 52.0%, indicating that the removal rate was increased by 24% compared to the UV only treatment. In the UV/chlorine and UV/H<sub>2</sub>O<sub>2</sub> process at pH 7.0, the first-order degradation rate constants of MC-LR were 3.1×10<sup>-3</sup>~3.6×10<sup>-3</sup> s<sup>-1</sup> and 2.9×10<sup>-3</sup>~3.7×10<sup>-3</sup> s<sup>-1</sup>, respectively. It was shown that the degradation rate constant of MC-LR was lowered by 19.4% at pH 9.0 compared to that of pH 7.0, where the analysis found that the change in pH affected oxidation ability. UV/H<sub>2</sub>O<sub>2</sub> was not affected by pH. This result affects the energy consumption needed to meet the required 90% elimination of MC-LR.

      • KCI등재

        먹는물의 미생물 실시간 감시를 위한 온라인 ATP 측정법의 적용

        남숙현 ( Sookhyun Nam ),황태문 ( Tae-mun Hwang ),김은주 ( Eunju Kim ),안주석 ( Jooseok An ),구재욱 ( Jae-wuk Koo ),이주원 ( Joowun Lee ) 한국수처리학회 2021 한국수처리학회지 Vol.29 No.5

        The evaluation of microbial contamination in drinking water is a major concern worldwide. Adenosine triphosphate (ATP) monitoring can serve as a complement to the HPC method currently used for water quality tests because it offers rapid measurement, ease of use, and activity against microorganisms. In this study, we proposed an alternative to in situ rapid microbial monitoring methods. The ATP levels in tap water and surface-treated water were monitored using an online ATP analyzer. The ATP level of the surface-treated water was three times higher than that of the tap water. Furthermore, the correlation between E. coli and ATP confirmed that if the number of microorganisms in water is small, the ATP data must be obtained according to the target water characteristics to enable the monitoring for microbial viability in drinking water. For effective E. coli monitoring, online ATP data was stored in its own server database and an internet-of-things (IoT)-based microbial monitoring system was established and successfully applied. Recent advances in the ATP technology and IoT technology have enabled the quick and accurate online monitoring of the ATP level in water. This helps in maintaining the microbial stability of drinking water by detecting the signs of its microbial contamination early and to process it as quickly as possible.

      • UV-LED/chlorine 기술에 의한 맛·냄새 유발물질 및 미량유기물질 제거

        이주원 ( Joowon Lee ),남숙현 ( Sookhyun Nam ),구재욱 ( Jae-wuk Koo ),김은주 ( Eun Ju Kim ),황태문 ( Tae-mun Hwang ) 한국물환경학회 2020 한국물환경학회·대한상하수도학회 공동 춘계학술발표회 Vol.2020 No.-

        맛, 냄새 유발물질은 표준정수처리 방법으로는 처리가 어렵기 때문에 이를 제거하기 위해서는 고도처리가 필요하다. 그 중 고도산화공정(Advanced Oxidation Process, AOP)은 UV, H2O2, O3 등을 사용하여 라디칼 물질을 발생시켜 유기물을 제거하는 방법으로, 난분해성 유기물 제거에 효과적인 방법으로 각광받고 있다. 본 연구는 기존 UV 램프를 대신하여 UV/LED를 사용하였으며, 255 ㎚와 285 ㎚에서 파장에 의한 맛, 냄새물질 제거율을 비교하였다. 대부분의 연구에서 대상 맛, 냄새 유발 물질로 Geosmin과 2-methylisoborneol(2-MIB)를 사용하는데 본 연구에서는 2,4,6-trichloanisole(TCA), 2-isopropyl-3-methoxypyrazine(IPMP), 2-isobutyl-3-methoxypyrazine(IBMP)를 대상 물질로 선정하여 실험을 진행하였다. 이 물질들은 식수로 사용되는 자연수에서 주로 발생하며 이들 물질은 공중보건에 직접적인 영향을 끼치지는 않지만, ng/L의 낮은 역치를 가지며 미각과 악취 문제를 발생시킨다. 대상 물질을 정량화하기 위해 SPME-GC/MS 방법을 사용하였다. 분석은 GC/MS(TraceGC ultra/Polaris Q, Thermo, USA)와 Autosampler(TriPLUS AS, Thermo, USA)를 사용하였다. SPME Fiber는 50/30 ㎛ Stable flex divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) (Supelco, Bellfonte, USA)를 사용하였다. 시료는 N 정수장 모래여과수에 pH는 7과 9로 조정하여 각각의 맛, 냄새 물질을 100 ㎍/L로 제조하여 사용하였다. UV-LED 직접조사와 UV-LED/염소의 두 가지 방법에서 맛, 냄새 물질의 제거를 비교하였다. LED 조사장치는 PearlBeam(TM) Collimated Beam Device(AquiSense Technologies, USA)를 사용하였다. 맛, 냄새 유발물질의 제거 기작과 UV-LED 공정에서의 분해정도를 분석하기 위하여 LED 강도, pH, 염소 주입량을 달리하여 다양한 조건에서 실험을 진행하였다. LED 파장은 255 ㎚, 285 ㎚로 하였고 UV-LED에서 자외선 조사량은 0, 400, 600 및 1000 mJ/㎠로 조절하였으며, 염소 농도는 0, 1.2, 2.5, 5 ㎎/L로 주입하여 비교 분석하였다. 실험 결과 UV-LED/염소에서 pH 7, 염소 주입량 1.2 ㎎/L의 조건에서 파장 255 ㎚는 IPMP, IBMP, TCA에 대해 각각 22 %, 31 %, 45 %의 제거율을 보였으며, 파장 285 ㎚는 각각 35 %, 52 %, 56 %의 제거율을 보였다. IPMP, IBMP, TCA 물질 파장 255 ㎚ 조건보다 파장 285 ㎚에서 제거율이 10 % 정도 높은 것으로 나타났다. 고농도의 염소 주입 조건에서는 더 높은 제거율을 보였으며 UV를 사용한 실험과 비슷한 효율을 얻을 수 있을지는 추후 연구를 통해 규명할 것이다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼