RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        A novel human cadaver model to investigate a retrourethral transobturator male sling procedure

        Sean F. Mungovan,William I. Jaffe,Petra L. Graham,Manish I. Patel,Jaspreet S. Sandhu 대한비뇨의학회 2019 Investigative and Clinical Urology Vol.60 No.5

        Purpose: To develop a cadaver model for the assessment of a male transobturator male sling (retrourethral transobturator sling [RTS], AdVance™; Boston Scientific, USA) to investigate its effect on a simulated abdominal and retrograde leak point pressures (ALPP, RLPP) and the urethral pressure profile (UPP). Materials and Methods: Three fresh frozen human male cadaver specimens were obtained. A suprapubic tube was inserted into the bladder and connected to a digital manometer to measure bladder pressure. Manual suprapubic pressure was then applied to generate an increase in intraabdominal pressure and measure a simulated ALPP. Subsequent measurements of RLPP and UPP were recorded. All measurements were undertaken prior to and following insertion of a RTS. Results: The placement of the RTS consistently increased the simulated ALPP for all three cadaver specimens when compared to baseline measures. No leaks occurred at simulated ALPP's of 170 cm H2O for specimen 1, 160 cm H2O for specimen 2, and 170 cm H2O for specimen 3. There was minimal or no change in the RLPP's and UPP's following insertion of the RTS when compared to respective baseline. Conclusions: A model using fresh unfixed cadavers that incorporates a simulated measurement of ALPP is feasible for male stress urinary incontinence surgical intervention investigations.

      • KCI등재

        Daily Pad Usage Versus the International Consultation on Incontinence Questionnaire Short Form for Continence Assessment Following Radical Prostatectomy

        Antonio Tienza,Petra L. Graham,Jose E. Roble,Fernando Diez-Caballero,David Rosell,Juan I. Pascual,Manish I. Patel,Sean F. Mungovan 대한배뇨장애요실금학회 2020 International Neurourology Journal Vol.24 No.2

        Purpose: Continence assessment is an essential component of follow-up after radical prostatectomy (RP). Several methods exist to assess the severity of urinary incontinence (UI). Our study examined the relationship and degree of agreement between International Consultation on Incontinence Questionnaire Short Form (ICIQ-SF) scores and the number of pads used in a 24-hour period in the assessment of UI following RP. Methods: Continence was prospectively assessed in 746 men from a Spanish urology clinic 12 months after RP using the ICIQ-SF and pad usage. The relationship between ICIQ-SF scores and pad usage was assessed using Spearman rank correlation coefficients. The Jonckheere-Terpstra trend test was used to determine whether the ICIQ-SF score and the component question scores increased with increasing pad usage. The Bonferroni-corrected pairwise Wilcoxon rank-sum test was used to determine which pairs of pad usage levels differed. The weighted kappa was used to evaluate the agreement between pad usage levels and ICIQ-SF questions. Results: The continence rate was 82% using the “no pad usage” definition of continence versus 78% using the definition of an ICIQ-SF score of 0 (P<0.001). Strong positive correlations were observed between the number of pads and the ICIQ-SF total and component question scores (rs>0.85, P<0.001). The ICIQ-SF total and component question scores increased significantly with increasing pad usage (P<0.001). The ICIQ-SF scores (P<0.018) for all pairs of pad usage levels (0, 1, 2, or 3 or more) differed significantly. The agreement between the ICIQ-SF leakage amount question and pad usage was very good (rs=0.861, P<0.001). Conclusions: At 12 months post-RP, 24-hour pad usage was closely correlated with ICIQ-SF, although the continence rate differed depending on the definition used. Higher levels of pad usage were associated with higher questionnaire scores, more leakage, and poor quality of life (interference with everyday life).

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼