http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Lilian de Siqueira,Verônica Ribeiro dos Santos,Juliani Caroline Ribeiro de Araújo,Hugo Gutemberg Patiño de Oliveira Filho,Luana Marotta Reis de Vasconcellos,Eliandra de Sousa Trichês,Alexandre Luiz So 한국섬유공학회 2023 Fibers and polymers Vol.24 No.9
The development of new biomaterials with improved properties is a trend in tissue regeneration. In this way, an innovative approach is employed in this work for obtaining polymer fibers coated with nanoparticles resulting from the simultaneous application of poly (lactic acid) (PLA)/polycaprolactone (PCL) electrospinning and bioactive particles from an amorphous multicomponent silica–calcium–phosphorus system (AMS) electrospraying. The osteogenesis was evaluated in vitro and in vivo using male rats, in which total protein, alkaline phosphatase, and biological performance through histological and histomorphometric analysis were discussed. The morphological results assessed by scanning electron microscopy showed a mesh of PLA/PCL fibers associated with AMS. The spraying of 17.44% of AMS particles in the PLA/PCL electrospun fibers decreased the Young’s modulus and tensile strength. However, the amount of AMS particles sprayed was enough to promote a reduction of 17.8% in the measured contact angle values. Phosphatase alkaline higher mean value was also observed in the fibers when in contact with the AMS, but nonstatistical difference was observed (p > 0.05). It was possible to observe the presence of mineralized nodules deposited on the bottom of the plate and between the fibers. The newly formed bone into defect filled with PLA/PCL-AMS fibers was higher than that observed in the control group. These findings suggest PLA/PCL-AMS fibers as a multifunctional composite system that may be attractive for both bone and dental tissue engineering applications.
Oliveira, Livia Maria Lopes de,Souza, Camila Agra,Cunha, Sinara,Siqueira, Rafael,Vajgel, Bruna de Carvalho Farias,Cimoes, Renata Korean Academy of Periodontology 2021 Journal of Periodontal & Implant Science Vol.51 No.-
Purpose: This systematic review aimed to compare the efficacy, defined in terms of the mean percentage of root coverage (mRC), of surgical treatment approaches combined with adhesive restorations of non-carious cervical lesions (NCCLs) to that of root coverage alone in patients with a single gingival recession (GR) and NCCL. Methods: A literature search was conducted to identify longitudinal studies reporting the mRC following treatment for the correction of GR defects associated with NCCLs using a combination of surgical and restorative techniques in systemically and periodontally healthy patients. Results: The search resulted in the retrieval of 12,409 records. Seven publications met the inclusion criteria for the qualitative synthesis of data. The mRCs ranged from 69% to 97%. In the medium term, the gingival margin position was more stable when a connective tissue graft (CTG) was used, independently of whether restoration of teeth with NCCLs was performed. Conclusions: The strength of the evidence was limited by methodological heterogeneity in terms of study design as well as the unit and period of analysis, which precluded a metaanalysis. Although no definitive conclusion could be drawn due to the lack of sufficient evidence to estimate the effectiveness of the interventions, CTG-based procedures contributed to gingival margin stability regardless of the performance of restoration to treat NCCLs.
Lívia Maria Lopes de Oliveira,Camila Agra Souza,Sinara Cunha,Rafael Siqueira,Bruna de Carvalho Farias Vajgel,Renata Cimões 대한치주과학회 2022 Journal of Periodontal & Implant Science Vol.52 No.2
Purpose: This systematic review aimed to compare the efficacy, defined in terms of the mean percentage of root coverage (mRC), of surgical treatment approaches combined with adhesive restorations of non-carious cervical lesions (NCCLs) to that of root coverage alone in patients with a single gingival recession (GR) and NCCL. Methods: A literature search was conducted to identify longitudinal studies reporting the mRC following treatment for the correction of GR defects associated with NCCLs using a combination of surgical and restorative techniques in systemically and periodontally healthy patients. Results: The search resulted in the retrieval of 12,409 records. Seven publications met the inclusion criteria for the qualitative synthesis of data. The mRCs ranged from 69% to 97%. In the medium term, the gingival margin position was more stable when a connective tissue graft (CTG) was used, independently of whether restoration of teeth with NCCLs was performed. Conclusions: The strength of the evidence was limited by methodological heterogeneity in terms of study design as well as the unit and period of analysis, which precluded a metaanalysis. Although no definitive conclusion could be drawn due to the lack of sufficient evidence to estimate the effectiveness of the interventions, CTG-based procedures contributed to gingival margin stability regardless of the performance of restoration to treat NCCLs.
Yamamoto-Silva, Fernanda Paula,de Oliveira Siqueira, Claudeir Felipe,Silva, Maria Alves Garcia Santos,Fonseca, Rodrigo Borges,Santos, Ananda Amaral,Estrela, Carlos,de Freitas Silva, Brunno Santos Korean Academy of Oral and Maxillofacial Radiology 2018 Imaging Science in Dentistry Vol.48 No.3
Purpose: This study was performed to evaluate the influence of voxel size and the accuracy of 2 cone-beam computed tomography (CBCT) systems in the detection of vertical root fracture (VRF) in the presence of intracanal metallic posts. Materials and Methods: Thirty uniradicular extracted human teeth were selected and randomly divided into 2 groups(VRF group, n=15; and control group, n=15). The VRFs were induced by an Instron machine, and metallic posts were placed in both groups. The scans were acquired by CBCT with 4 different voxel sizes: 0.1 mm and 0.16 mm (for the Eagle 3D V-Beam system) and 0.125 mm and 0.2 mm (for the i-CAT system) (protocols 1, 2, 3, and 4, respectively). Interobserver and intraobserver agreement was assessed using the Cohen kappa test. Sensitivity and specificity were evaluated and receiver operating characteristic analysis was performed. Results: The intraobserver coefficients indicated good (0.71) to very good (0.83) agreement, and the interobserver coefficients indicated moderate (0.57) to very good (0.80) agreement. In respect to the relationship between sensitivity and specificity, a statistically significant difference was found between protocols 1 (positive predictive value: 0.710, negative predictive value: 0.724) and 3 (positive predictive value: 0.727, negative predictive value: 0.632) (P<.05). The least interference due to artifact formation was observed using protocol 2. Conclusion: Protocols with a smaller voxel size and field of view seemed to favor the detection of VRF in teeth with intracanal metallic posts.
Fernanda Paula Yamamoto-Silva,Claudeir Felipe de Oliveira Siqueira,Maria Alves Garcia Santos Silva,Rodrigo Borges Fonseca,Ananda Amaral Santos,Carlos Estrela,Brunno Santos de Freitas Silva 대한영상치의학회 2018 Imaging Science in Dentistry Vol.48 No.3
Purpose: This study was performed to evaluate the influence of voxel size and the accuracy of 2 cone-beam computed tomography (CBCT) systems in the detection of vertical root fracture (VRF) in the presence of intracanal metallic posts. Materials and Methods: Thirty uniradicular extracted human teeth were selected and randomly divided into 2 groups (VRF group, n=15; and control group, n=15). The VRFs were induced by an Instron machine, and metallic posts were placed in both groups. The scans were acquired by CBCT with 4 different voxel sizes: 0.1 mm and 0.16 mm (for the Eagle 3D V-Beam system) and 0.125 mm and 0.2 mm (for the i-CAT system) (protocols 1, 2, 3, and 4, respectively). Interobserver and intraobserver agreement was assessed using the Cohen kappa test. Sensitivity and specificity were evaluated and receiver operating characteristic analysis was performed. Results: The intraobserver coefficients indicated good (0.71) to very good (0.83) agreement, and the interobserver coefficients indicated moderate (0.57) to very good (0.80) agreement. In respect to the relationship between sensitivity and specificity, a statistically significant difference was found between protocols 1 (positive predictive value: 0.710, negative predictive value: 0.724) and 3 (positive predictive value: 0.727, negative predictive value: 0.632) (P<.05). The least interference due to artifact formation was observed using protocol 2. Conclusion: Protocols with a smaller voxel size and field of view seemed to favor the detection of VRF in teeth with intracanal metallic posts.