RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Experimental and Thermal Analysis of Solar Thermoelectric System Performance Incorporated with Solar Tracker

        Tahsin Atalay,Yusuf Yakut,Yavuz Köysal,Seyda Özbektaş,Hakan Bülbül,Bahattin Topaloğlu 한국정밀공학회 2022 International Journal of Precision Engineering and Vol.9 No.2

        In this study, it is aimed to determine the energy generation capability of the designed and manufactured thermoelectric system when mounted on the two-axis solar tracking system. Thus, it was possible to compare the results obtained from current study with previous study. The system used in previous study was comprised of a thermoelectric generator (TEG) for energy conversion, a linear Fresnel lens for concentrating solar rays, and a one-axis tracking system to increase the electrical and thermal efficiency of the system. In this study, a dual-axis (two-axis) tracking system was used as a tracking system to examine the change in thermal and electrical efficiency. Therefore, experimental measurements were performed again using both two-axis and one-axis solar tracking systems on 16th October 2019 and 17th October 2019, respectively, at the location which falls at 41°14′ N and 36°26′ E. Additionally, the heat transfer and electricity generation performance of TEG was theoretically analyzed using CFD model. For this purpose, a numerical model consisting TEG with heat sink was developed. It was observed that the model data obtained and the experimental data were in good agreement. The values of parameters such as temperature, solar radiation, wind speed and TEG open circuit voltage were measured instantaneously during the measurements. The maximum open circuit voltages obtained is 1.02 and 1.13 V for one-axis and dual-axis systems, respectively. The solar radiation values were measured as 464 and 472 W∕m2 , respectively when the maximum open circuit voltages value is obtained. The duration for measurements was kept about 15 min so that the average values of these parameters were used in calculations. Thus, the values of maximum output power ( P maxout) , electrical efficiency (ηe) and Seebeck coefficient ( TEG) were calculated and given in the paper.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼