RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

        Rumpa Ganguly,Aruna Ramesh,Sarah Pagni 대한영상치의학회 2016 Imaging Science in Dentistry Vol.46 No.2

        Purpose: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Materials and Methods: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view (13 cm×16 cm) and small field of view (5 cm×8 cm) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. Results: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. Conclusion: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.

      • SCOPUSKCI등재

        The accuracy of linear measurements of maxillary and mandibular edentulous sites in conebeam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

        Ganguly, Rumpa,Ramesh, Aruna,Pagni, Sarah Korean Academy of Oral and Maxillofacial Radiology 2016 Imaging Science in Dentistry Vol.46 No.2

        Purpose: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Materials and Methods: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view ($13cm{\times}16cm$) and small field of view ($5cm{\times}8cm$) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. Results: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. Conclusion: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.

      • SCOPUSKCI등재

        Interactive learning in oral and maxillofacial radiology

        Ramesh, Aruna,Ganguly, Rumpa Korean Academy of Oral and Maxillofacial Radiology 2016 Imaging Science in Dentistry Vol.46 No.3

        Purpose: The use of electronic tools in teaching is growing rapidly in all fields, and there are many options to choose from. We present one such platform, Learning Catalytics$^{TM}$ (LC) (Pearson, New York, NY, USA), which we utilized in our oral and maxillofacial radiology course for second-year dental students. Materials and Methods: The aim of our study was to assess the correlation between students' performance on course exams and self-assessment LC quizzes. The performance of 354 predoctoral dental students from 2 consecutive classes on the course exams and LC quizzes was assessed to identify correlations using the Spearman rank correlation test. The first class was given in-class LC quizzes that were graded for accuracy. The second class was given out-of-class quizzes that were treated as online self-assessment exercises. The grading in the self-assessment exercises was for participation only and not accuracy. All quizzes were scheduled 1-2 weeks before the course examinations. Results: A positive but weak correlation was found between the overall quiz scores and exam scores when the two classes were combined (P<0.0001). A positive but weak correlation was likewise found between students' performance on exams and on in-class LC quizzes (class of 2016) (P<0.0001) as well as on exams and online LC quizzes (class of 2017) (P<0.0001). Conclusion: It is not just the introduction of technological tools that impacts learning, but also their use in enabling an interactive learning environment. The LC platform provides an excellent technological tool for enhancing learning by improving bidirectional communication in a learning environment.

      • KCI등재

        Interactive learning in oral and maxillofacial radiology

        Aruna Ramesh,Rumpa Ganguly 대한영상치의학회 2016 Imaging Science in Dentistry Vol.46 No.3

        Purpose: The use of electronic tools in teaching is growing rapidly in all fields, and there are many options to choose from. We present one such platform, Learning CatalyticsTM (LC) (Pearson, New York, NY, USA), which we utilized in our oral and maxillofacial radiology course for second-year dental students. Materials and Methods: The aim of our study was to assess the correlation between students’ performance on course exams and self-assessment LC quizzes. The performance of 354 predoctoral dental students from 2 consecutive classes on the course exams and LC quizzes was assessed to identify correlations using the Spearman rank correlation test. The first class was given in-class LC quizzes that were graded for accuracy. The second class was given out-of-class quizzes that were treated as online self-assessment exercises. The grading in the selfassessment exercises was for participation only and not accuracy. All quizzes were scheduled 1-2 weeks before the course examinations. Results: A positive but weak correlation was found between the overall quiz scores and exam scores when the two classes were combined (P<0.0001). A positive but weak correlation was likewise found between students’ performance on exams and on in-class LC quizzes (class of 2016) (P<0.0001) as well as on exams and online LC quizzes (class of 2017) (P<0.0001). Conclusion: It is not just the introduction of technological tools that impacts learning, but also their use in enabling an interactive learning environment. The LC platform provides an excellent technological tool for enhancing learning by improving bidirectional communication in a learning environment.

      • KCI등재

        Coincidence of calcified carotid atheromatous plaque, osteoporosis, and periodontal bone loss in dental panoramic radiographs

        Aruna Ramesh,Sheila Soroushian,Rumpa Ganguly 대한영상치의학회 2013 Imaging Science in Dentistry Vol.43 No.4

        Purpose: This study was performed to assess the correlation of calcified carotid atheromatous plaque (CCAP), the mandibular cortical index, and periodontal bone loss in panoramic radiographs. Materials and Methods: One hundred eighty-five panoramic radiographs with CCAP and 234 without this finding were evaluated by 3 observers for the presence of osseous changes related to osteoporosis and periodontal bone loss. Chi-squared and Mann-Whitney U tests were used to compare the two groups for an association of CCAP with the mandibular cortical index and periodontal bone loss, respectively. Results: There was a statistically significant coincidence of CCAP and osseous changes related to osteopenia/osteoporosis, with a p-value ⁄0.001. There was no statistically significant coincidence of CCAP and periodontal bone loss. When comparing the 2 groups, “With CCAP” and “Without CCAP”, there was a statistically significant association with the mean body mass index (BMI), number of remaining teeth, positive history of diabetes mellitus, and vascular accidents. There was no statistically significant association with gender or a history of smoking. Conclusion: This study identified a possible concurrence of CCAP and mandibular cortical changes secondary to osteopenia/osteoporosis in panoramic radiographs. This could demonstrate the important role of dental professionals in screening for these systemic conditions, leading to timely and appropriate referrals resulting in early interventions and thus improving overall health.

      • SCOPUSKCI등재

        Coincidence of calcified carotid atheromatous plaque, osteoporosis, and periodontal bone loss in dental panoramic radiographs

        Ramesh, Aruna,Soroushian, Sheila,Ganguly, Rumpa Korean Academy of Oral and Maxillofacial Radiology 2013 Imaging Science in Dentistry Vol.43 No.4

        Purpose: This study was performed to assess the correlation of calcified carotid atheromatous plaque (CCAP), the mandibular cortical index, and periodontal bone loss in panoramic radiographs. Materials and Methods: One hundred eighty-five panoramic radiographs with CCAP and 234 without this finding were evaluated by 3 observers for the presence of osseous changes related to osteoporosis and periodontal bone loss. Chi-squared and Mann-Whitney U tests were used to compare the two groups for an association of CCAP with the mandibular cortical index and periodontal bone loss, respectively. Results: There was a statistically significant coincidence of CCAP and osseous changes related to osteopenia/osteoporosis, with a p-value <0.001. There was no statistically significant coincidence of CCAP and periodontal bone loss. When comparing the 2 groups, "With CCAP" and "Without CCAP", there was a statistically significant association with the mean body mass index (BMI), number of remaining teeth, positive history of diabetes mellitus, and vascular accidents. There was no statistically significant association with gender or a history of smoking. Conclusion: This study identified a possible concurrence of CCAP and mandibular cortical changes secondary to osteopenia/osteoporosis in panoramic radiographs. This could demonstrate the important role of dental professionals in screening for these systemic conditions, leading to timely and appropriate referrals resulting in early interventions and thus improving overall health.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼