박종민(J.M. Park),서성원(S.W. Suh),권영국(Y.G. Kwon),박주범(J.B. Park),김현우(H.W. Kim),김건태(G.T. Kim) 대한전기학회 2010 대한전기학회 학술대회 논문집 Vol.2010 No.7
This paper presents a series of processes of designing, manufacturing and testing of AC 22.9㎸ three core XLPE submarine cables with optical fiber unit. To verify the mechanical performance of the submarine cables, CAE (Computer Aided Engineering) method have been applied to structural design of the submarine cable and the corresponding mechanical tests have been performed.