RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Radiation exposure during different percutaneous renal puncture techniques: A YAU endourology & urolithiasis study

        Tarik Emre Sener,Yiloren Tanidir,Serap Ketenci,Umut Kutukoglu,Dogancan Dorucu,Huseyin Cayir,Amelia Pietropaolo,Esteban Emiliani,Bhaskar Somani 대한비뇨의학회 2023 Investigative and Clinical Urology Vol.64 No.5

        Purpose: Radiation exposure is affected by C-arm fluoroscopy device positioning during percutaneous renal puncture. Our aim was to compare the exposure of surgeon's lens, hand and chest with a fluoroscopy protocol replicated in different C-arm positions. Materials and Methods: A standardized fluoroscopy protocol was created using water-equivalent solid phantoms to replicate a surgeon and patient. 111 mGy radiation (360 s) was applied in standard fluoroscopy mode (91 kVp, 2.7 mA/mAs). Dosimeters were placed on lens, chest and hand of surgeon and patient phantom models. 7 different C-arm positions were created: 0°, mediolateral (ML) +90°, ML -90°, ML +30°, ML -15°, craniocaudal (CC) +30°, CC +15°. Measurements were evaluated separately for different positions. Results: The highest radiation exposure was measured on patient dosimeter (2.97 mSv). The highest exposure on surgeon was recorded on finger dosimeter in all C-arm positions; highest dose was recorded in ML +90° position (2.88 mSv). In finger dosimeters, lowest exposure was recorded in 0° position (0.51 mSv). The lowest exposure of all positions was measured in chest dosimeter in ML -90° position (0.24 mSv). Conclusions: In positions where X-ray generator of the C-arm was facing towards the surgeon, radiation exposure measured in all dosimeters was higher compared to positions where the generator was facing away. The hand radiation exposure in all positions was higher than chest and lens. Special care must be taken to avoid facing the X-ray generator tube and hands should be as well-protected as chest and eyes with special protective gear.

      • KCI등재

        Thulium laser vaporesection of the prostate: Can we operate without interrupting oral antiplatelet/ anticoagulant therapy?

        Tarik Emre Sener,Salvatore Butticè,Luciano Macchione,Christopher Netsch,Yiloren Tanidir,Laurian Dragos,Rosa Pappalardo,Carlo Magno 대한비뇨의학회 2017 Investigative and Clinical Urology Vol.58 No.3

        Purpose: Thulium vaporesection of the prostate (ThuVARP) is a new and safe approach for patients receiving anticoagulant therapy in whom transurethral resection of the prostate (TURP) may possess a high bleeding risk. We aimed to demonstrate the efficacy and safety of ThuVARP in patients receiving oral antiplatelet/anticoagulant (OAP/OAC) therapy. Materials and Methods: A total of 103 patients who underwent ThuVARP between 2011 and 2013 were enrolled in the study. Patients were divided into 2 groups. Group A consisted of 47 patients who underwent low molecular weight heparin (LMWH) bridging and group B consisted of 56 patients who were operated on while receiving OAP/OAC therapy. Results: The drop in hemoglobin levels in the pre- and postoperative periods was significantly higher in group A than in group B. When subgroups were analyzed, the mean drop in hemoglobin was significantly lower in the warfarin and ticlopidine subgroups of group B than in group A. International Prostate Symptom Scores were significantly lower 3, 12, 18, and 24 months after surgery in group A than in group B. Quality of life scores, maximal flow rate values, and postmicturition residual urine volumes (mL) were similar between the 2 groups. A total of 38 and 41 patients in groups A and B, respectively, had no complications. Conclusions: Our study showed the safety profile of continuing different OAP/OAC therapies in terms of bleeding problems in patients undergoing ThuVARP. We strongly recommend abandoning LMWH bridging and maintaining the OAP/OAC regimen patients are already receiving.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼