        Comparison of the Minimum Plateau Width by Plateau and a New Method in People with Conductive Hearing Loss

        Seyyed Jalal Sameni,Ahmad Daneshi,Akram Pourbakht,Aliakbar Tahaei,Mohammad Kamali 대한청각학회 2018 Journal of Audiology & Otology Vol.22 No.4

        Background and Objectives: In clinical masking, the plateau is a state in which the non-test ear (NTE) is completely masked by the noise and tone is heard only by the test ear (TE). At least 15 to 20 dB of plateau width is needed to obtain valid threshold. In the study, a part of plateau after initial masking level known as the minimum plateau width (mPW) was determined and compared by a new formula and the plateau searching method. Subjects and Methods: Minimum plateau widths of air conduction were obtained in 29 participants with unilateral and 30 participants with bilateral conductive hearing loss (CHL) aged 20 to 45 years old by using step by step plateau method and mPW estimation by the formula between two points of masking diagram [mPW=(N2-N1)-(T2-T1)] and then the mPW of twomethods was compared for each frequency. Results: There was no significant difference between the minimum plateau width obtained by the plateau and formula methods for two given point of masking diagram in people with unilateral and bilateral CHL at octave frequencies from 500 Hz to 4,000 Hz. Conclusions: Threshold obtaining of TE by two tones for two noise levels delivered to the NTE is enough to estimate the mPW between these two noise points and it is not necessary that for clinicians to know the actual values of masking diagram components.

      • KCI등재

        Satisfaction with Hearing Aids among Aged Patients with Different Degrees of Hearing Loss and Length of Daily Use

        Rezvan Dashti,Farzad Faraji Khiavi,Seyyed Jalal Sameni,Arash Bayat 대한청각학회 2015 Journal of Audiology & Otology Vol.19 No.1

        Background and Objectives: The evaluation of subjective benefits and positive effects of hearing aids in daily is important for measuring the treatment outcome. The aim of this project was to investigate the degree of satisfaction of aged users with their hearing aids using the Satisfaction with Amplification in Daily Life (SADL) scale, which emphasizes non-auditory factors contributing to satisfaction as well as benefit. Subjects and Methods: The Persian version of SADL scale was completed by 40 patients who received monaural hearing aid fitting at south of the Iran from December 2013 and March 2014. SADL subscales of the SADL were evaluated according to the type and degree of hearing loss, the pure tone audiogram pattern and shape and type of the hearing aid. Results: The results associated with the SADL subscales revealed a greater satisfaction associated with the Positive Effect and Service and Costs subscales. Subjects with different degree of hearing loss were very satisfied in terms of positive effect subscale. Conclusions: Participants reported a considerable level of satisfaction with their hearing aids. Appropriate guidance for using hearing aids and spending more time for counseling can improve the satisfaction level of this age group.

      • KCI등재

        Horizontal Localization in Simulated Unilateral Hearing Loss

        Anvarsamarein Parisa,Nazeri Ahmad Reza,Sameni Seyyed Jalal,Kamali Mohammad,Zarrin Koob Homa 대한청각학회 2018 Journal of Audiology & Otology Vol.22 No.1

        Background and Objectives: The ability to localize a sound source is one of the binauralhearing benefits in a horizontal plane based on interaural time difference and interaural intensitydifference. Unilateral or bilateral asymmetric hearing loss will affect binaural hearing and leadto sound locating errors. In this cross sectional analytical descriptive study, the localization errorwas investigated when participants turned their heads to the sound source with closedeyes and after simulating unilateral hearing loss by placing earplugs inside the right ear canal. Subjects and Methods: This cross sectional analytical descriptive study was carried out on30 right-handed adults, 22 female and 8 male (average: 25 years, standard deviation: 3.16). They were selected with the available random access method. Horizontal localization wasevaluated with five speakers located at 0, ±30, and ±60 degree azimuths at a 1-meter distancefrom the examinee. Narrow-band noise signals were delivered at 35 dB SL in two “withoutearplug” and “with earplug” situations and the results were compared. The study was performedbetween September and December 2016 in Tehran, Iran. Results: Significantdifferences were observed in localization errors between the “with earplug” and “without earplug”situations. The localization differences were greater for left-side speakers (-30 and -60degrees) compared with right-side speakers (+30 and +60 degrees). The differences weremore apparent at 4,000 and 6,000 Hz, which confirmed the effect of unilateral simulatedhearing loss on interaural latency differences. Conclusions: Simulating hearing loss by usingan earplug in one ear (right) increased localization errors at all frequencies. The errorsincreased at higher frequencies.