RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        A Reagent-Ready-on-Chip Microfluidic Immunoassay System for Rapid Detection of Influenza A H1N1 and H3N2 Viruses

        Kin Fong Lei,Jun-Liang Liu,Chia-Hao Huang,Rei-Lin Kuo,Ngan-Ming Tsang 한국바이오칩학회 2016 BioChip Journal Vol.10 No.1

        Development of effective disease screening method is the best approach for the control of infectious diseases. However, conventional screening methods require to operate in well-equipped laboratory. That makes the screening operation expensive and time-consuming. In this work, a reagent-ready-on-chip microfluidic immunoassay system was developed and rapid detection of influenza A H1N1 and H3N2 viruses was demonstrated to show its simplicity and rapidity. The microfluidic system integrated 4 single-stroke thermopneumatic actuators and a reaction chamber. All related reagents were pre-installed in the system and manipulated automatically for indirect immunoassay. Detection of influenza A H1N1 and H3N2 viruses based on its internal structure protein, i.e., nucleoprotein (NP), was demonstrated using the system. Result was represented by colorimetric signal in the reaction chamber. The use of thermopneumatic actuation could achieve fluid manipulation without external assistive equipment and colorimetric result could be observed directly without the need of external dedicated detector. Influenza virus screening could be completed around 1 hour with less sample volume (20 μL) and reagent volume (50 μL). The system achieved one-step operation of immunoassay. It is highly integrated and has potential to be developed to portable devices to realize rapid diagnostics in remote environment and clinics without well-equipped facility. Development of effective disease screening method is the best approach for the control of infectious diseases. However, conventional screening methods require to operate in well-equipped laboratory. That makes the screening operation expensive and time-consuming. In this work, a reagent-ready-on-chip microfluidic immunoassay system was developed and rapid detection of influenza A H1N1 and H3N2 viruses was demonstrated to show its simplicity and rapidity. The microfluidic system integrated 4 single-stroke thermopneumatic actuators and a reaction chamber. All related reagents were pre-installed in the system and manipulated automatically for indirect immunoassay. Detection of influenza A H1N1 and H3N2 viruses based on its internal structure protein, i.e., nucleoprotein (NP), was demonstrated using the system. Result was represented by colorimetric signal in the reaction chamber. The use of thermopneumatic actuation could achieve fluid manipulation without external assistive equipment and colorimetric result could be observed directly without the need of external dedicated detector. Influenza virus screening could be completed around 1 hour with less sample volume (20 μL) and reagent volume (50 μL). The system achieved one-step operation of immunoassay. It is highly integrated and has potential to be developed to portable devices to realize rapid diagnostics in remote environment and clinics without well-equipped facility.

      • KCI등재후보

        Shear behavior of reinforced HPC beams made of a low cement content without shear reinforcements

        Chao-Wei Tang,Yu-Ping Chen,How-Ji Chen,Chung-Ho Huang,Tsang-Hao Liu 사단법인 한국계산역학회 2013 Computers and Concrete, An International Journal Vol.11 No.1

        High-performance concrete (HPC) usually has higher paste and lower coarse aggregate volumes than normal concrete. The lower aggregate content of HPC can affect the shear capacity of concrete members due to the formation of smooth fractured surfaces and the subsequent development of weak interface shear transfer. Therefore, an experimental investigation was conducted to study the shear strength and cracking behavior of full-scale reinforced beams made with low-cement-content high-performance concrete (LcHPC) as well as conventional HPC. A total of fourteen flexural reinforced concrete (RC) beams without shear reinforcements were tested under a two-point load until shear failure occurred. The primary design variables included the cement content, the shear span to effective depth ratio (a/d), and the tensile steel ratio (ρw). The results indicate that LcHPC beams show comparable behaviors in crack and ultimate shear strength as compared with conventional HPC beams. Overall, the shear strength of LcHPC beams was found to be larger than that of corresponding HPC beams, particularly for an a/d value of 1.5. In addition, the crack and ultimate shear strength increased as a/d decreased or ρw increased for both LcHPC beams and HPC beams. This investigation established that LcHPC is recommendable for structural concrete applications.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼